The Yieryi WIFI-YL01 Solar Wifi Zigbee 7-in-1 Pool Water Quality Monitor is designed to provide accurate and real-time monitoring of water quality in swimming pools, spas, aquaculture, fish tanks, and other water bodies. This smart floating analyzer measures pH, Chlorine (CL), Total Dissolved Solids (TDS), Oxidation-Reduction Potential (ORP), Salt, Electrical Conductivity (EC), and Temperature. With its solar charging capability and Zigbee wireless transmission, it offers convenient remote monitoring via a mobile application, ensuring optimal water conditions.

Safety Information

  • Ensure the device is properly sealed before submerging in water.
  • Do not leave the entire device fully submerged in water for extended periods, especially during heavy rain or fast-flowing water.
  • Remove the device from water after each measurement or at least once every 7 days during prolonged measurements to allow internal moisture to evaporate.
  • Keep calibration solutions out of reach of children and pets.
  • Avoid prolonged immersion of pH electrodes in acidic fluoride solutions and contact with silicone oil.

What's in the Box

Verify that all components are present:

Contents of the product package including the main monitor, gateway, cables, and buffer solutions.
Figure 1: Package Contents
  • 1 × Main Monitor Host
  • 1 × Zigbee Gateway
  • 1 × PH4.00 Calibration Solution
  • 1 × PH7.00 Calibration Solution
  • 1 × PH10.01 Calibration Solution
  • 1 × ORP Calibration Solution
  • 1 × Screwdriver
  • 1 × English Instruction Manual
  • 1 × Packaging Box

Product Overview

The WIFI-YL01 monitor features a floating design with a solar charging panel for continuous operation. It connects via Zigbee to a gateway, which then uses Wi-Fi to transmit data to your smartphone app. The device is equipped with newly upgraded electrodes for rapid response and extended lifespan.

Floating/Solar Water Quality Monitor showing its design and the parameters it measures.
Figure 2: Floating Design and Measured Parameters
Diagram highlighting the 7-in-1 features: Floating Design, WiFi Connect, Remote Monitor, Solar Charging, IPX7 Waterproof, and the measured parameters (CL, pH, SALT, ORP, TDS, EC, TEMP).
Figure 3: Key Features of the 7-in-1 Smart Pool Monitor
Close-up of the solar charging panel and newly upgraded electrodes for rapid response and extended lifespan.
Figure 4: Solar Charging Panel and Upgraded Electrodes

Key Features:

  • 7-in-1 Comprehensive Detection: PH, CL, ORP, SALT, EC, TDS, TEMP
  • Floating Design for easy deployment in water
  • Wi-Fi Connectivity (via Zigbee Gateway) for remote monitoring
  • Solar Charging for eco-friendly and continuous power
  • IPX7 Waterproof rating
  • Real-Time Remote Monitoring via Tuya Smart/Smart Life App
  • Customizable Upper & Lower Limit Alarm Reminders
  • Daily/Weekly/Monthly Historical Data Query
  • App Data Export to Excel & Email
  • Multi-Account Data Sharing and Multi-Device Management
  • Automatic Temperature Compensation
  • Upgraded High-Sensitivity Long-Lifespan Electrodes

Specifications

Parameter Measurement Range Resolution Accuracy
PH0.0-14.0 PH0.1 PH±0.1 PH
Chlorine (CL)0.0-4.0 mg/L0.1 mg/L±0.1 mg/L
ORP-999~+999 mV1 mV±15 mV
Salt0-999 ppm; 1000-9990 ppm1 ppm; 10 ppm±2% F.S
EC0-2000 μS/cm; 2000-9990 μS/cm; 10.01-19.99 mS/cm1 μS/cm; 10 μS/cm; 0.01 mS/cm±2% F.S
TDS0-999 ppm; 1000-9990 ppm1 ppm; 10 ppm±2% F.S
Temperature0.0-50.0°C; 32.0-122.0°F0.1°C / 0.1°F±0.1°C

Product Dimensions: Length 21 cm, Width 16.5 cm

Charging Mode: Solar Charging (also supports USB charging for the gateway)

Wireless Connection: Zigbee Long-Range 2.4Ghz Wireless Transmission, Compatible with Tuya & Smart Life App, supports Android & iOS System.

