1. Introduction
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Aninerel ANL-4.2KW-LV-W 4.2KW 24V 110-120V Hybrid Solar Inverter. This inverter is designed for household use, featuring a pure sine wave output and a built-in 120A MPPT charge controller. It includes a Wi-Fi module for mobile phone connectivity and data monitoring.
Please read this manual thoroughly before installation and operation. Keep it for future reference.
A detailed user manual in PDF format is available for download: User Manual (PDF)
2. Product Overview
2.1 Key Features
- PV Input 500Vdc Max
- Built-in MPPT 120A
- Capable to work without battery
- WIFI remote monitoring optional
- Dual output for smart load management
- Detachable dust cover for harsh environment
- Compatible work with LiFePo4 battery via RS485
- Lithium battery activation function by PV or Utility
- Support multiple output priority: UTL, SOL, SBU, SUB
- EQ function to optimize battery performance and extend lifecycle
Image: Visual representation of the inverter's key features, including MPPT, WiFi, pure sine wave, LCD, PV input range, no battery mode, BMS compatibility, and harsh environment suitability.
2.2 Component Identification
The following diagram illustrates the main components and ports of the inverter:
Image: Front and rear views of the Aninerel inverter. The front panel shows an LCD display, status indicator, charging indicator, fault indicator, and function buttons. The rear panel shows a dry contact port, power on/off switch, RS485 communication port, RS232 communication port, grounding terminal, AC input, AC output, PV input, and battery input terminals.
- LCD display
- Status indicator
- Charging indicator
- Fault indicator
- Function buttons
- Grounding
- RS232 communication port
- RS485 communication port
- AC input
- AC output
- PV input
- Battery input
- Power on/off switch
- Dry contact port
2.3 Application Diagram
Image: Diagram illustrating the typical application of the hybrid solar inverter. It shows connections from solar panels, utility grid, and a generator as input sources. The inverter connects to a battery bank and provides power to household appliances such as TVs/computers, air conditioners, refrigerators, and washing machines.
2.4 Remote Monitoring
The inverter supports monitoring and control via a smart app using its optional WiFi remote monitoring module. This allows you to check the status of your device remotely.
Image: The Aninerel inverter shown next to a smartphone displaying a mobile application interface, indicating the capability for remote monitoring and control via WiFi.
3. Installation
3.1 Unpacking and Inspection
Before installation, carefully inspect the unit for any damage. Ensure all items listed below are present in the package:
- The inverter unit (x1)
- User manual (x1)
- AC terminals (2 red, 2 black)
- PV terminals (1 red, 1 black)
- Ground terminal (1 black)
3.2 Preparation
Before connecting any wiring, remove the bottom cover of the inverter by unscrewing the three screws as shown in the product diagrams.
3.3 Mounting the Unit
Consider the following when selecting a mounting location:
- Do not mount the inverter on flammable construction materials.
- Mount on a solid surface.
- Install the inverter at eye level for easy reading of the LCD display.
- The ambient temperature should be between 0°C and 55°C for optimal operation.
- The recommended installation position is vertically on a wall.
- Ensure sufficient clearance (at least 20cm on sides, 50cm above and below) for heat dissipation and wire access.
WARNING: Suitable for mounting on concrete or other non-combustible surfaces only.
Install the unit by screwing two M4 or M5 screws into the wall, aligning with the mounting holes on the inverter.
3.4 Battery Connection
CAUTION: For safety and compliance, install a separate DC over-current protector or disconnect device between the battery and inverter. Refer to the table below for typical amperage and fuse/breaker size.
WARNING: All wiring must be performed by qualified personnel. Use appropriate cables and terminals to reduce injury risk.
Image: Wiring diagram for connecting batteries to the inverter. It shows two 12V batteries connected in series to form a 24V battery bank, which then connects to the inverter's battery input terminals.
WARNING: Shock Hazard. Installation must be performed with care due to high battery voltage in series.
CAUTION: Do not place anything between the flat part of the inverter terminal to prevent overheating. Do not apply anti-oxidant substance on terminals before connecting. Before final DC connection, ensure positive (+) is connected to positive (+) and negative (-) to negative (-).
