Thank you for choosing the ETENWOLF S0 Mini Bicycle Pump. This manual provides important information on how to safely and effectively use your new pump. Please read all instructions and safety warnings before use.

Package Contents

Ensure all items are present in the box:

ETENWOLF S0 Mini Bicycle Pump and accessories
Figure 1: What's in the box
  • ETENWOLF S0 Mini Bicycle Pump x1
  • Cone shaped nozzle x1
  • Ball needle x1
  • French copper adapter x1
  • T-shaped quick connector x1
  • Instruction manual x1

2. Product Overview

Familiarize yourself with the pump's components:

ETENWOLF S0 Mini Bicycle Pump with labeled parts
Figure 2: Product Overview
  1. Power On/Off Button
  2. "+" Pressure Increase Button
  3. "-" Pressure Decrease Button
  4. High-pressure Hose
  5. Target Input/Actual Pressure Display
  6. Battery Indicator
  7. Pressure Unit (PSI/BAR)
  8. Type-C Port

Note: The screen shows the target input value for 2 seconds upon power-on, then displays the actual pressure.

3. Setup

Initial Charging

Fully charge the pump before first use. Use a certified PD charger and the provided USB-C cable. Charging from 0% to 100% takes approximately 1-2 hours.

Battery Indicator (Charging)

  • 0-20% Orange light blinking
  • 20-99% White light blinking
  • 100% White light solid

Note: The pump will auto shut down after 5 minutes of inactivity when fully charged. It cannot be used while charging.

4. Operating Instructions

Quick Start Guide

Step-by-step inflation guide
Figure 3: Quick Start Guide
  1. Screw the nozzle end of the hose clockwise into the object to be inflated.
  2. Press the Power On/Off Button (1) to turn on the pump.
  3. Press the "+" and "-" buttons together to switch between PSI and BAR pressure units.
  4. Use the "+" and "-" buttons to increase or decrease the target pressure value.
  5. Press the Power On/Off Button (1) again to start inflation.
  6. The pump will automatically stop when the preset pressure is reached.

Checking Pressure

  1. Connect the nozzle end of the high-pressure hose to the object to be measured.
  2. Press the Power On/Off Button (1) to turn on.
  3. The screen will display the current pressure value.

Button Operation

Power On/Pause Button

  • Turn on: Long press the power button for 0.5 seconds.
  • Turn off: When the pump is on, long press the power button for 2 seconds.
  • Pause: When the pump starts inflating, press the power button again at any time to pause.

The pump will shut off automatically in the following cases:

  • Charging cable is accidentally disconnected.
  • Battery runs out.
  • 5 minutes of inactivity after full charge.

Preset Pressure and Memory

The screen displays both the target and actual pressure values. The default is 22 PSI, adjustable via "+" and "-". Each time you adjust the pressure, the system will remember your new target and unit. You can change the default at any time.

Battery Indicator (Discharging)

  • 0-10% Orange light blinking
  • 10-20% Orange light
  • 20-100% White light

Pressure Calibration

Different altitudes can cause pressure changes of 1-3 PSI. In high altitude areas (especially over 5000 ft / 1524 m), users can recalibrate the pump's sensor.

Calibration Steps:

  1. Press the power on/pause button.
  2. Hold both "+" and "-" buttons for 5 seconds.
  3. When the display blinks, calibration is successful.

Note:

  • Turn on the device before starting calibration.
  • The high-pressure hose must not be connected to anything during calibration, or it will fail.
  • Sufficient power or external source is needed for calibration.
  • No memory for new calibration settings. Once powered off, it resets to sea level (0 ft/m).
  • Above 5000 ft / 1524 m, manual calibration is needed each time the pump is turned on.

Inflation Methods and Adapters

Multifunctional pump with Presta and Schrader valve instructions
Figure 4: Inflation methods for various valves
  • Method 1 - Presta Valve: Simply assemble the Presta valve adapter to the hose nozzle.
  • Method 2 - T-shaped (Schrader Valve): Press and secure the air chuck directly onto the valve.

Included Adapters: Schrader Valve, Presta Valve, Balloon Adaptor, Inflation Needle.

Recommended pressure for bicycle, motorcycle, and basketball
Figure 5: Typical pressure ranges for common items
  • Bicycle: 25 - 100 psi
  • Motorcycle: 28 - 42 psi
  • Basketball: 4 - 13 psi

5. Maintenance

Charging Guidelines

For optimal charging performance and stability, use a certified PD charger and cable. Charging from 0% to 100% takes approximately 1-2 hours.

Storage

Please store the product within the temperature range of -4°F to 140°F (-20°C to 60°C). Extremely hot or cold environments may damage the battery and shorten the pump's lifespan. Long-term storage may reduce battery efficiency. Charge the pump at least once every three months to maintain good performance.

Cleaning

Use this product in a dry, clean environment. Dust intrusion may damage the product. Do not clean the product with water.

