1. About This Manual
1.1. Purpose
This manual describes the assembly, installation, operation, and troubleshooting of this unit. Please read this manual carefully before installations and operations. Keep this manual for future reference.
1.2. Scope
This manual provides safety and installation guidelines as well as information on tools and wiring.
2. Safety Instructions
WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.
- Before using the unit, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
- CAUTION – To reduce risk of injury, charge only deep-cycle lead acid type rechargeable batteries. Other types of batteries may burst, causing personal injury and damage.
- Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
- To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
- CAUTION – Only qualified personnel can install this device with battery.
- NEVER charge a frozen battery.
- For optimum operation of this inverter/charger, please follow required spec to select appropriate cable size. It's very important to correctly operate this inverter/charger.
- Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts and could cause an explosion.
- Please strictly follow installation procedure when you want to disconnect AC or DC terminals. Please refer to the INSTALLATION section of this manual for the details.
- Fuse is provided as over-current protection for the battery supply.
- GROUNDING INSTRUCTIONS - This inverter/charger should be connected to a permanent grounded wiring system. Be sure to comply with local requirements and regulation to install this inverter.
- NEVER cause AC output and DC input short circuited. Do NOT connect to the mains when DC input short circuits.
- Warning!! Only qualified service persons are able to service this device. If errors still persist after following troubleshooting table, please send this inverter/charger back to local dealer or service center for maintenance.
3. Introduction
This is a multi-function inverter/charger, combining functions of inverter, MPPT solar charger and battery charger to offer uninterruptible power support with portable size. Its comprehensive LCD display offers user-configurable and easy-accessible button operation such as battery charging current, AC/solar charger priority, and acceptable input voltage based on different applications.
3.1. Features
- Pure sine wave inverter
- Inverter running without battery
- Built-in MPPT solar controller
- Configurable input voltage range for home appliances and personal computers via LCD setting
- Configurable battery charging current based on applications via LCD setting
- Configurable AC/Solar Charger priority via LCD setting
- Compatible to mains voltage or generator power
- Auto restart while AC is recovering
- Overload/ Over temperature/ short circuit protection
- Smart battery charger design for optimized battery performance
- Cold start function
3.2. Basic System Architecture
The following illustration shows basic application for this inverter/charger. It also includes following devices to have a complete running system:
- Generator or Utility.
- PV modules (option)
Consult with your system integrator for other possible system architectures depending on your requirements.
This inverter can power all kinds of appliances in home or office environment, including motor-type appliances such as tube light, fan, refrigerator and air conditioner.


4. Product Overview


5. Installation
5.1. Unpacking and Inspection
Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. You should have received the following items inside of package:
- The unit x 1
- User manual x 1
- PV connector x 4
- Battery fuse x 1 (Only 11K model)
The product is well-packaged with foam protection to keep the unit safe during shipping.
5.2. Preparation
Before connecting all wirings, please take off the bottom cover by removing four screws.
5.3. Mounting the Unit
Consider the following points before selecting where to install:
- Do not mount the inverter on flammable construction materials.
- Mount on a solid surface.
- Install this inverter at eye level in order to allow the LCD display to be read at all times.
- The ambient temperature should be between 0°C and 55°C to ensure optimal operation.
- The recommended installation position is to be adhered to the wall vertically.
- Be sure to keep other objects and surfaces as shown in the right diagram to guarantee sufficient heat dissipation and to have enough space for removing wires.
SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.

5.4. Battery Connection
CAUTION: For safety operation and regulation compliance, it's requested to install a separate DC over-current protector or disconnect device between battery and inverter. It may not be requested to have a disconnect device in some applications, however, it's still requested to have over-current protection installed. Please refer to typical amperage in below table as required fuse or breaker size.
WARNING! All wiring must be performed by a qualified personnel.
WARNING! It's very important for system safety and efficient operation to use appropriate cable for battery connection. To reduce risk of injury, please use the proper recommended cable.
Recommended Battery Cable & Terminal Size:
| Model | Maximum Amperage | Battery Capacity | Wire Size | Cable mm² | Terminal Size (mm) L x W x D | Torque Value |
|---|---|---|---|---|---|---|
| 8.5KVA | 180A | 400AH | 4AWG*2 | 25 | 37 x 22 x 8.4 | 10~12 Nm |
| 11.0KVA | 220A | 600AH | 2AWG*2 | 38 | 37 x 22 x 8.4 | 10~12 Nm |
Battery Connection Steps:
- Make positive and negative cables based on recommended terminal size.
