Hantek DSO2090

Contents

Hantek DSO2090 Portable USB PC Digital Oscilloscope User Manual

Model: DSO-2090

1. Introduction

The Hantek DSO2090 is a portable, dual-channel USB PC digital oscilloscope designed for a wide range of electrical measurement and analysis tasks. It connects to your computer via a USB 2.0 interface, drawing power directly from the USB port, making it highly convenient for field use, product line maintenance, and educational purposes. This manual provides essential information for setting up, operating, and maintaining your DSO2090 oscilloscope.

2. Features

  • Dual Channel, 40MHz Bandwidth.
  • 100MS/s Real-time Sample Rate.
  • USB 2.0 interface, no external power source required.
  • Compact dimensions (190mm L x 100mm W x 35mm H) for easy portability.
  • Compatible with Windows 98, Me, NT, 2000, XP, and Vista operating systems.
  • Offers 23 measurement functions.
  • Includes PASS/FAIL Check functionality.
  • Supports waveform average, persistence, intensity, invert, addition, subtraction, multiplication, division, and X-Y plot.
  • Ability to save waveforms as text files, JPG/BMP graphic files, or MS Excel/Word files.
  • Features FFT (Fast Fourier Transform) for spectrum analysis.
  • Allows connection of multiple DSO units to one computer for extended channel capabilities.
  • Supports Labview, VB, VC, Delphi, and C++Builder for second design instances.

3. Package Contents

Upon unpacking your Hantek DSO2090, please ensure all the following items are present:

  • Hantek DSO2090 USB PC Digital Oscilloscope Unit
  • Oscilloscope Probes (2 units)
  • USB Cable
  • Software CD
  • User Manual (this document, or a printed version)
Hantek DSO2090 oscilloscope unit with probes and USB cable
Figure 1: Hantek DSO2090 unit with included probes and USB cable.
Close-up view of oscilloscope probes with accessories
Figure 2: Detailed view of the oscilloscope probes and accessories.

4. System Requirements

To operate the Hantek DSO2090, your computer must meet the following minimum requirements:

  • Operating System: Windows 98, Windows Me, Windows NT, Windows 2000, Windows XP, or Windows Vista.
  • Available USB 2.0 Port.
  • CD-ROM drive for software installation (if not downloading software).

5. Setup Guide

  1. Software Installation: Insert the provided software CD into your computer's CD-ROM drive. Follow the on-screen instructions to install the Hantek oscilloscope software. If a CD is not available, download the latest software from the official Hantek website.
  2. Connect the Oscilloscope: Connect the Hantek DSO2090 unit to an available USB 2.0 port on your computer using the supplied USB cable. The device is powered via USB, so no external power adapter is needed.
  3. Connect Probes: Attach the oscilloscope probes to the CH1 and CH2 input ports on the front of the DSO2090 unit. Ensure a secure connection.
  4. Launch Software: Once the drivers are installed and the device is connected, launch the Hantek oscilloscope application on your computer. The software should automatically detect the connected device.
  5. Probe Calibration (Recommended): Before first use, it is recommended to calibrate the probes. Connect a probe to the calibration output (usually a square wave signal, often labeled CAL or 2Vpp 1KHz) on the oscilloscope unit and follow the software's calibration procedure.
Front view of Hantek DSO2090 showing CH1, CH2, and EXT input ports
Figure 3: Front panel of the DSO2090 with input ports.
Top view of Hantek DSO2090 showing USB port and calibration output
Figure 4: Top view of the DSO2090 showing the USB port and calibration point.

