1. Product Overview
This is a 12mm panel-mount metal LED indicator light with screw terminal wiring, designed for direct installation in control cabinets, machinery, or equipment panels. The screw terminal design enables solder-free, quick on-site wiring, and the stainless steel housing provides water and corrosion resistance (typically IP65/IP67 rated).
- Mounting Cutout: Standard 12mm diameter hole
- Wiring Type: Screw terminal (M3/M4 screws, supports direct wire crimping)
- LED Colors: Red, green, blue, yellow, white (as shown in the product image)
- Operating Temperature: -25°C ~ +65°C
- Service Life: ≥50,000 hours
2. Specifications
The following table details the core specifications, which are voltage-specific. For a comprehensive guide, please refer to the official user manual PDF: User manual (PDF).
| Parameter | DC 12-24V Model | AC 220V (200-240V) Model |
|---|---|---|
| Rated Operating Voltage | DC 12V/24V (wide voltage) | AC 200-240V (50/60Hz) |
| Operating Current | ≤20mA (with built-in resistor) | ≤10mA (with built-in resistor) |
| Polarity Requirement | Polarity-sensitive (+/-) | Polarity-insensitive (no +/-) |
| Typical Applications | 12/24V DC equipment, automotive | 220V mains-powered devices |
3. Installation Steps
- Drill a 12mm diameter hole in your equipment panel (tolerance ±0.1mm); deburr the edges to avoid scratching the indicator housing.
- Insert the indicator light through the front of the panel, with the LED head facing outward.
- From the rear of the panel, thread the lock nut onto the indicator and tighten it by hand first, then use a spanner to secure it (do not over-tighten, as this may damage the thread or housing).
- Connect the wires to the screw terminals as per the voltage-specific wiring instructions below.
- Power on the system to test the indicator. If it lights up steadily, the installation is complete.
4. Wiring Instructions
4.1 DC 12-24V Model Wiring
This model is polarity-sensitive (has positive/negative terminals).
- Locate the two screw terminals on the back of the indicator, marked + (Positive) and - (Negative).
- Connect your DC power positive (12-24V) to the + terminal (usually marked with red or a + symbol).
- Connect your DC power negative (GND/0V) to the - terminal (usually marked with black or a - symbol).
- Tighten the terminal screws firmly to avoid loose connections (use a Phillips screwdriver, torque: 0.3-0.5N·m).
Note: Reversing the polarity will not damage the indicator, but it will not light up. Simply swap the wires to correct it.
4.2 AC 220V (200-240V) Model Wiring
This model is not polarity-sensitive (the two terminals are interchangeable).
- The two screw terminals have no +/- marking.
- Connect one terminal to the AC live wire (L) and the other to the AC neutral wire (N).
- Tighten the terminal screws securely.
Note: Do not connect this model to DC power (12/24V), as it will not light up and may be damaged by mismatched voltage/current.
5. Operating
Once correctly installed and wired according to the instructions, the LED indicator light will illuminate steadily when power is supplied to its terminals. The light will turn off when power is removed.
6. Maintenance
The QHJIA LED indicator lights are designed for long-term, maintenance-free operation. However, periodic checks can ensure optimal performance:
- Cleaning: If necessary, gently wipe the LED lens with a soft, damp cloth. Avoid abrasive cleaners.
- Connection Check: Periodically inspect the screw terminals to ensure wires remain securely fastened, especially in environments with vibration.
- Seal Integrity: For waterproof applications, ensure the lock nut and rubber sealing gasket remain tight and undamaged.
7. Troubleshooting
- Indicator does not light up (DC 12-24V model): Check for correct polarity. If the wires are reversed, the indicator will not light up. Swap the positive (+) and negative (-) connections.
- Indicator does not light up (AC 220V model): Ensure it is connected to an AC power source. Connecting an AC model to DC power will prevent it from lighting up and may damage the internal circuit.
- Indicator lights up dimly or flickers: Verify that the operating voltage matches the indicator's rated voltage. Incorrect voltage can lead to improper operation or damage.
- No light from any model:
- Ensure power is supplied to the circuit.
- Check wire connections for looseness or breaks.
- Confirm the indicator is not damaged.
8. Safety Guidelines
- Disconnect Power: Always disconnect all power before wiring or performing any maintenance to avoid electric shock, especially for the 220V AC model.
- Wire Insulation: Strip only 5-7mm of wire insulation. Ensure no bare copper is exposed outside the terminal to prevent short circuits.
- Voltage Matching:
- Never connect a DC 12-24V indicator to AC 220V power. This will immediately burn out the LED and may cause a short circuit.
- Never connect an AC 220V indicator to DC 12-24V power. It will not light up and may damage the internal circuit.
- Waterproof Installation: Ensure the rubber sealing gasket is installed between the indicator head and the panel. Tighten the lock nut fully to maintain the IP rating (prevents water/dust ingress).
- Environmental Limits: Avoid installing in high-vibration or highly corrosive environments, as this may loosen terminals or damage the housing.
9. User Tips
- Double-Check Voltage: Always confirm the voltage of your power source matches the indicator light's rating before connecting to prevent damage.
- Secure Connections: Ensure all screw terminal connections are tight to avoid intermittent operation or potential hazards.
- Proper Sealing: For outdoor or wet environments, pay extra attention to the rubber gasket and lock nut to maintain the IP66 waterproof rating.
- Color Coding: When working with DC models, use standard red for positive and black for negative wiring to avoid confusion.
10. Warranty and Support
QHJIA products are manufactured to high-quality standards. For any questions, technical support, or warranty claims, please contact the seller or manufacturer directly. Keep your purchase records for reference.