- Connect all battery packs as units require. It's suggested to use recommended battery capacity.
- Insert battery cable flatly into battery connector of inverter and make sure the bolts are tightened with torque of 10-12Nm. Make sure polarity at both the battery and the inverter/charge is correctly connected and battery cables are tightly screwed to the battery connector.

5.5. AC Input/Output Connection
CAUTION: Before connecting to AC input power source, please install a separate AC breaker between inverter and AC input power source. This will ensure the inverter can be securely disconnected during maintenance and fully protected from over current of AC input. The recommended spec of AC breaker is 63A.
CAUTION: There are two terminal blocks with "IN" and "OUT" markings. Please do NOT mis-connect input and output connectors.
WARNING! All wiring must be performed by qualified personnel.
WARNING! It's very important for system safety and efficient operation to use appropriate cable for AC input connection. To reduce risk of injury, please use the proper recommended cable size as below.
Suggested Cable Requirement for AC Wires:
| Model | Gauge | Torque Value |
|---|---|---|
| All Model | 6 AWG | 1.2~1.4Nm |
AC Input/Output Connection Steps:
- Before making AC input/output connection, be sure to open DC protector or disconnector first.
- Remove insulation sleeve 10mm for six conductors. And shorten phase L and neutral conductor N 3 mm.
- Insert AC input wires according to polarities indicated on terminal block and tighten the terminal screws. Be sure to connect PE protective conductor (yellow-green) first.
- →Ground (yellow-green)
- L→LINE (brown or black)
- N→Neutral (blue)
WARNING: Be sure that AC power source is disconnected before attempting to hardwire it to the unit.
- Then, insert AC output wires according to polarities indicated on terminal block and tighten terminal screws. Be sure to connect PE protective conductor (yellow-green) first.
- →Ground (yellow-green)
- L→LINE (brown or black)
- N→Neutral (blue)
- Make sure the wires are securely connected.
CAUTION: Important Be sure to connect AC wires with correct polarity. If L and N wires are connected reversely, it may cause utility short-circuited when these inverters are worked in dual output operation.
CAUTION: Appliances such as air conditioner are required at least 2~3 minutes to restart because it's required to have enough time to balance refrigerant gas inside of circuits. If a power shortage occurs and recovers in a short time, it will cause damage to your connected appliances. To prevent this kind of damage, please check manufacturer of air conditioner if it's equipped with time-delay function before installation. Otherwise, this inverter/charger will trig overload fault and cut off output to protect your appliance but sometimes it still causes internal damage to the air conditioner.
5.6. PV Connection
CAUTION: Before connecting to PV modules, please install separately a DC circuit breaker between inverter and PV modules.
WARNING! All wiring must be performed by qualified personnel.
WARNING! It's very important for system safety and efficient operation to use appropriate cable for PV module connection. To reduce risk of injury, please use the proper recommended cable size as below.
Suggested Cable Requirement for PV Wires:
| Model | Typical Amperage | Cable Size | Torque |
|---|---|---|---|
| All Model | 18A*2 | 10 AWG | 1.4~1.6 Nm |
PV Module Selection:
When selecting proper PV modules, please be sure to consider below parameters:
- Open circuit Voltage (Voc) of PV modules not exceeds max. PV array open circuit voltage of inverter.
- Open circuit Voltage (Voc) of PV modules should be higher than min. battery voltage.
Solar Charging Mode Specifications:
| INVERTER MODEL | 8.5KVA | 11.0KVA |
|---|---|---|
| Max. PV Array Open Circuit Voltage | 500VDC | |
| PV Array MPPT Voltage Range | 60VDC~500VDC | |
| Max. PV INPUT CURRENT | 18A*2 | |
Take the 450Wp and 550Wp PV module as an example. After considering above two parameters, the recommended module configurations are listed in the table below. The recommended module configurations are fit for PV1 or PV2; for example: PV1 is 8 pcs in serial and PV1 could be 8 pcs in serial too, total quantity of panels is 16pcs.
