1. Introduction

The Winsen ZE15-CO is a general-purpose, miniaturized electrochemical carbon monoxide (CO) gas sensor module. It utilizes advanced electrochemical principles for highly selective and stable CO detection in the air. This module integrates a temperature sensor for compensation and provides both digital (UART) and analog voltage outputs, making it versatile and easy to integrate into various applications.

The ZE15-CO module is designed for reliable performance with low power consumption and a long operational lifespan, making it suitable for a wide range of gas detection needs.

Winsen ZE15-CO Carbon Monoxide Gas Sensor Module
Figure 1: Winsen ZE15-CO Carbon Monoxide Gas Sensor Module. Key features include high sensitivity, UART output, long lifespan, and a detectable range of 0-500 ppm (customizable).

2. Safety Information

  • This module is intended for integration into larger systems. Ensure proper handling to avoid electrostatic discharge (ESD).
  • Do not expose the sensor to corrosive gases or high concentrations of organic solvents, as this may damage the sensing element.
  • Avoid mechanical shock or vibration to the sensor module.
  • Ensure the power supply voltage is within the specified range (5V ~ 12V DC) to prevent damage.
  • This sensor is for detection purposes and should not be used as the sole safety device in critical life-safety applications without redundant systems.

3. Product Overview and Features

The ZE15-CO module is a compact unit designed for accurate carbon monoxide detection. Its core features include:

  • High Sensitivity and Resolution: Capable of detecting CO concentrations with high precision (0.1 ppm resolution).
  • Multiple Output Options: Provides both UART digital output (0 or 3V logic) and analog voltage output for flexible integration.
  • High Stability and Anti-interference: Designed for reliable performance in various environments with strong resistance to interfering gases like alcohol.
  • Low Power Consumption: Efficient operation suitable for battery-powered applications.
  • Long Lifespan: Expected operational life of 3-5 years in air.
  • Temperature Compensation: Built-in temperature sensor ensures accurate readings across its operating temperature range.
ZE15-CO Product Features and Applications
Figure 2: Overview of ZE15-CO product features and application areas, including household and industrial CO alarms, air quality monitoring, and smart home devices.

4. Specifications

ParameterValue
Product ModelZE15-CO
Detected GasCarbon Monoxide (CO)
Interfering GasAlcohol and other gases
Output DataUART output (0 or 3V logic)
Working Voltage5V ~ 12V DC
Preheating Time30 seconds
Response Time≤30 seconds
Recovery Time≤30 seconds
Detection Range0 ~ 500 ppm
Resolution0.1 ppm
Working Temperature-10°C ~ 55°C
Working Humidity15%RH-90%RH (non-condensing)
Storage Temperature-10°C ~ 55°C
Lifespan3-5 years (in air)
Environmental CertificationRoHS Compliant
DIY SuppliesElectrical
ZE15-CO Product Parameters and Dimensions
Figure 3: Detailed product parameters and a diagram illustrating the physical dimensions of the ZE15-CO module for integration.

5. Setup and Installation

5.1 Pinout Description

Refer to the product size diagram (Figure 3) for pin locations. The module typically features standard pin headers for power, ground, and data communication (UART TX/RX, possibly analog out).

  • VCC: Power supply input (5V ~ 12V DC).
  • GND: Ground connection.
  • TX: UART Transmit pin (connect to RX of your microcontroller).
  • RX: UART Receive pin (connect to TX of your microcontroller).
  • AOUT: Analog Voltage Output (if available on your specific module variant).

5.2 Connection Guide

  1. Connect the VCC pin of the ZE15-CO module to a stable 5V-12V DC power source.
  2. Connect the GND pin of the module to the ground of your power supply and microcontroller.
  3. For digital communication, connect the TX pin of the ZE15-CO to the RX pin of your microcontroller, and the RX pin of the ZE15-CO to the TX pin of your microcontroller. Ensure voltage compatibility (e.g., use level shifters if your microcontroller operates at 3.3V and the module's UART is 5V).
  4. If using analog output, connect the AOUT pin to an analog input pin on your microcontroller.
  5. Mount the sensor in a location where CO detection is required, ensuring good air circulation around the sensor element. Avoid placing it in dead air pockets or directly in front of vents.

