1. Introduction
The DATOUBOSS DT4855U is a multi-function inverter/charger that combines the capabilities of an inverter, solar charger, and battery charger to provide uninterruptible power support. Its compact design and comprehensive LCD display allow for user-configurable and easily accessible button operation for settings such as battery charging current, AC/solar charger priority, and acceptable input voltage ranges for various applications.
1.1 Key Features
- Pure sine wave output for stable and reliable power.
- Configurable input voltage range for home appliances and personal computers.
- Configurable battery charging current based on application needs.
- Configurable AC/Solar Charger priority.
- Compatible with mains voltage or generator power.
- Automatic restart when AC power recovers.
- Comprehensive protection against overload, over temperature, and short circuit.
- Smart battery charger design for optimized battery performance.
- Cold start function.
1.2 Basic System Architecture
The inverter is designed to integrate seamlessly into various off-grid and hybrid solar systems. A typical setup includes:
- Solar PV modules for power generation.
- External battery packs for energy storage.
- Connection to a generator or utility grid for supplementary power.
- Output to various home and office appliances.
2. Safety Instructions
WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.
- Before using the unit, read all instructions and cautionary markings on the unit, batteries, and all appropriate sections of this manual.
- CAUTION: To reduce the risk of injury, charge only deep-cycle lead-acid type rechargeable batteries. Other types of batteries may burst, causing personal injury and damage.
- Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
- To reduce the risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
- CAUTION: Only qualified personnel can install this device with a battery.
- NEVER charge a frozen battery.
- For optimum operation, follow required specifications to select appropriate cable sizes.
- Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts, which could cause an explosion.
- Strictly follow installation procedures when disconnecting AC or DC terminals. Refer to the INSTALLATION section for details.
- One 150A fuse is provided as over-current protection for the battery supply.
- GROUNDING INSTRUCTIONS: This inverter/charger should be connected to a permanent grounded wiring system. Comply with local requirements and regulations.
- NEVER short circuit AC output and DC input. Do NOT connect to the mains when DC input short circuits.
- Warning: Only qualified service persons are able to service this device. If errors persist after following the troubleshooting table, send this inverter/charger back to a local dealer or service center for maintenance.
3. Setup (Installation)
3.1 Unpacking and Inspection
Before installation, inspect the unit for any damage. The package should contain:
- Inverter Unit x 1
- User Manual x 1
- Wall Mounting Bracket & Screws x 1 set
3.2 Preparation
Before connecting any cables, remove the bottom cover of the inverter by unscrewing the two screws as shown in the diagram below (refer to original manual page 8 for diagram).
3.3 Mounting the Unit
Consider the following points for optimal installation:
- Do not mount the inverter on flammable construction materials.
- Mount on a solid surface.
- Install the inverter at eye level for easy LCD display readability.
- Allow a clearance of approximately 20 cm to the sides and 50 cm above and below the unit for proper air circulation and heat dissipation.
- The ambient temperature should be within the range of 20~35°C for optimal operation.
- Mount the unit vertically on a concrete or other non-combustible surface.
Secure the unit by screwing three screws. Use M6*80mm expansion bolts or M4/M5 screws.
3.4 Battery Connection
For safety and compliance, install a separate DC over-current protector or disconnect device between the battery and inverter. Ensure all wiring is performed by qualified personnel.
Recommended Battery Cable and Terminal Size:
| Rated Capacity | Typical Amperage | Battery Capacity | Wire Size | Cable (mm³) | Torque Value |
|---|---|---|---|---|---|
| 5.5KVA | 127A | 200AH | 1*2AWG / 2*6AWG | 34 / 14 | 2-3 Nm |
Insert battery wires flatly into battery connectors and tighten bolts with a torque of 2 Nm. Ensure correct polarity and securely screwed conductors.
WARNING: Shock Hazard! Installation must be performed with care due to high battery voltage in series.
CAUTION: Before making the final DC connection or closing the DC breaker/disconnector, ensure positive (+) is connected to positive (+) and negative (-) to negative (-).
3.5 AC Input/Output Connection
Install a separate AC breaker between the inverter and the AC input power source. This ensures the inverter can be disconnected for maintenance and protected from overcurrent.
CAUTION: Do not mis-connect input and output connectors. There are two terminal blocks marked "IN" and "OUT".
WARNING: All wiring must be performed by qualified personnel. Use appropriate cable for AC input connection.
Suggested Cable Requirement for AC Wires:
| Rated Capacity | Gauge | Torque Value |
|---|---|---|
| 5.5KVA | 8AWG | 1.4-1.6Nm |
Before making AC input/output connections, open the DC protector or disconnector first. Remove 10mm insulation from conductors. Insert AC input wires according to polarities and tighten terminal screws. Connect the PE protective conductor first.
3.6 PV Connection
Install a DC circuit breaker separately between the inverter and PV modules.