6. Troubleshooting

ProblemSolution
Inflation is slowCheck for leaks in the hose; ensure battery is charged.
Pump is on but not inflatingCheck if target pressure exceeds preset value.
Battery indicator doesn't show after chargingUse certified PD charger and try again.
Pump stopped due to extreme temperatureWhile charging, temperature must be 0°C-45°C (32°F-113°F). While inflating/deflating, temperature must be -20°C-74°C (-4°F-165°F).
Safety alert symbol lights up if abnormal pressure or motor errorTurn off the unit and restart after 10 minutes.
Pump is working but pressure reads zeroIf pressure <3 PSI, display shows 0 due to sensor limits.
Battery indicator varies from standby during use.Lithium battery voltage drops under load, causing this; it's normal.
Safety symbol shows E08If issue persists after reboot, contact factory for repair.
Displays error code E10Motor failure warning. May recover after blinking 30 sec. If not, send for repair.
Displays error code E11Low-temp charge icon: charging temp too low. Warm to above 0°C before charging.
Displays error code E12High-temp charge icon: let temp drop below 45°C before charging.
Displays error code E13Low-temp discharge icon: warm to >-20°C before use or charging others.
Displays error code E14High-temp discharge icon: cool below 58°C before use or output charging.
Display error code E15The air pump has exceeded the working time, the warning icon flashes for 30 seconds then returns to normal. Check if the inflated item is leaking.
Display error code E16Overpressure protection icon, returns to normal after releasing pressure.
Display error code E17High-pressure operation has exceeded working time, warning icon flashes for 30 seconds then returns to normal. Check if the inflated parts are functioning abnormally.
Display error code E18Battery damage warning icon and battery level indicator icon flash. After 30 seconds, the device will shut down. It is necessary to send the device to the factory.

7. Specifications

ParameterValue
ModelS0
Size94.8 x 75.2 x 40.2 mm
Inflation pressure range3.0 - 150.0 PSI / 0.20 - 10.34 bar
Operating temperatureCharging: 0°C - 45°C (32°F - 113°F)
Discharging: -20°C - 74°C (-4°F - 165°F)
Storage temperature-20°C - 60°C (-4°F - 140°F)
High-pressure hose length88 mm
Battery capacity2400 mAh (8.88 Wh)
Operating noiseBelow 85 dB within 1 meter range
InputType-C: 5V 2A
Working durationAbout 15 minutes at 25°C ambient temperature, within 20-50 PSI inflation pressure range
Charging time1-2 Hours
Sensor accuracy±1 PSI

8. Safety Instructions

  1. This product is not a toy and is not suitable for children. Users must be at least 16 years old. Keep children at a safe distance from the pump during inflation. The product contains a built-in lithium battery. Do not throw the product into fire or dispose of the battery improperly.
  2. Overheating damage or water ingress may increase the risk of fire or explosion. It is best to keep the product away from heat sources and not leave it in a hot car for long periods. If the pump becomes very hot, it may explode.
  3. Please store the product within the temperature range of -4°F to 140°F (-20°C to 60°C). Extremely hot or cold environments may damage the battery and shorten the pump's lifespan. Long-term storage may reduce battery efficiency. Charge the pump at least once every three months to maintain good performance.
  4. This product contains a built-in DC motor, which may produce sparks during use. Do not use in environments with explosive dust or gas.
  5. If there is unusual noise or the temperature becomes very high during inflation, please turn off the pump immediately.
  6. Before setting the inflation pressure, please ensure the correct pressure unit is selected. Mixing PSI and BAR may cause over-inflation and explosion.
  7. Unit conversion: 1 bar = 14.5 psi, 1 bar = 100 kPa.
  8. Do not leave the pump unattended while operating.
  9. Use this product in a dry, clean environment. Dust intrusion may damage the product. Do not clean the product with water.
  10. Always use a certified PD charger and the included charging cable to charge this product.
  11. To reduce the risk of electric shock, do not expose the device to rain; store it indoors. Failures caused by not following these requirements are not covered by the warranty.

9. User Tips

  • This pump is suitable for inflating various items, including bicycle tires, motorcycle tires, basketballs, and scooter tires.
  • Always double-check your target pressure setting to avoid over-inflation.

10. Warranty & Support

Warranty

Within two years of purchase, we provide timely and effective online after-sales service. We will repair or replace any defective product (due to manufacturing faults) within the warranty period.

Manufacturer

Guangdong Bestek Technology Co., Ltd
Address: No.1, North Gaopu 8th Road, Yuancheng Industrial Park, Heyuan City, Guangdong, P.R.China

Brand Owner

Mozhen Technology (Shenzhen) Co., LTD
Address: CN-503, Floor 5, Building 4, Tianan Yungu Industrial Park Phase II, Gangtou Community, Bantian Street, Longgang District, Shenzhen, Guangdong, CN

Contact Support

Phone: (1)877-838-0209 Mon-Fri 8AM-5PM (PST)
Email: support@etenwolf.com
Website: www.etenwolf.com

© 2024 ETENWOLF. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.