Solar Panel Configuration Examples:
| Solar Panel Spec. (reference) | SOLAR INPUT | Q'ty of panels | Total input power | Inverter Model |
|---|---|---|---|---|
| 450Wp Vmp: 34.67Vdc Imp: 13.82A Voc: 41.25Vdc Isc: 12.98A | 3 pcs in serial | 3 pcs | 1,350 W | All Model |
| 4 pcs in serial | 4 pcs | 1,800 W | ||
| 5 pcs in serial | 5 pcs | 2,250 W | ||
| 6 pcs in serial | 6 pcs | 2,700 W | ||
| 7 pcs in serial | 7 pcs | 3,150 W | ||
| 8 pcs in serial | 8 pcs | 3,600 W | ||
| 450Wp (continued) | 9 pcs in serial | 9 pcs | 4,050 W | All Model |
| 10 pcs in serial | 10 pcs | 4,500 W | ||
| 11 pcs in serial | 11 pcs | 4,950 W | ||
| 12 pcs in serial | 12 pcs | 5,400 W | ||
| 550Wp Vmp: 42.48Vdc Imp: 12.95A Voc: 50.32Vdc Isc: 13.70A | 3 pcs in serial | 3 pcs | 1,650 W | All Model |
| 4 pcs in serial | 4 pcs | 2,200 W | ||
| 5 pcs in serial | 5 pcs | 2,750 W | ||
| 6 pcs in serial | 6 pcs | 3,300 W | ||
| 7 pcs in serial | 7 pcs | 3,850 W | ||
| 8 pcs in serial | 8 pcs | 4,400 W | ||
| 9 pcs in serial | 9 pcs | 4,950 W |
PV Module Wire Connection Steps:
- Remove insulation sleeve 10 mm for positive and negative conductors.
- Check correct polarity of connection cable from PV modules and PV input connectors. Then, connect positive pole (+) of connection cable to positive pole (+) of PV input connector. Connect negative pole (-) of connection cable to negative pole (-) of PV input connector.
- Make sure the wires are securely connected.

6. Final Assembly
After connecting all wirings, please put the bottom cover back by screwing four screws.
7. Operation
7.1. Power ON/OFF
Once the unit has been properly installed and the batteries are connected well, simply press the On/Off switch (located on the bottom of the case) to turn on the unit.
7.2. Operation and Display Panel
The operation and display panel, shown below, is on the front panel of the inverter. It includes three indicators, four function keys, and an LCD display, indicating the operating status and input/output power information.

RGB Indicator (Default)
| Mode | Color | Status | Messages |
|---|---|---|---|
| Inverter mode | Green | Solid On | Output is powered by battery or PV in battery mode Battery is fully charged or isn't charged. |
| Flashing | Battery is charging with 2s-on and 1s-off | ||
| AC mode | Blue | Solid On | Output is powered by AC or PV in AC mode Battery is fully charged or isn't charged |
| Flashing | Battery is charging with 2s-on and 1s-off | ||
| Standby mode | Cyan | Solid On | Battery is fully charged or isn't charged |
| Flashing | Battery is charging with 2s-on and 1s-off | ||
| Fault mode | Red | Solid On | Fault occurs in the inverter. |
| Bypass mode | Purple | Solid On | Working in AC mode without charging |
| Charging mode | Yellow | Solid On | Battery is fully charged, when switch is off |
| Flashing | Battery is charging, when switch is off |
Function Keys:
| Function Key | Description |
|---|---|
| ESC | To exit setting mode |
| UP | To go to previous selection |
| DOWN | To go to next selection |
| ENTER | To confirm the selection in setting mode or enter setting mode |
7.3. LCD Display
The LCD display information will be switched in turns by pressing keys. All of information could be shown in 1/2/3/4/5 area of LCD.
LCD Display Explanation:
- **Area 1:** Shows PV data, such as PV voltage/current/power.
- **Area 2:** Shows battery data, such as battery voltage/current/power/SOC.
- **Area 3:** Shows AC-output data, such as output voltage/current/power/percentage/frequency.
- **Area 4:** Shows AC-input data, such as input voltage/current/power/percentage/frequency.
- **Area 5:** Shows setting program code/Eco/buzzer/error/warning.
- **Area 6:** Shows power generation/time/date.
LCD Data Polling Display Mode:
- **Simultaneously polling data:** Press "UP" or "DOWN" button to show all data from area-1 to area-4 simultaneously and all dates will be updated with pressing. Press the ESC key to return the initial data.
- **Independent polling data:** Data of area 1-4 could be polling displayed independently as follows:
- Press "Enter" key, circle icon of area 1 will be flashing, press "UP" or "DOWN" to display data of area 1.