Setup

1. Remove Probe Protection Caps

  1. Remove the electrode cover by rotating clockwise.
  2. Remove the white pH electrode protection cover by turning clockwise.
  3. Remove the chlorine residual electrode maintenance cover downwards.
  4. Turn counterclockwise to close the green electrode protection cover.
Diagram showing the steps to remove the electrode covers and protection caps.
Figure 5: Removing Probe Protection Caps

2. App Download and Gateway Connection

The water quality monitor requires pairing with a smart gateway for operation. Download the Tuya Smart or Smart Life app on your smartphone.

Diagram showing the Zigbee wireless long-range transmission between the monitor, gateway, and smartphone app.
Figure 6: Zigbee Wireless Transmission Overview

App Connection Steps:

  1. Download the TUYA Smart APP.
  2. Connect your phone to a 2.4GHz Wi-Fi network (5GHz is not supported).
  3. Turn on your phone's Bluetooth.
  4. Connect the gateway to its power supply.
  5. Press and hold the RESET button on the gateway for 5 seconds. The indicator light will come on, and the red light will flash.
  6. Open the TUYA Smart APP and click to add a device.
  7. Select "Gateway Control" and then "Multifunctional Gateway (Zigbee)".
  8. Enter your 2.4GHz Wi-Fi password.
  9. Confirm that the indicator light on the gateway is flashing.
  10. The app will search for the device. Once found, click "Finish".

Video 1: Detailed steps for connecting the gateway to the app.

3. Add Sub-Device (Monitor)

  1. In the app, click on the added Zigbee Gateway.
  2. Click "Add sub-device".
  3. On the monitor, long press the reset button for 5 seconds. The indicator light will flash.
  4. In the app, confirm that the LED is blinking and proceed to search for the device.
  5. Once the monitor (BLE-YL01) is found and added successfully, click "Done" or "Finish".

Your monitor is now connected and ready for use.

Operation

1. Real-Time Monitoring

Once connected, the app will display real-time data for all 7 parameters. You can view daily, weekly, and monthly historical data.

Screenshot of the app showing daily, weekly, and monthly data viewing options.
Figure 7: Data Viewing in the App
Images showing remote viewing of data on a smartphone and data sharing functionality within the app.
Figure 8: Remote Viewing and Data Sharing

2. Setting Upper/Lower Value Limits and Alarms

You can set custom upper and lower limits for each parameter. If a measured value falls outside this range, the app will display the number in red and send an alarm message.

  1. In the app, navigate to the settings for the monitor.
  2. Select the option to set upper and lower limits.
  3. Adjust the desired values for each parameter.
  4. Confirm the settings.
Screenshots illustrating how to set upper and lower limits for water quality parameters in the app, and how out-of-range values are displayed in red.
Figure 9: Setting Limits and Alarm Display
Diagram showing how the app displays an alarm message and highlights out-of-range chlorine levels in red to maintain proper pool balance.
Figure 10: Chlorine Balance Monitoring and Alarms

3. Data Export

You can export historical data to Excel or email for further analysis.

  1. In the app, select the "Export" option.
  2. Choose the desired time frame (daily, weekly, or monthly).
  3. Enter your email address.
  4. The data will be sent to your email in an Excel format.
Screenshots showing the data export feature in the app, allowing users to select data for export to Excel via email.
Figure 11: Data Export Functionality

Calibration

Regular calibration ensures the accuracy of your monitor. Calibration solutions are included in the package.

1. pH Calibration

Two sets of pH calibration modes are available: 6.86/4.00/9.18 or 7.00/4.00/10.01.

  1. Uncap each pH Calibration Solution bottle (PH4.00, PH7.00, PH10.01).
  2. Open the YIERYI mart APP and enter the pH interface (ensure the device is already bound).
  3. Calibrating 7.00 pH: Wash the electrode with water and dry it. Place the pH electrode in the 7.00 solution. Wait for the value to stabilize, then click "Calibrate" in the app. The app will automatically recognize the solution, and 7.0 will appear, completing the 7.00 calibration.
  4. Calibrating 4.00 pH: Wash the electrode with water and dry it. Place the pH electrode in the 4.00 solution. Wait for the reading to stabilize, then click "Calibrate". The app will automatically detect the solution, and 4.0 will appear, completing the 4.00 calibration.
  5. Calibrating 10.01 pH: Wash the electrode with water and dry it. Place the pH electrode in the 10.01 solution. Wait for the reading to stabilize, then click "Calibrate". The app will automatically detect the solution, and 10.0 will appear, completing the 10.01 calibration.
Diagrams showing the step-by-step process of pH calibration using 7.00, 4.00, and 10.01 pH buffer solutions.
Figure 12: pH Calibration Process