WARNING: All wiring must be performed by qualified personnel. Use appropriate cable for PV module connection.
Suggested Cable Requirement for PV Module Connection:
| Typical Amperage | Gauge | Torque Value |
|---|---|---|
| 30A | 12AWG | 1.4-1.6Nm |
When choosing PV modules, ensure the open circuit voltage (Voc) does not exceed the maximum PV array open circuit voltage of the inverter (500Vdc). The maximum supply voltage should be close to the optimal PV access voltage range (60-500Vdc) for best performance. If one PV module cannot meet this requirement, connect multiple PV modules in series. Check correct polarity of wires from PV modules and PV input connectors. Connect positive pole (+) to positive (+) and negative pole (-) to negative (-). Screw two wires tightly.
3.7 Parallel Function
The DT4855U inverter supports parallel operation for increased capacity. When installing multiple units:
- Mount all units at the same level, maintaining the specified clearances (20cm sides, 50cm top/bottom).
- Ensure all battery cables are of the same length to prevent voltage differences. Use a connector or bus-bar to join battery cables.
- Apply the same principle for AC input and output cable connections.
- For parallel operation in single phase, set "PAL" in LCD setting program 4.
- For split-phase systems, configure inverters for L1 and L2 phases using program 4 (e.g., "2L1" for L1, "2L2" for L2).
- For three-phase systems, a minimum of 3 inverters and a maximum of 9 are required. Configure inverters for L1, L2, and L3 phases using program 4 (e.g., "3P1" for L1, "3P2" for L2, "3P3" for L3).
- Do not connect current sharing cables between inverters in different phases to avoid damage.
3.8 Final Assembly
After connecting all wirings, replace the bottom cover by screwing the two screws back into place.
4. Operating Instructions
4.1 Power ON/OFF
Once the unit is properly installed and batteries are connected, simply press the On/Off switch (located on the bottom of the case) to turn on the unit.
4.1.1 Steps to Start Up
Connect the battery (voltage needs to be beyond 23V) or AC (ensure suitable input range based on output mode). Then, you can start up the inverter.
- Mains Power On: Connect to normal AC power, press the switch. The system will automatically turn on. If AC output power priority is set, the panel will display AC mode after a period, indicating successful startup.
- Battery Boot: Connect to battery, press the power-on button. The system will automatically turn on. If battery mode is set, the panel will display battery mode after a period, indicating successful startup.
4.1.2 Shutdown Steps
When the system is in battery mode or AC mode output, press the switch again to turn off the system.
4.2 Operation and Display Panel
The front panel features an LCD display, three indicators, and four function keys to show operating status and input/output power information.
4.2.1 LED Indicators
| Indicator | Color | Status | Message |
|---|---|---|---|
| AC/INV | Green | Solid On | Output is powered by utility in Line mode. |
| Flashing | Output is powered by battery or PV in battery mode. | ||
| CHG | Yellow | Solid On | Battery is fully charged. |
| Flashing | Battery is charging. | ||
| FAULT | Red | Solid On | Fault occurs in the inverter. |
| Flashing | Warning condition occurs in the inverter. |
4.2.2 Function Keys
| Function Key | Description |
|---|---|
| ESC | To exit setting mode |
| UP | To go to previous selection |
| DOWN | To go to next selection |
| ENTER | To confirm the selection in setting mode or enter setting mode |
4.2.3 LCD Setting Programs
After pressing and holding the ENTER button for 3 seconds, the unit will enter setting mode. Use the UP/DOWN buttons to select programs and ENTER to confirm or ESC to exit. Key settings include:
- Program 00: Exit setting mode.
- Program 01: Output source priority (Solar-Utility-Battery, Solar-Battery-Utility, Solar-Utility-Grid, Grid-Utility-Battery).
- Program 02: Maximum charging current (10A to max, 10A increment).
- Program 03: AC input voltage range (APL for appliances, UPS for sensitive electronics).
- Program 05: Battery type (AGM, Flooded, User-Defined, Lithium protocols).
- Program 08: ECO function (enables power saving when load is low).
- Program 09: Output frequency (50Hz/60Hz).
- Program 10: Output voltage (110V/120V).
- Programs 30-36: Battery Equalization settings (enable/disable, voltage, time, interval).
- Programs 39-41: Battery SOC related settings for lithium batteries.
- Programs 46-49: Scheduled charging/output times.
- Programs 51-55: Time and date settings.
- Programs 60-63: Dual output settings.
- Programs 71-72: Power grid peak shaving settings.
4.3 Battery Equalization
The equalization function reverses the buildup of negative chemical effects (stratification, sulfation) in batteries, which can reduce overall capacity. It's recommended to equalize batteries periodically.
To apply equalization:
- Enable battery equalization in LCD setting program 30.
- Set the equalization interval in program 35, or activate immediately in program 36.