- Continue to press "Enter" key, circle icon of area 2 will be flashing, press "UP" or "DOWN" to display data of area 2.
- Continue to press "Enter" key, circle icon of area 3 will be flashing, press "UP" or "DOWN" to display data of area 3.
- Continue to press "Enter" key, circle icon of area 4 will be flashing, press "UP" or "DOWN" to display data of area 4.
- Continue to press "Enter" key, circle icon of area 1 will be flashing, it would come back to area 1.
LCD Setting Display:
After pressing and holding "Enter" key for 3 seconds, the unit will enter setting mode. Press "UP" or "DOWN" button to select setting programs. And then, press "ENTER" button to confirm the selection or ESC button to exit. When the unit enters setting mode the LCD display shows:
- **Area 5:** Setting program code.
- **Area 6:** Setting program meaning.
- **Area 1:** Setting minimum value, if the setting program has minimum value.
- **Area 4:** Setting maximum value, if the setting program has maximum value.
- **Area 2:** Setting program item.
- **Area 3:** Setting current value which could be set.
Other Display:
Please press and hold the key "Down" for a long time on the main menu page, you could see the following information in area 6:
- Software Version;
- Model code Version;
- CPU type;
- Hardware Version;
7.4. LCD Setting Programs (F0-F4)
The inverter offers extensive configuration options via the LCD display. Here's an overview of the setting groups:
F0: Setting General Parameters
| Program | Description | Selectable Option |
|---|---|---|
| 01 | AC input voltage range | Appliances (default): 90-280VAC UPS: 170-280VAC Generator: 170-280VAC (Note: Generators may cause unstable output) |
| 02 | Power saving mode enable/disable | Disabled: Inverter output not affected by low/high load. Enabled: Inverter output off when connected load is low. |
| 03 | Overload bypass | Bypass disable (default): Unit transfers to line mode if overload occurs in battery mode. Bypass enable: Unit transfers to line mode if overload occurs in battery mode. |
| 04 | Auto restart when overload occurs | Restart disable Restart enable (default) |
| 05 | Auto restart when over temperature occurs | Restart disable Restart enable (default) |
| 06 | Auto bypass | Manual (default) Auto: Automatically bypasses if mains power is normal. |
| 07 | Auto return to default display screen | Return to default display screen (default): Returns after 1 minute of inactivity. Stay at latest screen: Display remains on last screen. |
| 08 | Backlight control | Backlight on Backlight off (default) |
| 09 | Buzzer mode | Mode1 (Buzzer mute) Mode2 (Buzzer sounds on input source change/warning/fault) Mode3 (Buzzer sounds on specific warning/fault) Mode4 (default) (Buzzer sounds on fault) |
| 10 | Modbus ID Setting | Range: 001 (default)~247 |
| 16 | Dry contact mode | Model1 (default): Deliver signal to external device when battery voltage reaches warning level. Model2: Allow neutral and grounding of AC output to be connected together (only when inverter works with external grounding box in battery mode). |
F1: Setting AC Output Parameters
| Program | Description | Selectable Option |
|---|---|---|
| 01 | Output source priority | SUB priority (default): Solar->Utility->Battery. Solar energy charges first, then powers loads. SBU priority: Solar->Battery->Utility. Solar energy powers loads first, then charges battery. SUF priority: Solar->Utility->Battery. Solar energy powers loads first, then charges battery, then feeds to grid. |
| 02 | AC output mode | Single: This inverter is used in single phase application. |
| 03 | Output voltage | 230V (default). Available settings: 220V, 230V, 240V. |
| 04 | Output frequency | 50Hz (default). Available settings: 50Hz and 60Hz. |
| 06 | Slave output source priority | OFF (default): Turn off slave output source priority. SUB, SBU, SUF: Same function as program 01 of F1. |
F2: Setting Battery Parameters
| Program | Description | Selectable Option |
|---|---|---|
| 01 | Battery type | AGM (default) Flooded User-Defined (allows setting charge voltage and low DC cut-off voltage) PYLON US2000 Protocol (3.5 Version) Standard communication Protocol 2 LIB (Lithium battery default values) |
| 16 | Bulk charging time (C.V stage) | Automatically (default): Inverter judges charging time automatically. 5 min to 900 min (increment of 5 min). |
| 17 | Battery equalization | Battery equalization enable/disable (default). |
| 18 | Battery equalization voltage | Default 58.4V. Range: floating voltage (program 04 of F2) ~ 62V. |
| 19 | Battery equalized time | 60min (default). Range: 0min to 900min (increment of 5min). |