Recommended Battery Cable & Terminal Size:
| Model | Maximum Amperage | Battery Capacity | Wire Size | Cable mm² | Terminal L (mm) | Terminal W (mm) | Terminal D (mm) | Torque Value |
|---|---|---|---|---|---|---|---|---|
| 4.2KVA | 175A | 200AH | 1AWG | 50 | 37 | 15.3 | 6.4 | 4~6 Nm |
Battery Connection Steps:
- Prepare battery positive and negative cables according to recommended specifications.
- Connect all battery packs as required. It is suggested to use recommended battery capacity.
- Insert battery cables flatly into the inverter's battery connector. Ensure bolts are tightened with a torque of 4~6 Nm. Verify correct polarity at both the battery and inverter/charger.
3.5 AC Input/Output Connection
CAUTION: Before connecting to AC input power, install a separate AC breaker between the inverter and the AC input power source. This ensures secure disconnection during maintenance and over-current protection. Recommended AC breaker spec is 50A. There are 'IN' and 'OUT' terminal blocks; do NOT mis-connect them.
WARNING: All wiring must be performed by qualified personnel. Use appropriate cables for AC input connection to reduce injury risk.
Suggested Cable Requirement for AC Wires:
| Model | Gauge | Torque Value |
|---|---|---|
| 4.2KVA | 8AWG | 1.4~1.6Nm |
AC Input/Output Connection Steps:
- Before making AC input/output connections, open the DC protector or disconnector.
- Remove 10mm of insulation sleeve for six conductors. Shorten phase L and neutral conductor N by 3mm.
- Insert AC input wires according to polarities indicated on the terminal block and tighten screws. Connect the PE protective conductor first. (Ground: yellow-green, L-Line: brown or black, N-Neutral: blue)
WARNING: Ensure AC power source is disconnected before hardwiring.
Then, insert AC output wires according to polarities and tighten screws. Connect the PE protective conductor first. (Ground: yellow-green, L-Line: brown or black, N-Neutral: blue)- Ensure all wires are securely connected.
CAUTION: Important - Connect AC wires with correct polarity. Reversed L and N wires can cause utility short-circuit in parallel operation. Appliances like air conditioners require 2-3 minutes to restart. A power shortage and quick recovery can damage connected appliances. Check if your air conditioner has a time-delay function; otherwise, the inverter may trigger overload fault to protect it, but internal damage to the appliance can still occur.
3.6 PV Connection
CAUTION: Before connecting PV modules, install a separate DC circuit breaker between the inverter and PV modules.
WARNING: All wiring must be performed by qualified personnel. Use appropriate cables for PV module connection to reduce injury risk.
Image: Diagram showing the connection of solar panels to the inverter. It illustrates how PV modules are connected to the inverter's PV input, which then integrates with the household electrical system.
PV Module Selection Parameters:
- Open circuit Voltage (Voc) of PV modules must not exceed the max. PV array open circuit voltage of the inverter.
- Open circuit Voltage (Voc) of PV modules should be higher than the min. battery voltage.
Solar Charging Mode Specifications:
| INVERTER MODEL | 4.2KVA |
|---|---|
| Max. PV Array Open Circuit Voltage | 500VDC |
| PV Array MPPT Voltage Range | 60VDC~500VDC |
| Max. PV INPUT CURRENT | 27A |
PV Module Wire Connection Steps:
- Remove 6mm of insulation sleeve for positive and negative conductors.
- Check correct polarity of connection cable from PV modules and PV input connectors. Connect positive pole (+) of connection cable to positive pole (+) of PV input connector. Connect negative pole (-) of connection cable to negative pole (-) of PV input connector.
- Ensure wires are securely connected.
3.7 Final Assembly
After connecting all wirings, reattach the bottom cover by screwing in the two screws.
4. Operation
4.1 Power ON/OFF
Once the unit is properly installed and batteries are connected, press the On/Off switch (located on the bottom of the case) to turn on the unit.
4.2 Operation and Display Panel
The front panel of the inverter features an LCD display, three indicators, and four function keys to show operating status and power information.
