1. Product Overview
The DIGITAL Magnetic Digital Angle Gauge is a versatile measuring instrument designed for precise angle measurements in various applications. It features a clear LCD display, magnetic base, and optional laser alignment for enhanced accuracy.

Key Features:
- High-definition LCD screen for clear readings.
- High-precision chip for accurate measurements.
- Strong magnetic adsorption for secure attachment to metal surfaces.
- Optional laser alignment for extended measurement lines.
- Compact and portable design.
- Type-C USB charging.
2. Setup
2.1 Charging the Device
Before first use, ensure the device is fully charged.
- Locate the Type-C USB charging port on the side of the device.
- Connect a standard Type-C USB cable to the device and plug the other end into a suitable USB power adapter (not included).
- The battery indicator on the LCD display will show charging status.

2.2 Power On/Off
- To Power On: Short press the ON/OFF button. The LCD display will illuminate.
- To Power Off: Press and hold the ON/OFF button for approximately 3 seconds. The display will turn off.
2.3 Zero Calibration
For accurate measurements, it is recommended to calibrate the device (set zero) on a known level surface.
- Place the angle gauge on a flat, stable, and level surface.
- Short press the ZERO button. The display will show '0.00°', indicating that the current position is set as the reference zero.

3. Operating Instructions
3.1 Basic Angle Measurement
- Power on the device.
- Attach the angle gauge firmly to the surface you wish to measure. Use the magnetic base for metal surfaces.
- Read the digital angle directly from the LCD display. The display shows the angle relative to the set zero point or absolute to gravity.
3.2 Laser Operation (for laser models)
The laser function provides a visual line for alignment and extension of measurement.
- After powering on the device, short press the ON/OFF button once to activate the laser on one side (e.g., right side).
- Press the ON/OFF button again to activate the laser on the other side (e.g., left side).
- Press the ON/OFF button a third time to activate both lasers simultaneously.
- Press the ON/OFF button again to turn off the lasers.
3.3 Hold Function
To freeze the current reading on the display:
- Press the Tilt% HOLD button. The reading will be held.
- Press the Tilt% HOLD button again to release the hold and resume live measurement.
3.4 Measurement Modes
The device supports both relative and absolute angle measurements, and can measure horizontal, vertical, and slope angles.

4. Maintenance
- Cleaning: Wipe the device with a soft, dry cloth. Do not use abrasive cleaners, solvents, or harsh chemicals, as these may damage the display or casing.
- Storage: Store the angle gauge in a dry place, away from direct sunlight, extreme temperatures, and high humidity.
- Protection: Avoid dropping the device or subjecting it to strong impacts. While the device is designed to be water-resistant, prevent prolonged exposure to water or submersion.
- Battery Care: Recharge the device when the battery indicator is low to ensure optimal performance and longevity of the battery.

5. Troubleshooting
- Device Not Turning On:
- Ensure the device is charged. Connect it to a Type-C USB charger and allow it to charge for at least 30 minutes before attempting to power on again.
- Inaccurate Readings:
- Re-calibrate the device by performing a zero-setting on a known level surface.
- Ensure the device is firmly attached and stable during measurement. Any movement or vibration can affect accuracy.
- Check for any obstructions or debris between the device's base and the measurement surface.
- Laser Not Working (for laser models):
- Ensure the device is powered on.
- Follow the laser operation instructions (Section 3.2) to activate the laser. Repeated presses of the ON/OFF button cycle through laser modes.
- Check battery level; low battery might affect laser performance.
6. Specifications
| Feature | Description |
|---|---|
| Product Type | Magnetic Digital Angle Finder, Electronic Level, Digital Protractor |
| Display | High-definition LCD Display |
| Power Source | Rechargeable via Type-C USB |
| Dimensions (Approx.) | 61mm (Width) x 61mm (Height) x 31mm (Depth) |
| Weight (Approx.) | 0.16 kg (160 grams) |
| Measurement Functions | Relative & Absolute Angle, Horizontal, Vertical, Slope Measurement, Zero Setting |
| Special Features | Strong Magnetic Base, Optional Laser Alignment, Water-Resistant, Auto Power-Off (3 minutes inactivity) |
| Origin | Mainland China |

7. User Tips
- Always ensure the device is fully charged before critical measurements to avoid interruptions.
- For best accuracy, perform a zero-setting calibration on a perfectly level surface before starting your work.
- When using the magnetic base, ensure the metal surface is clean and free of debris for a secure hold and accurate readings.
- Confirm whether your model includes the laser function before use, as there are variants without it.
8. Warranty & Support
For detailed warranty information, please refer to the terms provided by your retailer or the manufacturer at the time of purchase. Keep your proof of purchase for any warranty claims.
For further detailed instructions and multilingual guides, you can refer to the official user manual PDF: