1. Introduction
This manual provides essential information for the safe and effective use of your Silicone Wire (Tinned Stranded Copper Conductor). Please read this manual thoroughly before installation, operation, or handling to ensure optimal performance and safety.
For a downloadable PDF version of this manual, please refer to the User Manual (PDF).

Figure 1: Flexible Silicone Wire Overview
2. Product Specifications
2.1 Basic Product Details
- Product Full Name: Silicone Wire (Tinned Stranded Copper Conductor)
- Model Number: Silicone Wire (AWG Size Range: 30AWG - 2AWG)
- Conductor Material: Tinned Oxygen-Free Copper (OFC), Multi-Strand Flexible Stranded Construction
- Insulation Material: Environmental-Friendly Silicone Rubber
- Rated Voltage: 600V
- Rated Temperature Range: -60°C to +200°C
- Test Voltage: 2000V AC
- Intended Application: Industrial Internal Wiring, Rechargeable Battery Packs, Electrical/Electronic Equipment Internal Circuits, Narrow Space Installation, High-Temperature Electrical Systems (Non-Telecommunication Use Only)
- Size Range: 30AWG ~ 2AWG
- Dimensional Tolerance: ±0.2mm

Figure 2: Product Information Summary
2.2 Performance Parameters Table (UL Flexible Silicone Wire)
| AWG Size | Conductor No. (Strand Specification) | Conductor Diameter (mm) | Outer Diameter (mm) | Electric Resistance (Ω/km) | Rated Current (A) | Packing Length /Roll |
|---|---|---|---|---|---|---|
| 30AWG | 11/0.08mm | 0.30mm | 0.8mm | 331Ω/km | 0.5A | 2300M |
| 28AWG | 16/0.08mm | 0.35mm | 1.2mm | 227Ω/km | 0.8A | 1500M |
| 26AWG | 30/0.08mm | 0.45mm | 1.5mm | 123Ω/km | 1.5A | 400M |
| 24AWG | 40/0.08mm | 0.6mm | 1.6mm | 97Ω/km | 2.0A | 400M |
| 22AWG | 60/0.08mm | 0.72mm | 1.7mm | 88Ω/km | 3.0A | 400M |
| 20AWG | 100/0.08mm | 0.92mm | 1.8mm | 62Ω/km | 5.0A | 400M |
| 18AWG | 150/0.08mm | 1.13mm | 2.3mm | 39Ω/km | 8.0A | 200M |
| 17AWG | 210/0.08mm | 1.15mm | 2.7mm | 30Ω/km | 10.5A | 200M |
| 16AWG | 252/0.08mm | 1.47mm | 2.3mm | 24Ω/km | 13A | 200M |
| 15AWG | 300/0.08mm | 1.55mm | 3.2mm | 20Ω/km | 15A | 200M |
| 14AWG | 400/0.08mm | 1.85mm | 3.5mm | 15Ω/km | 20A | 200M |
| 13AWG | 500/0.08mm | 2.00mm | 4.0mm | 12Ω/km | 25A | 100M |
| 12AWG | 680/0.08mm | 2.41mm | 4.5mm | 9Ω/km | 30A | 100M |
| 11AWG | 750/0.08mm | 2.53mm | 5.0mm | / | 55A | 100M |
| 10AWG | 1050/0.08mm | 2.90mm | 5.3mm | 6.3Ω/km | 55A | 100M |
| 8AWG | 1650/0.08mm | 3.50mm | 6.5mm | 4Ω/km | 66A | 100M |
| 7AWG | 2400/0.08mm | 4.50mm | 7.2mm | 3.9Ω/km | 96A | 100M |
| 6AWG | 3200/0.08mm | 5.20mm | 8.5mm | 1.2Ω/km | 128A | 100M |
| 4AWG | 5000/0.08mm | 7.20mm | 12.0mm | 1Ω/km | 200A | 50M |
| 2AWG | 10000/0.08mm | 9.24mm | 13.0mm | / | / | 50M |
Note: Diameter tolerance: ±0.2mm; All specification data is for reference only, subject to actual product inspection.

Figure 3: UL Flexible Silicone Wire (0.08mm) Specification Table
2.3 Soft Silicone 2Pins Wire Specifications
| Size | OD±0.2mm | Conductor No. | Insulation Thickness | Current | Voltage |
|---|---|---|---|---|---|
| 30AWG | 0.8mm | 11/0.08mmx2 | 0.25mm | 0.44A | 600V |
| 28AWG | 1.2mm | 16/0.08mmx2 | 0.42mm | 0.64A | 600V |
| 26AWG | 1.5mm | 30/0.08mmx2 | 0.50mm | 1.21A | 600V |
| 24AWG | 1.6mm | 40/0.08mmx2 | 0.51mm | 1.61A | 600V |
| 22AWG | 1.7mm | 60/0.08mmx2 | 0.49mm | 2.41A | 600V |
| 20AWG | 1.8mm | 100/0.08mmx2 | 0.44mm | 4.02A | 600V |
| 18AWG | 2.3mm | 150/0.08mmx2 | 0.58mm | 6.03A | 600V |
| 16AWG | 3.0mm | 252/0.08mmx2 | 0.76mm | 10A | 600V |
| 14AWG | 3.5mm | 400/0.08mmx2 | 0.82mm | 16A | 600V |
| 12AWG | 4.5mm | 680/0.08mmx2 | 1.04mm | 27A | 600V |

Figure 4: Soft Silicone 2Pins Wire Specification Table

Figure 5: Visual Comparison of AWG Sizes
3. Safety Information
Important Pre-Use Safety Notice
Read all safety instructions and specification details thoroughly before installation, operation, or handling. Failure to comply with these safety guidelines may result in product failure, electrical shock, fire hazards, or personal injury.
Warnings
- Choking Hazard: Keep this silicone wire and all cut segments out of reach of children under 3 years old. Small conductor strands and insulation fragments may cause choking; adult supervision is required for any handling or installation by minors.
- Electrical Safety Warning: This product is designed exclusively for fixed internal wiring and rechargeable battery connection applications. Do not use for outdoor exposed wiring, wet environment installations, or any application exceeding its rated 600V voltage or rated ampacity (refer to AWG size-specific current ratings in Section 2.2). Overloading beyond rated capacity will cause overheating and fire risks.
- Environmental Usage Limitations: Avoid prolonged exposure to direct intense sunlight, sharp abrasive surfaces, and corrosive chemicals. While the wire features extreme wide temperature resistance, avoid direct contact with open flames and heat sources exceeding 200°C.
- Pre-Use Inspection Requirement: Inspect the full length of the wire before each installation and use. Do not install or operate wires with damaged insulation, broken conductor strands, surface cracks, or physical deformation. Damaged wires must be discarded immediately to prevent electrical leakage and short circuits.
- Restricted Use Only: This silicone wire is strictly limited to its designated purpose: internal electrical wiring and rechargeable battery pack wiring for electrical and electronic equipment. Do not modify, splice, or reprocess the product without professional technical approval, and do not use for non-specified industrial or residential applications.
- Moisture & Humidity Protection: Avoid full immersion in water or prolonged exposure to high-humidity environments during operation and storage, as this will degrade insulation performance and cause electrical faults.

Figure 6: Temperature Resistance Test
4. Setup & Installation
4.1 Pre-Installation Preparation
- Verify Specifications: Confirm the selected AWG size, length, and specification fully match the equipment or battery system requirements prior to unpacking. Refer to the detailed parameter tables in Section 2 for complete data including conductor diameter, insulation thickness, electrical resistance, and rated current for each standard AWG size.
- Unpack and Inspect: Remove all outer packaging materials and protective films completely. Inspect the wire spool and wire body for any transportation-related damage, including insulation scratches or conductor breakage.
- Prepare Tools: Prepare professional wire stripping tools designed for silicone insulated wiring to prevent damage to tinned copper strands during the stripping process.

Figure 7: Wire in Original Packaging
4.2 Installation Steps
- Strip Insulation: Strip the silicone insulation to the appropriate length (avoid over-stripping to prevent exposed conductor short circuits), and ensure all tinned copper strands remain intact, untangled, and free of nicks.
- Connect Conductor: Connect the conductor firmly to designated terminals, battery poles, or electrical components, following standard industrial crimping or soldering procedures for battery wiring applications. Ensure secure, low-resistance connections to avoid poor contact and subsequent overheating.
- Route Wire: Route the wire neatly along equipment internal wiring channels; maintain a minimum bending radius compliant with UL wiring standards to avoid insulation cracking and conductor fatigue failure.
- Secure Wire: Secure the wire with suitable cable ties or mounting fixtures to prevent displacement, friction, or compression in narrow spaces, utilizing the wire's high flexibility for easy installation in compact equipment cavities.

Figure 8: Tinned Copper Core Detail

Figure 9: Silicone Insulator and Tinned Copper

Figure 10: Easy Separation of Paired Wires

Figure 11: Exposed Tinned Copper Strands
Video 1: Demonstration of Wire Flexibility and Tinned Copper Core
5. Operation
Once properly installed, the silicone wire is ready for operation within its intended applications. Ensure all connections are secure and the wire is routed without excessive strain or sharp bends. The wire's high flexibility allows for easy manipulation in tight spaces, making it suitable for complex internal wiring layouts.
Always operate within the rated voltage (600V) and current limits (refer to Section 2.2 for AWG-specific current ratings) to prevent overheating and ensure longevity.
6. Maintenance & Storage
6.1 Post-Installation Checks
- Visual Inspection: After installation is complete, conduct a full visual inspection of all connections and insulation integrity.
- Continuity Test: Perform a continuity test if required for the target electrical system to ensure proper electrical flow and connection.
6.2 Storage Guidelines
- Environment: Store unused wire in a dry, well-ventilated, and cool indoor environment.
- Protection: Keep away from direct sunlight, sharp objects, and corrosive substances.
- Packaging: Retain original spool packaging to prevent tangling and physical damage.
- Handling: Do not place heavy objects on wire spools, and avoid dragging the wire directly across rough surfaces to protect the silicone insulation layer from scratches and wear.
7. Troubleshooting
- Overheating: If the wire becomes excessively hot during operation, immediately disconnect power. Check if the current load exceeds the wire's rated ampacity (refer to Section 2.2). Ensure connections are secure and free from corrosion, which can increase resistance.
- Intermittent Connection: Inspect all connections for looseness or poor contact. Re-crimp or re-solder connections as necessary. Check for any physical damage to the wire or insulation.
- Insulation Damage: If insulation is cut, cracked, or melted, the wire should be replaced immediately. Do not attempt to repair damaged insulation as this can lead to electrical hazards.
- Wire Breakage: If conductor strands are broken, especially near connection points, replace the affected section of wire. Ensure proper strain relief is used in installations to prevent stress on the wire.
8. User Tips
- Easy Stripping: The silicone insulation is designed to be easily stripped, facilitating quick and efficient connections.
- Flexibility: The wire's soft and flexible nature makes it ideal for applications requiring tight bends or routing in confined spaces.
- Separable Paired Wires: For the 2-pin versions, the paired wires can be easily separated if your application requires individual conductors.
- Versatile Use: Excellent for various DIY electronics projects, RC models, LED lighting, and other applications requiring high-quality, flexible wiring.

Figure 12: Red and Black Paired Wire
9. Compliance Information
This product is classified as insulated appliance wiring material for industrial and rechargeable battery applications. It is not intended for telecommunication systems and is not fitted with modular telephone connectors.

Figure 13: Wire Features
10. Manufacturer & Support
10.1 Manufacturer Details
- Company: Shenzhen Tianshen Technology Co., Ltd
- Address: 19-A-J25, Building A, Guanghao International Center, Intersection of Meilong Road and Zhongmei Road, Daling Community, Minzhi Street, Longhua District, Shenzhen City, Guangdong Province 518000, P.R. China
- Phone: +86-13076627676
- Email: shenzhenskygod@163.com
10.2 EU Authorized Representative (EU AR) Details
- Company: ECLAT SOLUTION SARL
- Address: Bureau 1145, 37 Passage du Ponceau, 75002 Paris
- Contact Person: Elena Wang
- Phone: +33 187652619
- Email: eclatsolution@outlook.com