Introduction
This manual provides essential information for the safe and effective use of your Smart WiFi Gas Leak Detector. Please read it thoroughly before installation and operation, and keep it for future reference. This device is designed to detect natural gas, LPG, biogas, and methane, providing real-time monitoring and alarm notifications through its digital display and a connected mobile application.
Package Contents
Ensure all items are present before proceeding with installation:
- 1 x Smart WiFi Gas Leak Sensor
- 1 x USB Type-C Cable
- 2 x Screws (for mounting)
- 1 x Instruction Manual
Specifications
| Smart Home Platform | Tuya |
| Certification | NONE |
| Origin | Mainland China |
| Model Number | Gas Detector |
| Installation Method | Wall mounted/Ceiling mounted |
| Working Voltage | 5V |
| Power Supply Mode | USB Type-C |
| Alarm Volume | ≥ 90dB |
| Alarm Setting Value (APP adjustment) | 20ppm (default value) |
| Wi-Fi Standard | IEEE 802.11b/n/g 2.4G |
| Radio Frequency | 433.92 MHz |
| Detection Gas | Natural gas, LPG, biogas, CH4 |
| Application | Smart Life |
| Net Weight | 85g |
| Gross Weight | 127g |
| Product Size | 91 * 91 * 28mm (3.6 * 3.6 * 1.1in) |
| Package Size | 105 * 100 * 29mm (4.1 * 3.9 * 1.1in) |
Key Features
- Wifi+Bluetooth-compatible Dual Mode: Offers faster and more stable network connection compared to single Wi-Fi mode.
- Large Screen LCD: Provides real-time display of gas concentration (PPM) and equipment status (POWER, FAULT, ALARM).
- Sound & Light & APP Remote Alarm: Emits a ≥90dB sound alarm and red light flash when gas concentration reaches the alarm value. Sends instant notifications to your mobile application.
- Temperature Change Detection: Can be configured to send an alarm if a set temperature value is exceeded. The app will also notify you if the device goes offline for more than 30 minutes.
- USB Power Supply: Convenient USB Type-C charging eliminates the need for batteries and allows for real-time data updates.
- Multi-Gas Detection: Capable of detecting natural gas, biogas, and methane.
Note: This device does not support smoke detection.
Installation
1. Choosing an Installation Location
The gas leak detector can be wall-mounted or ceiling-mounted. Consider the type of gas you are detecting:
- Natural Gas/Methane/Biogas: These gases are lighter than air and tend to rise. Install the detector on the ceiling or high on a wall, typically within 30cm (12 inches) from the ceiling and at least 1.5m (5 feet) away from gas appliances.
- LPG (Liquefied Petroleum Gas): LPG is heavier than air and sinks. Install the detector low on a wall, typically within 30cm (12 inches) from the floor and at least 1.5m (5 feet) away from gas appliances.
Avoid installing the detector in areas with strong airflow (near windows, doors, or ventilation fans), high humidity (bathrooms), or extreme temperatures.
2. Mounting the Device
- Mark the desired mounting position on the wall or ceiling.
- Drill two holes at the marked positions.
- Insert the provided screws into the holes, leaving a small gap for the detector to hang.
- Align the mounting slots on the back of the detector with the screws and slide the detector into place.
3. Powering the Device
Connect the provided USB Type-C cable to the detector's power port and plug the other end into a 5V USB power adapter (not included). The device will power on automatically.
4. APP Connection and Setup
To utilize the smart features, download the 'Smart Life' or 'Tuya Smart' application from your mobile app store. Follow the in-app instructions to add your device. The Wifi+Bluetooth-compatible dual mode ensures a faster and more stable connection process. Ensure your Wi-Fi network is 2.4GHz (IEEE 802.11b/n/g).



Operation
1. Digital Display Indicators
The large LCD screen provides real-time information:
- GAS: Indicates the current gas concentration in PPM (parts per million).
- POWER: Green light indicates the device is powered on and operating normally.
- FAULT: Yellow light indicates a device malfunction.
- ALARM: Red light indicates an active gas leak alarm.


2. Alarm Conditions
The device will trigger an alarm under the following conditions:
- Gas Concentration: When the detected gas concentration reaches or exceeds the preset alarm value (default 20ppm). The device will emit a ≥90dB audible alarm, flash a red light, and send a notification to the connected mobile application.
- Temperature Change: If a specific temperature threshold is set in the app and exceeded, the device will trigger an alarm.
- Offline Status: If the smart WiFi gas leak detector goes offline for more than 30 minutes, the mobile application will send an alert.

Maintenance
- Regular Cleaning: Gently wipe the exterior of the detector with a soft, dry cloth to remove dust. Do not use abrasive cleaners or solvents.
- Avoid Obstruction: Ensure the ventilation holes on the device are not blocked by dust, debris, or other objects.
- Self-Test: Periodically check the device's functionality by observing the display and indicator lights. The device automatically detects faults, indicated by a yellow 'FAULT' light.
- Power Supply: Ensure a stable 5V USB Type-C power supply.
Troubleshooting
| Problem | Possible Cause | Solution |
| Device not powering on | No power, faulty USB cable/adapter | Check USB Type-C cable connection and power adapter. Ensure 5V power supply. |
| Yellow 'FAULT' light is on | Internal device malfunction | The device has detected an internal fault. Try restarting the device by unplugging and re-plugging the power. If the fault persists, contact customer support. |
| No APP notifications / Device offline | Wi-Fi disconnected, device offline, app not configured correctly | Check your home Wi-Fi network. Ensure the device is within Wi-Fi range. Re-check APP connection steps. The app will remind you if the device is offline for 30 minutes. |
| Inaccurate gas readings | Sensor obstruction, incorrect installation location | Ensure the sensor is not obstructed. Verify the installation location is appropriate for the gas type (lighter gases higher, heavier gases lower). |
| Device does not detect smoke | This device is not designed for smoke detection | This product is specifically for detecting natural gas, LPG, biogas, and methane. It cannot detect smoke. Use a dedicated smoke detector for smoke detection. |
| Cannot connect to Tuya app on Samsung devices | Compatibility issue | Tuya series products may not be suitable for all Samsung devices. Please refer to Tuya's compatibility list or contact Tuya support. |
User Tips
- For optimal performance, ensure the device is always connected to a stable 2.4GHz Wi-Fi network. The dual Wi-Fi and Bluetooth mode enhances connection stability.
- Regularly check the digital display for current gas levels and device status.
- Test the alarm function periodically to ensure it is working correctly.
- Familiarize yourself with the alarm sound and light indicators so you can react quickly in an emergency.
- Keep the Smart Life or Tuya Smart app updated on your phone to receive the latest features and security patches.
Warranty and Support
For detailed warranty information and customer support, please refer to the seller's store page or contact the seller directly. Additional item guides and documents, including a PDF user manual, may be available for download. You can find the PDF manual at: User manual (PDF).