5. Maintenance
Regular maintenance ensures the longevity and optimal performance of your inverter. Always disconnect all wirings before performing any maintenance or cleaning to prevent electric shock.
5.1 Environmental Conditions
Ensure the inverter operates within the following environmental parameters:
- Operating Temperature: -10~50°C
- Humidity: 20%-95% (Non-condensing)
- Storage Temperature: -15~60°C
- Altitude: Not over 1000m (derating over 1000m, max 4000m).
- Noise: ≤50db
5.2 Routine Checks
- Periodically check for any loose connections or damaged wiring.
- Ensure the cooling fan is free from obstructions and operating correctly. If a fan fault (Fault Code 01) occurs, replace the fan.
- Keep the inverter's vents clear to ensure proper airflow and prevent overheating.
- If internal components fail (Fault Codes 08/09/53/57), return the unit to a repair center.
6. Troubleshooting
This section provides guidance on common issues and their solutions. For persistent problems, contact a qualified service technician.
6.1 Fault Codes
When the inverter enters fault mode, the red LED light is always on, and the LCD displays a fault code. Refer to the table below for common fault codes:
| Fault Code | Fault Event |
|---|---|
| 60 | Power feedback protection |
| 71 | Firmware version inconsistent |
| 72 | Current sharing fault |
| 73 | Inconsistent output voltage settings in parallel-connected systems |
| 80 | CAN fault |
| 81 | Host loss |
| 82 | Synchronization loss |
| 83 | Battery voltage detected different |
| 84 | AC input voltage and frequency detected different |
| 85 | AC output current unbalance |
| 86 | AC output mode setting is different |
6.2 Common Problems and Solutions
| Problem | Explanation/Possible Cause | What to Do |
|---|---|---|
| Unit shuts down automatically during startup. | Battery voltage is too low (<1.91V/Cell). | 1. Re-charge battery. 2. Replace battery. |
| No response after power on. | 1. Battery voltage is far too low (<1.4V/Cell). 2. Internal fuse tripped. | 1. Contact repair center for fuse replacement. 2. Re-charge battery. |
| Mains exist but unit works in battery mode. | Insufficient quality of AC power (Shore or Generator). | 1. Check if AC wires are too thin/long. 2. Check generator or input voltage range setting. |
| When unit is turned on, internal relay switches on/off repeatedly. | Battery is disconnected. | Check if battery wires are connected well. |
| Buzzer beeps continuously and red LED is on. | Overload error (inverter overload 105% and time is up). | Reduce the connected load by switching off some equipment. |
| Output short circuited. | Check if wiring is connected well and remove abnormal load. | |
| Internal temperature of inverter component is over 120°C. | Check whether air flow is blocked or ambient temperature is too high. |
6.3 Alarm Descriptions
The red LED flashes, and the LCD displays an alarm code. The inverter does not enter the failure mode.
| Alarm Code | Alarm Event | Audible Alarm |
|---|---|---|
| 01 | Fan is locked when inverter is on. | Beep three times every second |
| 02 | Over temperature | None |
| 03 | Battery is over-charged | Beep once every second |
| 04 | Low battery | Beep once every second |
| 07 | Overload | Beep once every 0.5 second |
| 10 | Output power derating | Beep twice every 3 seconds |
| 15 | PV energy is low. | Beep twice every 3 seconds |
| 16 | High AC input (>140VAC) during BUS soft start | None |
| 27 | Max battery discharge current setting | None |
| E9 | Battery equalization | None |
| 6P | Battery is not connected | None |
7. Specifications
Model: DT4855U
| Feature | Specification |
|---|---|
| Rated Power | 5500W / 5500VA |
| DC Input Voltage | 48V |
| AC Output Voltage | 120V AC |
| Output Frequency | 60 Hz |
| Waveform | Pure Sine Wave |
| PV Open Circuit Voltage | 500V DC |
| MPPT Range | 60-500V DC |
| Max PV Input Power | 8500W |
| Max Charging Current | 100A |
| Conversion Efficiency | 0.9 |
| Operating Temperature | -10~50°C |
| Certification | CE, FCC, RoHS, pse, weee |
| Application | Off-Grid Solar System / Home Use |
8. User Tips
- Always ensure the rated power of your inverter is higher than the total wattage of the appliances you intend to connect.
- For inductive loads (e.g., motors, refrigerators), a pure sine wave inverter is crucial for stable operation and to prevent damage.
- Use standard battery cables to ensure full power output and prevent issues.
- Avoid overloading the inverter. If using appliances with high startup currents (like air conditioners), ensure the inverter's continuous power is 3-7 times higher than the appliance's rated power.
- Be aware that the inverter may not work well with LED bulbs due to their low power consumption and potential for flicker.
9. Warranty and Support
This device should only be serviced by qualified personnel. If errors persist after following the troubleshooting guide, please contact your local dealer or service center for maintenance and support.
A detailed user manual in PDF format is available for download: View User Manual (PDF)