| 20 | Battery equalized timeout | 120min (default). Range: 0min to 900min (increment of 5min). |
| 21 | Equalization interval | 30 days (default). Range: 1 to 90 days (increment of 1 day). |
| 22 | Equalization activated immediately | Enable/Disable (default). |
| 23 | Manual activate the lithium battery setting | Active/Disable (default). |
| 24 | Automatic activation for lithium battery | Auto/Disable (default). |
| 25 | Max battery discharge current setting | OFF (default). Range: 50 to 500. |
| 26 | Lithium battery activation time | 6s (default). Range: 6s~300s. |
F3: Setting Time Parameters
| Program | Description | Selectable Option |
|---|---|---|
| 01 | Date setting | Set the machine date (year, month, day) |
| 02 | Time setting | Set the machine time (hours, minutes) |
F4: Setting Systems Parameters
| Program | Description | Selectable Option |
|---|---|---|
| 01 | Reset all stored data of PV generated power and output load energy | Reserve data (default) Reset generated energy data |
| 02 | RGB mode - Checking RGB Indicator table | Mode 1 (Default): RGB LED working normally. Mode 2: RGB LED working with only unit in fault mode. Mode 3: RGB LED always OFF. Mode 4: RGB LED shows as model 1 and whether battery is fully charged or not, RGB LED won't be flashing. Mode 5: RGB LED shows as model 1 and whether battery is fully charged or not, RGB LED will be flashing. |
| 03 | RGB brightness adjustment | Adjust brightness of RGB within 30% to 100%. |
| 04 | RGB Light Color selection in inverter Mode | Red, Green, Blue, Cyan, Purple, Yellow, White, Pale cyan, Pale yellow, Pale blue, Pink. |
8. Battery Equalization
Equalization function is added into the charge controller. It reverses the buildup of negative chemical effects like stratification, a condition where acid concentration is greater at the bottom of the battery than at the top. Equalization also helps to remove sulfate crystals that might have built up on the plates. If left unchecked, this condition, called sulfation, will reduce the overall capacity of the battery. Therefore, it's recommended to equalize battery periodically.
8.1. How to Apply Equalization Function
You must enable battery equalization function in monitoring LCD setting program 17 of F2 first. Then, you may apply this function in device by either one of following methods:
- Setting equalization interval in program 21 of F2.
- Active equalization immediately in program 22 of F2.
8.2. When to Equalize
In float stage, when the setting equalization interval (battery equalization cycle) is arrived, or equalization is active immediately, the controller will start to enter Equalize stage.

8.3. Equalize Charging Time and Timeout
In Equalize stage, the controller will supply power to charge battery as much as possible until battery voltage raises to battery equalization voltage. Then, constant-voltage regulation is applied to maintain battery voltage at the battery equalization voltage. The battery will remain in the Equalize stage until setting battery equalized time is arrived.
However, in Equalize stage, when battery equalized time is expired and battery voltage doesn't rise to battery equalization voltage point, the charge controller will extend the battery equalized time until battery voltage achieves battery equalization voltage. If battery voltage is still lower than battery equalization voltage when battery equalized timeout setting is over, the charge controller will stop equalization and return to float stage.
9. Setting for Lithium Battery
9.1. Lithium Battery Connection
If choosing lithium battery for the inverter, you are allowed to use the lithium battery only which we have configured. There are two connectors on the lithium battery: RS485 port of BMS and power cable.
Please follow below steps to implement lithium battery connection:
- Assemble battery terminal based on recommended battery cable and terminal size (same as Lead acid, see section Lead-acid Battery connection for details).
- Connect the end of RS485 port of battery to BMS(RS485) communication port of inverter.
9.2. Lithium Battery Communication and Setting
If choosing a lithium battery, make sure to connect the BMS communication cable between the battery and the inverter. This communication cable delivers information and signals between the lithium battery and the inverter. This information is listed below:
- Re-configure charging voltage, charging current, and battery discharge cut-off voltage according to the lithium battery parameters.
- Have the inverter start or stop charging according to the status of the lithium battery.