LED Indicator Messages:
| Indicator | Color | State | Message |
|---|---|---|---|
| AC/INV | Green | Solid On | Output is powered by utility in Line mode. |
| AC/INV | Green | Flashing | Output is powered by battery or PV in battery mode. |
| CHG | Green | Solid On | Battery is fully charged. |
| CHG | Green | Flashing | Battery is charging. |
| FAULT | Red | Solid On | Fault occurs in the inverter. |
| FAULT | Red | Flashing | Warning condition occurs in the inverter. |
Function Keys:
| Function Key | Description |
|---|---|
| ESC | To exit setting mode |
| UP | To go to previous selection |
| DOWN | To go to next selection |
| ENTER | To confirm the selection in setting mode or enter setting mode |
4.3 LCD Setting
Press and hold the ENTER button for 3 seconds to enter setting mode. Use "UP" or "DOWN" to select programs, then "ENTER" to confirm or "ESC" to exit.
Key Settings:
- Program 01 (Output source priority): Configure load power source priority (Utility first, Solar first, SBU priority, SUB priority).
- Program 02 (Maximum charging current): Configure total charging current for solar and utility chargers (Max. charging current = utility charging current + solar charging current). Default is 60A.
- Program 03 (AC input voltage range): Set acceptable AC input voltage range (Appliances, UPS, Generator).
- Program 05 (Battery type): Select battery type (AGM, Flooded, User-Defined, Lithium battery without communication).
- Program 06 (Auto restart when overload occurs): Enable or disable auto restart.
- Program 07 (Auto restart when over temperature occurs): Enable or disable auto restart.
- Program 08 (Output voltage): Set output voltage (110V, 115V, 120V).
- Program 09 (Output frequency): Set output frequency (50Hz, 60Hz).
- Program 10 (Auto bypass): Set to manual or auto.
- Program 11 (Maximum utility charging current): Default is 30A.
- Program 12 (Setting voltage point back to utility source): For SBU priority or Solar first.
- Program 13 (Setting voltage point back to battery mode): For SBU priority or Solar first.
- Program 16 (Charger source priority): Configure charger source priority (Solar first, Solar and Utility, Only Solar).
- Program 18 (Buzzer mode): Set buzzer behavior (Mode1, Mode2, Mode3, Mode4).
- Program 19 (Auto return to default display screen): Enable or disable.
- Program 20 (Backlight control): Turn backlight on or off.
- Program 23 (Overload bypass): Enable or disable.
- Program 25 (Modbus ID Setting): Set Modbus ID (001-247).
- Program 26 (Bulk charging voltage (C.V voltage)): Set if User-Defined battery type is selected.
- Program 27 (Floating charging voltage): Set if User-Defined battery type is selected.
- Program 29 (Low DC cut-off voltage): Set if User-Defined battery type is selected.
- Program 32 (Bulk charging time (C.V stage)): Set charging time (5-900 min).
- Program 33 (Battery equalization): Enable or disable.
- Program 34 (Battery equalization voltage): Set voltage (floating voltage ~ 31V).
- Program 35 (Battery equalized time): Set time (0-900 min).
- Program 36 (Battery equalized timeout): Set timeout (0-900 min).
- Program 37 (Equalization interval): Set interval (1-90 days).
- Program 38 (Allow neutral and grounding of AC output is connected together): Enable or disable.
- Program 39 (Equalization activated immediately): Enable or disable.
- Program 41 (Automatic activation for lithium battery): Enable or disable.
- Program 42 (Manual activation for lithium battery): Enable or disable.
- Program 43 (Setting SOC point back to utility source): For SBU priority or Solar first.
- Program 44 (Setting SOC point back to battery mode): For SBU priority or Solar first.
- Program 45 (Low DC cut-off SOC): Set SOC percentage.
- Program 46 (Maximum discharge current protection): Enable or disable.
- Program 48 (Lithium battery activation time): Set time (6s-300s).
4.4 Dry Contact Signal
A dry contact (3A/250VAC) on the rear panel can signal an external device when battery voltage reaches a warning level.
