1. Introduction
Thank you for purchasing the Gaqqee Model 602 Carbon Monoxide (CO) Detector. This device is a single-station alarm designed to monitor the air for the presence of carbon monoxide. It features a digital display and an 85dB sound alert to warn you of dangerous CO levels. Please read this user manual thoroughly before use and keep it for future reference.
2. Product Features
- Flame-Retardant Material: Manufactured using ABS flame-retardant material, resistant to high temperatures and deformation.
- Gas-Sensitive Sensor: Electronic sensitive sensor capable of rapid detection and alarm activation, eliminating false alarms and missed detections.
- LCD Screen Display: Backlit digital display for gas concentration, providing clear and easy-to-read readings.
- Loud Alarm: Emits a loud 85dB alarm sound upon detection of dangerous CO levels.
- Permanent CO Sensor: Equipped with a durable, permanent carbon monoxide sensor.
- Battery Powered: Operates on 3 x 1.5V AA batteries (not included).
- Alarm Memory Feature: Stores the peak alarm level if an alarm occurs while you are away.
- Test/Reset Button: Allows for testing the unit's electronics and resetting the alarm.
3. Specifications
| Parameter | Detail | Parameter | Detail |
|---|---|---|---|
| Product Name | Carbon Monoxide Detector | Color | White |
| Application | Indoor | Mounting Type | Wall-mounted |
| Operating Voltage | DC 4.5V (3x 1.5V AA Batteries) | Operating Temperature | 0°C to 50°C |
| Standby Current | <50µA (without LCD); <200µA (with LCD) | Alarm Current | <75mA |
| Alarm Sound | 85dB | Detection Range | 0 ~ 999 PPM |
| Alarm Method | Audible + Visual (Red LED flash) | Detected Gas | CO (Carbon Monoxide) |
| Alarm Concentration | 100 - 150 PPM | Product Dimensions | 98 * 98 * 35 mm |
4. Setup and Installation
4.1. Battery Installation
- Remove the mounting bracket from the back of the alarm by twisting it.
- Open the battery door.
- Insert 3 x 1.5V AA batteries (not included) into the compartment, ensuring correct polarity.
- Close the battery door.
- CAUTION: Do not press the test/reset button while installing batteries, as this may prevent the unit from functioning correctly.
4.2. Recommended Installation Locations
IMPORTANT: This alarm must be mounted on a wall. Install only as detailed!
- For maximum protection, install an alarm on each level of a multi-level home, including every bedroom, hallways, finished attics, and basements.
- Place alarms at both ends of bedroom hallways or large rooms if the hallway or room is more than 30 ft (9.1 m) long.
- If you have only one alarm, ensure it is placed in the hallway outside of the main sleeping area, or in the main bedroom. Verify the alarm can be heard in all sleeping areas.
- Locate an alarm in every room where someone sleeps with the door closed, as a closed door may prevent the alarm from waking the sleeper.
- When mounting on the ceiling, locate it at a minimum of 4 inches (10 cm) from the side wall.
- If installing on the wall, mount it at a minimum of 4 inches (10 cm) and a maximum of 12 inches (30.5 cm) below the ceiling.
4.3. Locations to Avoid
Do not install the detector in:
- Garages, kitchens, furnace rooms, or bathrooms.
- Within 15 feet (4.5 meters) of any fuel-burning appliance.
- Within 3 feet (0.9 meters) of kitchen doors, bathrooms with tubs or showers, forced air ducts, ceiling/whole house ventilating fans, or other high airflow areas.
- Excessively dusty, dirty, or greasy areas.
- Damp and humid areas.
- Within one foot of fluorescent lights.
- Areas where the temperature is colder than 40°F (4.4°C) or hotter than 100°F (37.8°C).
- Near doors and windows that open to the outside.
- Peaks of vaulted ceilings, A-frame ceilings, or gabled roofs.
4.4. Mounting Instructions
- Remove the mounting bracket from the back of the alarm by twisting the alarm.
- After selecting the proper location, drill two Ø5.0mm holes in the ceiling or wall vertically with a distance of 60mm between them.
- Insert the plastic anchors into the holes.
- Attach the bracket to the plastic anchors with the arrow pointing down and screw tightly.
- Match the arrow on the back of the alarm with the arrow on the bracket to snap the alarm onto the bracket by twisting it.