6. Operating Instructions

6.1 Power On and Preheating

After connecting the module to power, it requires a preheating period of approximately 30 seconds. During this time, the sensor stabilizes, and readings may not be accurate. Wait for the preheating period to complete before taking measurements.

6.2 Reading Data (UART)

The ZE15-CO module communicates via a standard UART serial interface. You will need to configure your microcontroller's serial port to match the module's baud rate (typically 9600 bps, 8 data bits, no parity, 1 stop bit). The module will output CO concentration data in a defined protocol. Refer to the detailed communication protocol document (usually provided by the manufacturer) for parsing the data frames.

6.3 Reading Data (Analog)

If your module provides an analog output, the voltage level will correspond to the CO concentration. You will need to calibrate this output based on the module's datasheet or by performing a two-point calibration (e.g., in fresh air for 0 ppm and in a known CO concentration). The analog output range typically scales from 0V to VCC or a specific range like 0.4V to 2V for 0-500ppm.

6.4 Response and Recovery

The sensor has a response time of ≤30 seconds to detect changes in CO concentration and a recovery time of ≤30 seconds to return to baseline after the CO source is removed.

7. Maintenance

  • Cleaning: Keep the sensor surface clean. Gently wipe any dust or debris with a soft, dry cloth. Do not use liquids or solvents directly on the sensor element.
  • Calibration: Electrochemical sensors may experience drift over long periods. Periodic calibration against a known CO source is recommended for applications requiring high accuracy. Consult Winsen for calibration procedures or services.
  • Storage: When not in use, store the module in a clean, dry environment within the specified storage temperature range (-10°C ~ 55°C).

8. Troubleshooting

  • No Output/Incorrect Readings:
    • Check power supply connections and voltage.
    • Verify UART wiring (TX to RX, RX to TX) and baud rate settings.
    • Ensure the preheating time has elapsed.
    • Check for any physical damage to the sensor.
  • Sensor Not Responding to CO:
    • Confirm the CO source is present and at a detectable concentration.
    • Ensure the sensor is not obstructed and has proper air circulation.
    • The sensor may have reached the end of its lifespan if it's very old.
  • High Readings in Fresh Air:
    • Allow sufficient time for the sensor to stabilize after power-up.
    • Check for interfering gases (e.g., alcohol vapors) in the environment.
    • Consider recalibration if persistent.

9. User Tips

  • For best accuracy, allow the sensor to operate for at least 5 minutes after initial power-up before taking critical readings.
  • When integrating, consider the module's dimensions and pin layout carefully to ensure proper fit and connection.
  • Protect the sensor from direct water splashes or high humidity environments beyond its specified operating range.
  • If using the analog output, ensure your ADC has sufficient resolution for the desired accuracy.

10. Frequently Asked Questions (FAQ)

Q: What is the typical lifespan of the ZE15-CO sensor?

A: The ZE15-CO sensor has an expected lifespan of 3-5 years when operated in normal air conditions.

Q: Can this sensor detect other gases besides Carbon Monoxide?

A: While primarily designed for CO, electrochemical sensors can sometimes show minor cross-sensitivity to other gases. The ZE15-CO is noted to have potential interference from alcohol and similar gases. Always refer to the datasheet for detailed cross-sensitivity information.

Q: How often should I calibrate the sensor?

A: For critical applications, periodic calibration (e.g., every 6-12 months) is recommended to maintain accuracy due to potential sensor drift over time.

11. Warranty and Support

11.1 Warranty

The ZE15-CO Carbon Monoxide Gas Sensor Module typically comes with a one-year warranty from the date of purchase, covering manufacturing defects. Please retain your proof of purchase for warranty claims. The warranty does not cover damage caused by misuse, improper installation, accidents, or unauthorized modifications.

11.2 Technical Support

For detailed technical specifications, communication protocols, test circuits, procedures, or any other technical inquiries, please contact Winsen customer service or your local distributor. They can provide professional selection advice and technical support.

Video 1: Winsen Company Overview. This video showcases Winsen's manufacturing facilities, R&D capabilities, and the diverse applications of their sensor technologies.

For further information, please refer to the official user manual PDF available from the manufacturer.

© 2023 Winsen Electronics Technology Co., Ltd. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.