Dry Contact Port Behavior:
| Unit Status | Condition | NC & C | NO & C |
|---|---|---|---|
| Power Off | Unit is off and no output is powered. | Close | Open |
| Power On | Output is powered from Utility. | Close | Open |
| Power On | Output is powered from Battery or Solar (Program 01 set as Utility) AND Battery voltage < Low DC warning voltage. | Open | Close |
| Power On | Output is powered from Battery or Solar (Program 01 set as Utility) AND Battery voltage > Setting value in Program 13 or battery charging reaches floating stage. | Close | Open |
| Power On | Output is powered from Battery or Solar (Program 01 set as SBU or SUB or Solar first) AND Battery voltage < Setting value in Program 12. | Open | Close |
| Power On | Output is powered from Battery or Solar (Program 01 set as SBU or SUB or Solar first) AND Battery voltage > Setting value in Program 13 or battery charging reaches floating stage. | Close | Open |
5. Battery Equalization
The equalization function in the charge controller helps reverse negative chemical effects like stratification and removes sulfate crystals that reduce battery capacity. Periodic equalization is recommended.
5.1 How to Apply Equalization Function
Enable battery equalization in LCD setting program 33. Then, apply it by:
- Setting the equalization interval in program 37.
- Activating equalization immediately in program 39.
5.2 When to Equalize
In the float stage, when the set equalization interval is reached, or equalization is activated immediately, the controller will enter the Equalize stage.
During equalization, the controller charges the battery until its voltage reaches the battery equalization voltage. Constant-voltage regulation then maintains this voltage until the set battery equalized time expires.
If the battery voltage does not reach the equalization voltage within the equalized time, the charge controller will extend the time. If the voltage is still low after the equalized timeout, the controller will stop equalization and return to the float stage.
6. Setting for Lithium Battery
6.1 Lithium Battery Connection
If using a lithium battery, ensure it is compatible with the inverter. There are two connectors on the lithium battery: the RS485 port of the BMS and the power cable.
Lithium Battery Connection Steps:
- Assemble battery terminals based on recommended cable and terminal sizes (similar to lead-acid battery connections).
- Connect the RS485 port of the battery's BMS to the BMS (RS485) communication port of the inverter.
RS485 Communication Port Pin Assignment:
| Pin number | RS485 Port |
|---|---|
| PIN1 | RS485-B |
| PIN2 | RS485-A |
| PIN7 | RS485-A |
| PIN8 | RS485-B |
6.2 Lithium Battery Communication and Setting
If using a lithium battery, connect the BMS communication cable between the battery and the inverter. This cable transmits information and signals, allowing the inverter to:
- Re-configure charging voltage, charging current, and battery discharge cut-off voltage based on lithium battery parameters.
- Start or stop inverter charging based on lithium battery status.
LCD Setting for Lithium Battery:
After connecting, complete and confirm the following settings:
- Select program 05 as lithium battery type.
- Confirm program 12/13/29/31/41/42 setting values.
Note: Programs 43/44/45 are only available with successful communication and will replace programs 12/13/29, which will become unavailable.
LCD Display Information (with successful communication):
- Communication successful icon (Li)
- Max lithium battery charging voltage
- Max lithium battery charging current
- Lithium battery discharging is forbidden (Li will flash once every 1 second)
- Lithium battery charging is forbidden (Li will flash once every 2 seconds)
- Lithium battery SOC(%)
6.3 Setting for PYLON US2000 Lithium Battery
Dip Switch Settings:
The PYLONTECH US2000 battery has 4 Dip Switches for baud rate and battery group address. 'OFF' is 0, 'ON' is 1. Dip 1 'ON' sets baud rate to 9600. Dips 2, 3, and 4 are for battery group address on the master battery.
Note: '1' is upper position, '0' is bottom position.
Installation Process:
- Use the RS485 cable to connect the inverter and Lithium battery.
- Switch on the Lithium battery.
- Press and hold for more than three seconds to start the Lithium battery (power output ready).
- Turn on the inverter.
- Select battery type as "Li2" in LCD program 5. If communication is successful, the battery icon 'Li' will light on the LCD display.
6.4 Setting for Lithium Battery Without Communication
This section provides guidance for lithium battery applications without BMS communication to prevent BMS protection issues. Complete these settings:
- Before starting: Obtain your battery's BMS specifications (Max charging voltage, Max charging current, Discharging protection voltage).
- Set battery type: Select "USE" (user-defined) in program 05.
- Set C.V voltage: Set program 26 (Bulk charging voltage) to Max charging voltage of BMS - 0.5V.
- Set floating charging voltage: Set program 27 (Floating charging voltage) to the C.V voltage.