2. ORP Calibration

  1. Pour the 222mV calibration solution into a clean cup. Wash the electrode with water and dry it.
  2. Put the electrode into the 222mV solution. Enter the ORP calibration interface in the app.
  3. Wait for the value to stabilize, then click "Calibrate". Set the value to 222. The app will display "calibration in progress" and then 222, completing the ORP calibration.
Diagrams showing the ORP calibration process using 222mV solution.
Figure 13: ORP Calibration Process

Maintenance

1. Electrode Care Precautions

  • pH Electrodes: Avoid prolonged immersion in acidic fluoride solutions. Avoid contact with silicone oil.
  • Cleaning: When cleaning glass electrodes, do not rinse directly with concentrated water. Use clean water gently.
  • Cross-Contamination: When measuring, avoid cross-contamination between solutions to maintain accuracy.
  • Contamination: If the electrode bulb is contaminated (e.g., by organic metal oxides, fats, proteins, pigments), the response rate will slow down. Clean with an appropriate solution based on the contaminant type.

2. pH Electrode Maintenance

Always keep the sponge moist. If the sponge is dry, add a few drops of KCL electrode protection solution to protect the electrode. Activate the electrodes at least once every 2 weeks to ensure accuracy and sensitivity.

Diagram showing how to maintain the pH electrode: remove protective cap, add KCL electrode protection solution if sponge is dry, and the activated pH electrode.
Figure 14: pH Electrode Maintenance

3. Chlorine Electrode Maintenance

Diagram showing how to maintain the chlorine electrode: remove protective cap, add KCL electrode protection solution if sponge is dry, and the activated chlorine electrode.
Figure 15: Chlorine Electrode Maintenance

4. Water Resistance Precautions

  • The product comes with a gateway and must be paired with it to function.
  • The latest version of the product is primarily solar-charged. If not exposed to sunlight for an extended period, place it in direct sunlight. Charging may take longer when the battery is low.
  • While the device is designed to be submerged, no product is 100% waterproof. The solar panel and sensor sections have enhanced water resistance, but care should be taken.
  • Do not leave the entire device fully submerged in water for extended periods. During heavy rain or in fast-flowing water, remove the device to prevent moisture ingress.
  • Avoid leaving the instrument submerged for several months. Remove it after each measurement. For prolonged measurements, remove it once every 7 days and place it in direct sunlight to evaporate internal moisture.

Troubleshooting

Q: Why isn't my machine waterproof?
A: After using the USB charging port or reset button, use the provided screwdriver to rotate the screw button to the firmest state to prevent loose leakage and machine failure.
Q: Why can't I connect to WiFi?
A: Ensure the device and your mobile phone are on the same 2.4GHz Wi-Fi network. The device does not support 5GHz Wi-Fi.
Q: Why is the residual chlorine value 0?
A: For the chlorine residual value to be displayed properly, the pool pH should be within 6.5-7.3 and the ORP should be within 650-750. If either of these values is outside the specified range, the chlorine value will not be displayed.
Q: What if the meter can't be calibrated?
A: If you encounter calibration issues, please contact customer support for assistance. As a professional manufacturer, we can provide detailed guidance or solutions.

User Tips

  • Replacement Electrodes: If you need replacement pH or other electrodes, contact the seller directly. They can provide information on purchasing accessories.
  • Solar Charging: For optimal performance, ensure the solar panel receives direct sunlight regularly. If the device has been in storage or a dark place, allow ample time for solar charging before use.
  • App Video Guides: If you have trouble with setup, usage, or calibration, contact the seller and provide your email address to receive video guides.

Warranty and Support

We are committed to providing high-quality service. If you have any questions or require support, please contact us directly. We aim to respond within 24 hours to ensure your satisfaction.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.