5. Operation
5.1. Initial Power-Up
When batteries are installed, the unit will sound a 'chirp' and the red LED will flash once. The LCD will display "888" for 2 seconds, then "000" for 3 minutes during self-test mode, before entering normal operation mode.
5.2. LED Indicator Operation
- Green LED: Flashes every 30 seconds to indicate proper operation. If the green LED is out, the unit is malfunctioning.
- Red LED: Flashes in conjunction with the alarm beep when a dangerous level of carbon monoxide is detected.
5.3. LCD Display Indications
- "000" PPM: Displays during self-test or when CO leakage is less than 999ppm but over 30ppm, it shows the actual concentration.
- "Er": Indicates the unit is malfunctioning.
- "Lb": Indicates low battery and replacement is needed.
- "999ppm": Indicates CO level over 999ppm.
5.4. Testing the Alarm
Press the Test/Reset button for five seconds. A series of beeps will sound. The unit will sound 4 beeps every 5 seconds twice with red LED flashes. During the self-test mode, "000" displays on the LCD for 3 minutes and then enters normal operation mode. This test verifies proper unit operation.
CAUTION: Due to the loudness (85 decibels) of the alarm, always stand an arm's length away from the unit when testing.
5.5. What to Do If the Alarm Sounds
- Call emergency services immediately.
- Immediately move to fresh air outdoors or by an open door/window. Do a head count to ensure all persons are accounted for.
- Do not re-enter the premises or move away from the open door/window until emergency services responders have arrived, the premises have been aired out, and your alarm remains in its normal condition.
- Never restart the source of a CO problem until it has been fixed.
NEVER IGNORE THE ALARM! The CO sensor sensitivity and setting is:
- 50 ppm, alarms within 60 to 90 minutes
- 100 ppm, alarms within 10 to 40 minutes
- 300 ppm, alarms within 3 minutes
This carbon monoxide alarm is designed to detect carbon monoxide gas from ANY source of combustion. It is NOT designed to detect any other gas.
6. Maintenance
6.1. General Care
- Test the unit's alarm and LED light operation by pushing the test button once a week.
- Remove the unit from its mounting bracket and vacuum the alarm cover and vents with a soft brush attachment once a month to remove dust and dirt.
- REINSTALL IMMEDIATELY AFTER CLEANING AND THEN TEST USING THE TEST/RESET BUTTON!
- Never use detergents or other solvents to clean the unit.
- Avoid spraying air fresheners, hair spray, or other aerosols near the CO Alarm.
- Do not paint the unit. Paint will seal the vents and interfere with the sensor's ability to detect CO.
- Never attempt to disassemble the unit or clean inside. This action will void your warranty.
6.2. Battery Replacement
If the unit chirps once every 30 seconds with the green LED out or "Lb" displaying on the LCD, it indicates a low battery. Replace the batteries with qualified brands.
To replace the battery, first remove the alarm from the screws, then open the battery door, and directly replace the batteries. After installing or changing the battery, reinstall your alarm and test it.
7. Troubleshooting
| Problem | Indication | Solution |
|---|---|---|
| Unit Malfunctioning | Green LED is out, or "Er" displays on LCD. | Return the unit to the agent for repair. |
| Low Battery | One 'chirp' every 30 seconds, or "Lb" displays on LCD. | Replace all 3 AA batteries. |
| False Alarms / Sensor Damage | Alarm sounds without CO presence, or unit is unresponsive. | Ensure proper ventilation when using household cleaning supplies. Avoid placing the detector near substances that can affect the sensor (e.g., methane, propane, alcohol-based products, paints, hair spray, etc.). If issues persist, contact support. |
| Test Button Jammed | Button does not return to original position after pressing. | Gently pry the button free. Ensure no debris is obstructing the button mechanism. |
| Display Upside Down After Mounting | LCD display is inverted when mounted using keyhole slots. | Ensure the detector is oriented correctly during installation. The mounting bracket should allow for proper display orientation. |
8. User Tips
- Battery Life: Be aware that actual battery life may be shorter than theoretical estimates due to variations in current draw. Regularly check the 'Lb' indicator and perform weekly tests.
- Mounting Orientation: When using the keyhole slots for mounting, ensure the device is oriented so the LCD display is right-side up for easy reading.
- Test Button Care: Operate the test button gently to prevent it from jamming. If it feels stiff, check for any obstructions.