- Set Low DC cut-off voltage: Set program 29 (Low DC cut-off voltage) to ≥ discharging protection voltage of BMS + 2V.
- Set Max charging current: Set program 02 (Max charging current) to a value less than the Max charging current of BMS.
- Set voltage point back to utility source: Set program 12 (Setting voltage point back to utility source) to ≥ Low DC cut-off voltage + 1V.
Remark: It is recommended to finish settings without turning on the inverter (just let the LCD show, no output). After finishing settings, restart the inverter.
7. Specifications
Image: A comprehensive table detailing the product parameters, including input/output specifications, charging modes, solar input parameters, and general specifications.
7.1 Table 1 Line Mode Specifications
| INVERTER MODEL | 4.2KVA |
|---|---|
| Input Voltage Waveform | Sinusoidal (utility or generator) |
| Nominal Input Voltage | 120Vac |
| Low Loss Voltage | 95Vac±7V (UPS); 70Vac±7V (Appliances) |
| Low Loss Return Voltage | 100Vac±7V (UPS); 75Vac±7V (Appliances) |
| High Loss Voltage | 140Vac±7V |
| High Loss Return Voltage | 135Vac±7V |
| Max AC Input Voltage | 150Vac |
| Nominal Input Frequency | 50Hz / 60Hz (Auto detection) |
| Low Loss Frequency | 40±1Hz |
| Low Loss Return Frequency | 42±1Hz |
| High Loss Frequency | 65±1Hz |
| High Loss Return Frequency | 63±1Hz |
| Output Short Circuit Protection | Battery mode: Electronic Circuits |
| Efficiency (Line Mode) | >95% (Rated R load, battery full charged) |
| Transfer Time | 10ms typical (UPS); 20ms typical (Appliances) |
7.2 Table 2 Inverter Mode Specifications
| INVERTER MODEL | 4.2KVA |
|---|---|
| Rated Output Power | 4.2KW |
| Output Voltage Waveform | Pure Sine Wave |
| Output Voltage Regulation | 120Vac±5% |
| Output Frequency | 50Hz or 60Hz |
| Peak Efficiency | 94% |
| Surge Capacity | 2* rated power for 5 seconds |
| Nominal DC Input Voltage | 24Vdc |
| Cold Start Voltage | 23.0Vdc |
| No Load Power Consumption | <55W |
| Low DC Warning Voltage (Just for AGM and Flooded) | 22.0Vdc (<20% load); 21.4Vdc (20-50% load); 20.4Vdc (>50% load) |
| Low DC Warning Return Voltage (Just for AGM and Flooded) | 23.0Vdc (<20% load); 22.4Vdc (20-50% load); 21.2Vdc (>50% load) |
| Low DC Cut-off Voltage (Just for AGM and Flooded) | 21.0Vdc (<20% load); 20.4Vdc (20-50% load); 19.2Vdc (>50% load) |
7.3 Table 3 Charge Mode Specifications
| Utility Charging Mode | |
|---|---|
| INVERTER MODEL | 4.2KVA |
| Max Charging Current (PV+AC) (@ VI/P=230Vac) | 120Amp |
| Max Charging Current (AC) (@ VI/P=230Vac) | 60Amp |
| Bulk Charging Voltage (Flooded Battery) | 29.2Vdc |
| Bulk Charging Voltage (AGM / Gel Battery) | 28.2Vdc |
| Floating Charging Voltage | 27Vdc |
| Overcharge Protection | 32Vdc |
| Charging Algorithm | 3-Step |
7.4 Table 4 General Specifications
| INVERTER MODEL | 4.2KVA |
|---|---|
| Operating Temperature Range | -10°C to 55°C |
| Storage temperature | -15°C~ 60°C |
| Humidity | 5% to 95% Relative Humidity (Non-condensing) |
| Dimension (D*W*H), mm | 368x312.4x120.5 |
| Net Weight, kg | 7.3 |
8. Troubleshooting
8.1 Fault Reference Code
| Fault Code | Fault Event | Icon on |
|---|---|---|
| 01 | Over temperature of inverter module | 01 |
| 02 | Over temperature of DCDC module | 02 |
| 03 | Battery voltage is too high | 03 |
| 04 | Over temperature of PV module | 04 |
| 05 | Output short circuited. | 05 |
| 06 | Output voltage is too high. | 06 |
| 07 | Overload time out | 07 |
| 08 | Bus voltage is too high | 08 |
| 09 | Bus soft start failed | 09 |
| 10 | PV over current | 10 |
| 11 | PV over voltage | 11 |
| 12 | DCDC over current | 12 |
| 13 | Over current or surge | 13 |
| 14 | Bus voltage is too low | 14 |
| 15 | Inverter failed (Self-checking) | 15 |
| 18 | Op current offset is too high | 18 |
| 19 | Inverter current offset is too high | 19 |