6. Operating Instructions

Operating the Hantek DSO2090 primarily involves interacting with the dedicated software on your PC. Refer to the software's built-in help documentation for detailed instructions on specific functions. Below are general steps for basic operation:

  1. Connect to Circuit: Connect the oscilloscope probes to the circuit or signal you wish to measure. Ensure proper grounding to avoid inaccurate readings or damage.
  2. Adjust Settings: Use the software interface to adjust parameters such as vertical scale (Volts/Div), horizontal scale (Time/Div), trigger level, and coupling (AC/DC/GND).
  3. Auto-Set Function: For quick setup, utilize the 'Autoset' function in the software. This automatically adjusts the vertical and horizontal scales to display a stable waveform.
  4. Waveform Analysis: The software provides various tools for waveform analysis, including cursor measurements (voltage, time), mathematical operations (FFT, addition, subtraction, multiplication, division), and waveform display modes (average, persistence, intensity).
  5. Data Storage: Save important waveforms or measurement data using the software's save functions. You can export data to text, image (JPG/BMP), or Microsoft Office (Excel/Word) formats.
Video 1: Demonstration of oscilloscope waveform display and interaction.

7. Maintenance

  • Cleaning: Use a soft, dry cloth to clean the oscilloscope unit. Do not use abrasive cleaners or solvents.
  • Storage: Store the device in a cool, dry place away from direct sunlight and extreme temperatures.
  • Probe Care: Handle probes carefully. Avoid bending or stressing the cables. Replace damaged probes to ensure accurate measurements.
  • Software Updates: Regularly check the Hantek website for software and driver updates to ensure optimal performance and compatibility.

8. Troubleshooting

  • Device Not Detected:
    • Ensure the USB cable is securely connected to both the oscilloscope and the computer.
    • Verify that the USB port on your computer is functional.
    • Reinstall the device drivers from the provided CD or Hantek's website.
    • Try connecting to a different USB port or computer.
  • No Waveform Display:
    • Check if the probes are correctly connected to the circuit under test.
    • Adjust the vertical (Volts/Div) and horizontal (Time/Div) scales in the software.
    • Use the 'Autoset' function.
    • Ensure the trigger settings are appropriate for the signal being measured.
  • Inaccurate Readings:
    • Perform probe calibration as described in the setup guide.
    • Check for damaged probes or cables.
    • Ensure proper grounding of the oscilloscope and the circuit.

9. Specifications

Parameter Value
Channel2 Channels
Impedance1MΩ 25pF
CouplingAC/DC/GND
Vertical resolution8Bit
Gain range10mV-5V, 9Steps
DC accuracy±3%
Timebase range4ns-1h, 38 Steps
Vertical adjustableYes
Input protectionDiodeclamping
X-YYes
AutosetYes (30Hz to 40MHz)
EXT. inputYes
Trigger ModeAuto, Normal and Single
Trigger Slope+/-
Trigger level adjustableYes
Trigger TypeRising edge, falling edge
Trigger SourceCH1, CH2, EXT
Pre/Post trigger0-100%
Buffer size10K-32KB/Channel
Shot bandwidthDC to 40MHz
Max. Sample rate100MS/s
Sampling selectionYes
Waveform Displayport/line, waveform average, persistence, intensity
NetworkOpen/Close
Vertical modeCH1, CH2, Dual, ADD
Cursor measurementYes
Spectrum Analyzer
Channel2 Channels
MathFFT, addition, subtraction, multiplication, division.
Bandwidth40MHz
CursorFrequency, Voltage
Data Samples10K-32K/Channel
Detailed specifications table for Hantek DSO2090
Figure 5: Original specifications table.

10. User Tips

  • Always ensure proper grounding to protect both the device and the user.
  • For stable readings, especially with high-frequency signals, use the shortest possible ground lead on your probes.
  • Familiarize yourself with the software interface and its various functions to maximize the utility of your oscilloscope.
  • When measuring sensitive circuits, consider using the probe's attenuation settings (e.g., 10X) to reduce loading effects.

11. Warranty and Support

For warranty information, technical support, or service inquiries, please refer to the documentation included with your product or visit the official Hantek website. A detailed user manual in PDF format is available for download, which may contain additional information and advanced usage instructions. You can access the PDF manual via this link: Hantek DSO2090 User Manual (PDF).

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.