Gaqqee TS457 T459

Contents

Gaqqee TS457 T459 DC 5V Voltage Internal Resistance Tester User Manual

Model: TS457, T459 | Brand: Gaqqee

1. Introduction

This manual provides detailed instructions for the Gaqqee TS457 and T459 DC 5V Voltage Internal Resistance Testers. These devices are designed for high-precision measurement of voltage and internal resistance in lithium batteries using the 4-wire AC method. The testers offer features such as data storage, adjustable backlight, flexible standby time, and mobile app connectivity for enhanced functionality and ease of use.

2. Safety Information

  • Do not test AC power.
  • Do not test voltages above 45V.
  • Ensure the power supply voltage does not exceed DC 5V to prevent overvoltage damage.
  • When connecting the power supply, ensure proper insulation and correct polarity (thin red wire to positive, thin black wire to negative).

3. Product Features

  • High-Precision Measurement: Utilizes 4-wire AC method for accurate voltage and internal resistance readings.
  • Display Calibration: Supports fine-tuning of voltage and internal resistance display for precise results.
  • Data Storage: Stores up to 20 sets of internal resistance measurement data (T459) or 5 sets (TS457) for comparative analysis and reference.
  • Mobile App Connectivity (T459): Built-in Bluetooth for connection to a dedicated app, allowing display, settings, historical data viewing, and remote firmware updates.
  • Adjustable Backlight: 1-9 levels of backlight brightness adjustment for optimal visibility in various lighting conditions.
  • Energy Saving: Flexible standby time settings (1-9 minutes) to extend battery life.
  • Encoder Operation (T459): Efficient and fast operation with a high-gloss aluminum knob cap for a good operating feel.
  • Reserved Interfaces: Communication interface supporting MODBUS protocol and expandable serial port screen. NG/OK external signal ports for automation equipment docking.
  • Automatic Judgment: Upper and lower threshold values can be set for automatic qualification judgment.

4. Specifications

Parameter Specification
Model Number TS457 T459 DC 5V Voltage Internal Resistance Tester
DIY Supplies Electrical
Power Source DC
Battery Included No
High-concerned chemical None
Origin Mainland China
Working Voltage DC 5V (Do not supply power with overvoltage)
Test Principle AC 4-Wire Method
Voltage Test Range 0.001V ~ 45.00V
Voltage Resolution 0.001V
Internal Resistance Measurement Range (T459) 0.1mΩ ~ 7.999Ω
Internal Resistance Measurement Range (TS457) 0.1mΩ ~ 6.999Ω
Internal Resistance Resolution 0.1mΩ
Data Recording (T459) Supports 20 sets (last 5 viewable on device, all on app)
Data Recording (TS457) Supports 5 sets
Automatic Shutdown 1-9 minute standby time adjustment
Backlight Brightness 1-9 levels adjustment
Product Size (T459) 79mm x 43mm x 26mm
Installation Opening (T459) 75mm x 38mm
Product Size (TS457) 79.5mm x 42.1mm x 27.8mm
Installation Opening (TS457) 77mm x 39.3mm
Product Weight Net weight 38g, with packaging 64g

5. Package Contents

  • Internal Resistance Tester (TS457 or T459) x 1
  • XH-2.54-3P Red/Black/Yellow Power Supply Cable (150mm) x 1
  • XH-2.54-4P Signal Acquisition Cable (400mm) x 1

6. Setup

6.1 Power Supply Methods

The tester can be powered using one of the following methods:

  1. DC 5V Power Supply: Connect a DC 5V power source directly to the device.
  2. 18650 Battery Two-Wire Power Supply: Connect an 18650 battery directly. Ensure correct polarity: thin red wire to the positive electrode, thin black wire to the negative pole. The yellow wire indicates charging status and should not be connected normally. Ensure proper insulation.
  3. 18650 Battery + Power Adapter Board: Use an 18650 battery in conjunction with a power adapter board (purchased separately).
Diagram showing two power supply methods: direct DC 3.5V-5V connection and 18650 battery with adapter board.
Figure 6.1: Two Power Supply Methods (DC5V or 18650 battery)

6.2 Kelvin Clamp Connection (for T459)

Before use, prepare a 5V power supply or 18650 battery. Use the XH-2.54-4P signal acquisition cable to create a test fixture or purchase additional accessories like an XH2.54-4P to Kelvin clamp or an XH2.54-4P battery test stand.

Diagram showing how to connect Kelvin clamps to the XH2.54-4P terminal on the back of the meter for testing a component.
Figure 6.2: Clamp Test Demonstration

Connect the XH2.54-4P plug into the 4P terminal on the back of the meter. Attach Kelvin clamps to both ends of the component being tested.

6.3 Battery Test Stand Setup

If using a battery test stand (e.g., with XH2.54-4P adapter), connect the negative pole of the top battery to the active end and the positive pole of the top battery to the fixed end of the test stand.

Diagram showing a battery inserted into a test stand with connections to the tester.
Figure 6.3: Test Using a Battery Test Stand

7. Operating Instructions

7.1 Power On/Off

When powered on for the first time and no internal resistance or voltage is detected, the device will automatically shut down after the set standby time (default 9 minutes). You can also long-press the ON/OFF button to manually shut down. Click the ON/OFF button to turn the device on.

7.2 Main Interface Navigation

The device features different interfaces for measurement, data recording, and settings. Navigation is typically done using the knob and buttons (TS457) or the encoder knob (T459).

Screenshots of the tester's interface showing voltage and resistance readings, data recording, and pass/fail results.
Figure 7.1: Interface Display Examples
  • Main Interface 1: Displays voltage and resistance when not measured or during measurement.
  • Main Interface 2: Automatic judgment of measurement results (Pass/Fail) based on set thresholds.
  • On the internal resistance record page, turn the knob left to enter the sorting/judgment page.
  • On the sorting/judgment page, turn the knob right to enter the internal resistance record page.

7.3 Data Recording

On the internal resistance record page, after measuring voltage and internal resistance, click the knob button to record the measured values. The interface displays a count (1 to 20). Only the last 5 sets of data are viewable on the device, but all recorded data can be accessed via the mobile app (T459).

7.4 Menu Settings

To enter the settings menu, long-press the knob button for 3 seconds from the internal resistance record page. Rotate the knob to switch between menu options (selected font will be green). Click the knob to select an option (font changes to red) and then rotate to adjust the setting. Click again to confirm and save.

Screenshot of the T459 menu settings interface showing language, voltage reference, resistance reference, standby, brightness, reset, OTA, and exit options.
Figure 7.2: Menu Settings Interface (T459)
  • Language Settings: Select 'LANGUAGE' to switch between Chinese and English.
  • Voltage Calibration (VOL-REF): Adjusts the displayed voltage value. This does not affect the actual voltage.
  • Internal Resistance Calibration (RES-REF): Adjusts the displayed internal resistance value. This does not affect the actual resistance.
  • Standby Time Adjustment (STANDBY): Sets the automatic shutdown time from 1 to 9 minutes.
  • Backlight Brightness Adjustment (BRIGHTNESS): Adjusts screen brightness from 1 to 9 levels.
  • Restore Factory Settings (RESET): Prompts to confirm factory reset. 'OK' will be displayed upon completion.
  • OTA Firmware Update (T459): Select 'OTA' to enter firmware upgrade mode. Follow app instructions for remote updates.
  • Exit Settings: Select 'EXIT' to return to the main interface.

7.5 Upper/Lower Limit Setting

On the sorting judgment page, long-press the knob button for 3 seconds to enter the upper/lower limit setting interface. Rotate the knob to switch between selecting upper or lower limit settings. Rotate the knob to change the setting data. After completion, click the knob button to confirm and save. Long-press the knob button to exit.

  • Upper/lower limit setting data will not be saved when turned off and needs to be reset.
  • The upper limit setting data must be greater than the lower limit setting data; otherwise, the system will set both to be equal.

7.6 Screen Display Flipping

On the internal resistance record page, hold down the knob button and turn the knob to the right to flip the page display.

7.7 Mobile App Connection (T459)

The T459 model supports connection to a dedicated mobile app for extended functionality.

  1. Open the Wuzhi Zhilian app and enable Bluetooth on your phone.
  2. Click "Add Device" on the app interface. It will automatically search for "ZK-T459".
  3. Click on "ZK-T459" to connect. The device display will show a connection successful message.
  4. Click the device icon in the app to enter the normal operation interface.
  5. You can long-press the product icon in the app to change the device name or delete it.
Screenshot of the T459 connected to a mobile app, showing voltage, resistance, and settings options.
Figure 7.3: Dedicated App Support (T459)

Watch the product demonstration video for a visual guide on operation and app connectivity:

Play video
Watch video online
Video 7.1: Product Demonstration and App Connection

8. Maintenance

  • Keep the device clean and dry. Wipe with a soft, dry cloth.
  • Avoid exposing the device to extreme temperatures, humidity, or direct sunlight.
  • Store the device in a safe place when not in use to prevent physical damage.
  • Regularly check cable connections for wear or damage.

9. Troubleshooting

  • Device not powering on: Check power supply connections and ensure the voltage is within the DC 5V limit.
  • Inaccurate readings: Ensure proper 4-wire connection to the component. Perform voltage and internal resistance calibration via the settings menu if necessary.
  • Mobile app connection issues (T459): Ensure Bluetooth is enabled on your phone and the app. Try restarting both the device and the app. Make sure the device is within range.
  • Screen display problems: Adjust backlight brightness in the settings menu. If the display is flipped, use the screen flipping function.

10. User Tips

  • For the most accurate internal resistance measurements, always use the 4-wire method and ensure good contact with the test probes.
  • Utilize the data storage function to track battery performance over time, which can be helpful for identifying degradation or comparing different batteries.
  • Take advantage of the mobile app (T459) for a more comprehensive view of data and easier management of settings and firmware updates.

11. Support

For further details, advanced troubleshooting, or specific technical inquiries, please refer to the official user manual PDF. A PDF version of the user manual is available for download.

Note: The official user manual (PDF) can be found at: https://manuals.plus/m/54715d07ec42674a0fa077ba6098c4ffd3cc5da4b3de9bdc53253dd6bf90ffaa

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.