meterk A8-O3

Contents

Portable Ozone Meter

Model: A8-O3

User Instruction Manual

1. Introduction

Thank you for choosing the Meterk Portable Ozone Meter. This device is designed to accurately measure ozone (O3) concentration, temperature, and humidity in various environments. Featuring a 2.8-inch full-color LCD screen, it provides real-time data, historical trends, and customizable alarm thresholds, making it an essential tool for monitoring air quality both indoors and outdoors.

2. Safety Information

  • WARNING: DO NOT IMMERSE IN WATER! This device is not waterproof.
  • Keep the device away from extreme temperatures and direct sunlight.
  • Do not attempt to open or modify the device, as this will void the warranty and may cause damage.
  • Use only the provided USB cable for charging.

3. Package Contents

Please check the package for the following items:

  • 1 x Portable Ozone Meter (Model A8-O3)
  • 1 x USB Charging Cable
  • 1 x Storage Bag
  • 1 x User Manual (English)

4. Device Overview

The Meterk Portable Ozone Meter features a user-friendly design with a clear display and intuitive controls.

4.1. Components

  • 2.8-inch Full-Color LCD Screen: Displays O3 concentration, temperature, humidity, battery status, and various settings.
  • Ozone Sensor: A plug-in and replaceable electrochemical sensor located at the top of the device.
  • MODE Button: Used to navigate through menus and settings.
  • Power Button: Turns the device on/off and confirms selections.
  • C/F Button: Toggles between Celsius and Fahrenheit temperature units.
  • Up/Down Navigation Buttons: Used for adjusting values and navigating menus.
  • USB Charging Port: Located on the side for charging the internal battery.
Front view of the Portable Ozone Meter showing the LCD screen with O3 reading, temperature, humidity, and control buttons.
Figure 1: Front view of the device with main display and buttons.
Diagram showing the pluggable electrochemical sensor of the ozone meter.
Figure 2: Illustration of the pluggable electrochemical sensor.

5. Setup

5.1. Charging the Device

Before first use, fully charge the device. Connect the provided USB charging cable to the device's USB port and plug the other end into a standard USB power adapter (5V/1A) or a computer's USB port.

  • The battery icon on the LCD screen will indicate charging status.
  • A full charge typically takes a few hours.
  • The device has a built-in 2500mAh lithium battery.
Images showing the ozone meter being charged via USB in a car, laptop, and with a power bank, highlighting the charging interface and sensor probe.
Figure 3: USB Charging options and device ports.

5.2. Powering On/Off

Press and hold the Power button for a few seconds to turn the device on or off.

6. Operating Instructions

The device provides real-time monitoring and various customizable features.

6.1. Real-time Monitoring

Upon powering on, the device will immediately begin displaying the current ozone concentration (O3 in PPM), temperature (°C/°F), and relative humidity (%RH) on the main screen.

  • An indicator (e.g., 'GOOD') will show the general air quality based on O3 levels.
  • The display also shows a bar graph indicating O3 levels relative to thresholds (e.g., 0.10, 0.30 PPM).

6.2. Menu Navigation and Settings

Press the MODE button to access the main menu. Use the Up/Down navigation buttons to scroll through options and the Power button to select.

Available settings include:

  • Alarm Set: Customize the O3 alarm threshold. When the gas concentration exceeds this value, the device will sound a buzzer and the digital display color will change.
  • Auto Shut Off: Set a timer for automatic device shutdown to conserve battery.
  • Brightness: Adjust the LCD display brightness from 5% to 100% (default is 60% at power on).
  • Record: View historical data. The device can store up to 100,000 pieces of data.
  • Storage: Manage data storage, including setting a timer for periodic data storage and deleting stored data.
  • Timed Storage: Configure intervals for automatic data logging.
  • Language: Select the display language.
The ozone meter displaying its setup menu options and graphs for O3 average per minute and real-time data.
Figure 4: Setup menu and data display graphs.

6.3. Temperature Unit Switching

Press the C/F button to toggle the temperature display between Celsius (°C) and Fahrenheit (°F).

6.4. Data Viewing and Analysis

The device can display historical data in graphical format, showing O3 average per minute and real-time O3 data trends over time.

7. Maintenance

7.1. Cleaning

Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure no liquids enter the sensor opening or charging port.

7.2. Sensor Replacement

The device uses a plug-in and replaceable electrochemical sensor. If sensor performance degrades over time, contact customer support for replacement options and instructions.

7.3. Storage

When not in use for extended periods, store the device in its provided storage bag in a cool, dry place, away from direct sunlight and extreme temperatures. Ensure the battery is partially charged (around 50%) before long-term storage.

8. Troubleshooting

  • Device does not turn on: Ensure the device is fully charged. If the issue persists, try connecting it to a power source and then attempting to turn it on.
  • Inaccurate readings: Ensure the sensor area is clear of obstructions. Move the device to a different location to rule out localized interference. If readings remain consistently inaccurate, the sensor may need calibration or replacement.
  • Screen is dim or unresponsive: Adjust the screen brightness in the settings. If unresponsive, try restarting the device.
  • Alarm not sounding: Check the alarm settings to ensure it is enabled and the threshold is set appropriately.

For further assistance, please contact customer support.

9. Specifications

Parameter Value
Model Number A8-O3
Detection Gas Ozone (O3)
Ozone Measurement Range 0-10.0 PPM
Temperature Measurement Range -9°C ~ 55°C (15.8°F ~ 131°F)
Humidity Measurement Range 0%RH ~ 100%RH
Display 2.8-inch TFT Full-Color LED Backlit LCD Screen
Sensor Type Plug-in and Replaceable Electrochemical Sensor
Battery Capacity 2500mAh Lithium Battery
Power Supply 5V/1A via USB
Main Engine Weight 200g
Work Environment -9°C ~ 55°C, <90%RH
Dimensions 180mm x 78mm x 32mm (7.08 x 3.07 x 1.25 inches)
Material ABS
Data Storage Capacity 100,000 pieces of data
Technical parameters table and dimensions of the ozone meter.
Figure 5: Technical Specifications and Dimensions.

10. User Tips

No specific user tips were available from provided reviews or Q&A content.

11. Warranty and Support

For warranty claims, technical support, or inquiries, please contact the manufacturer or their authorized representative:

Manufacturer Information:

  • Company Name: shanghai xi ao shi ye Co., Ltd.
  • Full Address: Room 1891, No. 1338-1, Huancheng South Road, Nanqiao Town, Fengxian District, Shanghai, China
  • Email: b154sumaito2806@163.com
  • Telephone: +86-13876659206

EU Authorized Representative:

  • AR Company Name: SOLID AUTHORITY LIMITED
  • Full Address: 51 Bracken Road, Sandyford, Dublin 18, D18 CV48, Ireland
  • Email: phoebe8706@gmail.com
  • Telephone: +33-761441379

For additional information, you may refer to the official user manual PDF: View User Manual PDF

© 2024 Meterk. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.