Connect the end of RS485 of battery to RS485 communication port of inverter
Make sure the lithium battery RS485 port connects to the inverter is Pin to Pin, the communication cable is inside of package and the inverter RS485 port pin assignment shown as below:
| Pin number | RS485 Port |
|---|---|
| PIN1 | RS485-B |
| PIN2 | RS485-A |
| PIN7 | RS485-A |
| PIN8 | RS485-B |
9.3. Setting for PYLON US2000 Lithium Battery
PYLONTECH US2000 Lithium Battery Setting:
Dip Switch: There are 4 Dip Switches that set different baud rate and battery group address. If switch position is turned to the "OFF" position, it means "0". If switch position is turned to the "ON" position, it means "1".
- Dip 1 is "ON" to represent the baud rate 9600.
- Dip 2, 3 and 4 are reserved for battery group address.
- Dip switch 2, 3 and 4 on master battery (first battery) are to set up or change the group address.
NOTE: "1" is upper position and "0" is bottom position.
Process of Install:
- Use the RS485 cable to connect inverter and Lithium battery.
- Switch on Lithium battery.
- Press more than three seconds to start Lithium battery, power output ready.
- Turn on the inverter.
- Be sure to select battery type as "Li2" in LCD program 5. If communication between the inverter and battery is successful, the battery icon on the LCD display will light up.
9.4. Setting for Lithium Battery Without Communication
This suggestion is used for lithium battery application and to avoid lithium battery BMS protection without communication. Please finish the setting as follows:
A. Recommended method 1: Set battery type as "LIB" in program 01 of F2;
B. Recommended method 2: Setting as follows:
- Before starting setting, you must get the battery BMS specification:
- Max charging voltage
- Max charging current
- Discharging protection voltage
- Set battery type as "LIB" in program 01 of F2;
- Set C.V voltage as Max charging voltage of BMS-0.5V in program 03 of F2;
- Set floating charging voltage as C.V voltage in program 03 of F2;
- Set Low DC cut-off voltage ≥ discharging protection voltage of BMS+3V;
- Set Max charging current in program 09 of F2 which must be less than the Max charging current of BMS.
- Setting voltage point back to utility source when selecting "SBU priority" in program 05 of F2.
The setting value must be ≥Low DC cut-off voltage+2V, or else the inverter will have a warning as battery voltage low.
Remark:
- You'd better to finish setting without turn on the inverter (just let the LCD show, no output);
- When you finish setting, please restart the inverter.
10. Specifications
10.1. Table 1 Line Mode Specifications
| INVERTER MODEL | 8.5KVA | 11.0KVA |
|---|---|---|
| Input Voltage Waveform | Sinusoidal (utility or generator) | |
| Nominal Input Voltage | 230Vac | |
| Low Loss Voltage | 170Vac±7V (UPS) 90Vac±7V (Appliances) | 170Vac±7V (UPS) 90Vac±7V (Appliances) |
| Low Loss Return Voltage | 180Vac±7V (UPS) 100Vac±7V (Appliances) | 180Vac±7V (UPS) 100Vac±7V (Appliances) |
| High Loss Voltage | 280Vac±7V | |
| High Loss Return Voltage | 270Vac±7V | |
| Max AC Input Voltage | 300Vac | |
| Nominal Input Frequency | 50Hz / 60Hz (Auto detection) | |
| Low Loss Frequency | 40±1Hz | |
| Low Loss Return Frequency | 42±1Hz | |
| High Loss Frequency | 65±1Hz | |
| High Loss Return Frequency | 63±1Hz | |
| Output Short Circuit Protection | Battery mode: Electronic Circuits | |
| Efficiency (Line Mode) | >95% (Rated R load, battery full charged) | |
| Transfer Time | 10ms typical (UPS); 20ms typical (Appliances) | |
Output Power Derating:
When AC input voltage drops to 95V or 170V depending on models, the output power will be derated.
When battery voltage drops to 50.5V (8.5K) / 55.0V (11K), the output power will be derated.