| 20 | DC/DC current offset is too high | 20 |
| 21 | PV current offset is too high | 21 |
| 22 | Output voltage is too low | 22 |
| 23 | Inverter negative power | 23 |
8.2 Troubleshooting Guide
| Problem | Explanation / Possible Cause | What to do |
|---|---|---|
| Unit shuts down automatically during startup process. | The battery voltage is too low. | 1. Re-charge battery. 2. Replace battery. |
| No response after power on. | 1. The battery voltage is far too low. 2. Battery polarity is connected reversed. |
1. Check if batteries and wiring are connected well. 2. Re-charge battery. 3. Replace battery. |
| Input voltage is displayed as 0 on the LCD and green LED is flashing. | Input protector is tripped. | Check if AC breaker is tripped and AC wiring is connected well. |
| Mains exist but the unit works in battery mode. | Insufficient quality of AC power (Shore or Generator). | 1. Check if AC wires are too thin and/or too long. 2. Check if generator (if applied) is working well or if input voltage range setting is correct (UPS→Appliance). |
| Mains exist but the unit works in battery mode. | Set "Solar First" as the priority of output source. | Change output source priority to Utility first. |
| When the unit is turned on, internal relay is switched on and off repeatedly. | Battery is disconnected. | Check if battery wires are connected well. |
| Fault code 07 | Overload error. The inverter is overloaded 110% and time is up. | Reduce the connected load by switching off some equipment. |
| Fault code 05 | Output short circuited. | Check if wiring is connected well and remove abnormal load. |
| Fault code 02 | Internal temperature of inverter component is over 100°C. | Check whether the air flow of the unit is blocked or whether the ambient temperature is too high. |
| Fault code 03 | Battery is over-charged. | Return to repair center. |
| Fault code 03 | The battery voltage is too high. | Check if spec and quantity of batteries meet requirements. |
| Fault code 06/22 | Output abnormal (Inverter voltage below 190Vac or higher than 260Vac). | 1. Reduce the connected load. 2. Return to repair center. |
| Fault code 08/09/15 | Internal components failed. | Return to repair center. |
| Fault code 13 | Over current or surge. | Restart the unit; if the error happens again, return to repair center. |
| Fault code 14 | Bus voltage is too low. | Restart the unit; if the error happens again, return to repair center. |
| Another fault code | If the wires are connected well, return to repair center. |
8.3 Warning Indicator
| Warning Code | Warning Event | Audible Alarm | Icon Flashing |
|---|---|---|---|
| 02 | Temperature is too High | Beep three times every second | 02 |
| 04 | Low battery | Beep once every second | 04 |
| 07 | Overload | Beep once every 0.5 second | 07 (OVERLOAD) |
| 10 | Output power derating | Beep twice every 3 seconds | 10 |
| 14 | Fan blocked | None | 14 |
| 15 | PV energy is low | Beep twice every 3 seconds | 15 |
| 19 | Lithium Battery communication is failed | Beep once every 0.5 second | 19 |
| 21 | Lithium Battery over current | None | 21 |
| 49 | Battery equalization | None | 49 |
| bP | Battery is not connected | None | bP |
9. User Tips
- Always ensure proper ventilation around the inverter to prevent overheating, especially during high load operation.
- Regularly check battery connections for tightness and corrosion to maintain optimal performance and safety.
- Utilize the Wi-Fi monitoring feature to keep track of your system's performance and identify potential issues early.
- When configuring lithium battery settings, double-check all parameters against your battery's BMS specifications to avoid damage.
- For optimal battery health, consider enabling the battery equalization function if your battery type supports it.