10.2. Table 2 Inverter Mode Specifications
| INVERTER MODEL | 8.5KVA | 11.0KVA |
|---|---|---|
| Rated Output Power | 8.5KVA/8.5KW | 11.0KVA/11.0KW |
| Dual output function | Yes | |
| Max. main output power | 8.5KVA/8.5KW | 11.0KVA/11.0KW |
| Max. second output power | 5.0KVA/5.0KW | 5.5KVA/5.5KW |
| Output Voltage Waveform | Pure Sine Wave | |
| Output Voltage Regulation | 230Vac±5% | |
| Output Frequency | 60Hz or 50Hz | |
| Peak Efficiency | 94% | |
| Overload Protection | 5.5s@≥140% load; 10.5s@100%~140% load | |
| Surge Capacity | 2* rated power for 5 seconds | |
| Nominal DC Input Voltage | 48Vdc | |
| Cold Start Voltage | 46.0Vdc | |
| Low DC Warning Voltage (Just for AGM and Flooded) | @ load < 20%: 44.0Vdc @ 20% ≤ load < 50%: 42.8Vdc @ load ≥ 50%: 40.4Vdc | |
| Low DC Warning Return Voltage (Just for AGM and Flooded) | @ load < 20%: 46.0Vdc @ 20% ≤ load < 50%: 44.8Vdc @ load ≥ 50%: 42.4Vdc | |
| Low DC Cut-off Voltage (Just for AGM and Flooded) | @ load < 20%: 42.0Vdc @ 20% ≤ load < 50%: 40.8Vdc @ load ≥ 50%: 38.4Vdc | |
10.3. Table 3 Charge Mode Specifications (Utility Charging Mode)
| INVERTER MODEL | 8.5KVA | 11.0KVA |
|---|---|---|
| Charging Current (Max) (AC+PV) | 140Amp | 160Amp |
| AC Charging Current (Max) | 120Amp (@ VI/P=230Vac) | |
| Bulk Charging Voltage (Flooded Battery) | 58.4Vdc | |
| Bulk Charging Voltage (AGM / Gel Battery) | 56.4Vdc | |
| Floating Charging Voltage | 54Vdc | |
| Overcharge Protection | 63Vdc | |
| Charging Algorithm | 3-Step | |
10.4. Table 3 Charge Mode Specifications (Solar Input)
| INVERTER MODEL | 8.5KVA | 11.0KVA |
|---|---|---|
| Rated Power | 5000W*2 | 5500W*2 |
| Max. PV Array Open Circuit Voltage | 500Vdc | |
| PV Array MPPT Voltage Range | 60Vdc~500Vdc | |
| Max. MPPT Charge Current | 140A | 160A |
| Max. Input Current | 18A*2 | |
10.5. Table 4 General Specifications
| INVERTER MODEL | 8.5KVA | 11.0KVA |
|---|---|---|
| Safety Certification | CE | |
| Operating Temperature Range | -10°C to 55°C | |
| Storage temperature | -15°C~60°C | |
| Humidity | 5% to 95% Relative Humidity (Non-condensing) | |
| Dimension (D*W*H), mm | 540x403x122 | |
| Net Weight, kg | 14.4 | 14.8 |
11. Warning Indicator
There are seven groups about warning code, a warning code consists of group code and number, number is first and group code is last, such as OC.
- A: Inverter group fault code
- B: Battery group fault code
- C: PV group fault code
- D: Output group fault code
- E: Parallel group fault code
- F: Other group fault code
- G: Grid group fault code
Warning Code Table:
| Warning Code | Warning Event | Audible Alarm | Icon flashing |
|---|---|---|---|
| 0B | Battery low | Beep once every second | 0B |
| 1B | Battery is not connected | None | 1B |
| 2B | Battery equalization | None | 2B |
| 3B | Battery low and it isn't up to the setting value of program 06 of F2 group | Beep twice every 3 seconds | 3B |
| 4B | Lithium battery communication is abnormal | Beep once every 0.5 second | 4B |
| 5B | Battery discharge overcurrent | None | 5B |
| 1C | PV energy is too weak | Beep twice every 3 seconds | 1C |
| 0D | Overload | Beep once every 0.5 second | 0D |
| 1D | Output power derating | Beep twice every 3 seconds | 1D |
| 3D | The load exceeds the set value of program 12 of F1 | None | 3D |
| 0F | Temperature is too High | Beep three times every second | 0F |
12. Troubleshooting
12.1. Fault Reference Code
There are seven groups about fault code, a fault code consists of group code and number, group code is first and number is last, such as C0.
- A: Inverter group fault code
- B: Battery group fault code
- C: PV group fault code
- D: Output group fault code
- E: Parallel group fault code
- F: Other group fault code
- G: Grid group fault code
Fault Code Table:
| Fault Code | Fault Event | Icon on |
|---|---|---|
| A0 | Output short circuited. | A0 |
| A1 | Output voltage is too high. | A1 |
| A2 | Over current or surge | A2 |
| A3 | Over DC voltage in AC output | A3 |
| A4 | Inverter current offset is too high | A4 |
| A5 | Output voltage is too low | A5 |
| A6 | Inverter negative power | A6 |
| B0 | Battery voltage is too high | B0 |
| B1 | DCDC over current | B1 |
| B2 | DC/DC current offset is too high | B2 |
| C0 | PV over current | C0 |
| C1 | PV over voltage | C1 |
| C2 | PV1 current offset is too high | C2 |
| C3 | PV2 current offset is too high | C3 |
| D0 | Overload time out | D0 |
| D1 | Op current offset is too high | D1 |
| D2 | Op2 current offset is too high | D2 |
| F0 | Over temperature of inverter module | F0 |
| F1 | Over temperature of PV module | F1 |
| F2 | Over temperature of DCDC module | F2 |
| F3 | Bus voltage is too high | F3 |
| F4 | Bus soft start failed | F4 |
| F5 | Bus voltage is too low | F5 |
| F6 | Hardware incompatibility | F6 |
| F7 | Screen communication abnormality | F7 |
12.2. Troubleshooting Table
| Problem | LCD/LED/Buzzer | Explanation / Possible cause | What to do |
|---|---|---|---|
| Unit shuts down automatically during startup process. | LCD/LEDs and buzzer will be active for 3 seconds and then complete off. | The battery voltage is too low | 1. Re-charge battery. 2. Replace battery. |
| No response after power on. | No indication. | 1. The battery voltage is far too low. 2. Battery polarity is connected reversed. | 1. Check if batteries and the wiring are connected well. 2. Re-charge battery. 3. Replace battery. |
| Mains exist but the unit works in battery mode. | Input voltage is displayed as 0 on the LCD and green LED is flashing. | Input protector is tripped | Check if AC breaker is tripped and AC wiring is connected well. |
| Green LED is flashing. | Insufficient quality of AC power. (Shore or Generator) | 1. Check if AC wires are too thin and/or too long. 2. Check if generator (if applied) is working well or if input voltage range setting is correct. (UPS / Appliance) Change output source priority to Utility first. | |
| When the unit is turned on, internal relay is switched on and off repeatedly. | Green LED is flashing. | Set "SBU" or "SUB" as the priority of output source. | Change output source priority to Utility first. |
| LCD display and LEDs are flashing | Battery is disconnected. | Check if battery wires are connected well. | |
| Buzzer beeps continuously and red LED is on. | Fault code D0 | Overload error. The inverter is overload 100% and time is up. | Reduce the connected load by switching off some equipment. |
| Fault code A2 | Output short circuited. | Check if wiring is connected well and remove abnormal load. | |
| Fault code F2 | Internal temperature of inverter component is over 100°C. | Check whether the air flow of the unit is blocked or whether the ambient temperature is too high. | |
| Fault code B0 | Battery is over-charged. | Return to repair center. | |
| Fault code B0 | The battery voltage is too high. | Check if spec and quantity of batteries are meet requirements. | |
| Other issues. | Fault code A1/A5 | Output abnormal (Inverter voltage below than 190Vac or is higher than 260Vac) | 1. Reduce the connected load. 2. Return to repair center. |
| Fault code F3/F4 | Internal components failed. | Return to repair center. | |
| Fault code A2, F5, A3 | Over current or surge. Bus voltage is too low. Output voltage is unbalanced. | Restart the unit, if the error happens again, please return to repair center. | |
| Another fault code | If the wires are connected well, please return to repair center. |
13. User Tips
- For optimal performance, ensure all wiring connections are secure and follow the recommended cable sizes to prevent energy loss and ensure safety.
- Regularly monitor the LCD display for system data and any warning indicators to catch potential issues early.
- When setting up for lithium batteries, carefully follow the communication and dip switch settings to ensure proper integration and battery management.
- If using a generator as an AC input source, be aware that its unstable output might affect the inverter's stability. Consider adjusting AC input voltage range settings accordingly.
- For appliances with motors, like air conditioners, allow sufficient restart time (2-3 minutes) after power interruptions to prevent damage.
14. Warranty and Support
For warranty information, technical support, or service inquiries, please contact your local dealer or authorized service center. Only qualified service personnel should attempt repairs.