1. Product Overview
The HLK-LD2416 is an ultra-compact AiP (Antenna in Package) human presence sensor from the Hi-Link 24G radar series. It integrates an optimized 24GHz radar sensing algorithm (firmware 2416) and a human presence detection algorithm, enabling it to accurately detect both sitting and lying stationary humans.
This module boasts a maximum sensing range of 7.5 meters for moving humans. It allows for easy configuration of sensing range, trigger and hold thresholds for different distance zones, and inactivity reporting delay. Supporting both GPIO and UART interfaces, it offers plug-and-play functionality and can be flexibly applied to various smart scenarios and end products. A key feature is its automatic detection threshold generation, which reduces manual calibration efforts, improves detection accuracy, simplifies installation procedures, and facilitates large-scale deployment.
2. Product Features and Benefits
- Smart Design: Equipped with a single-chip intelligent AiP mmWave sensor SoC, with built-in antenna and intelligent algorithms.
- Ultra-compact Size: Sensor dimensions: 14 mm × 14 mm.
- Plug-and-Play: Pre-configured with default human presence sensing settings for immediate use.
- Compliant Frequency Band: Operates in the 24 GHz ISM band, certified for FCC, CE, and China’s radio spectrum regulations.
- Power Supply: 5V power input.
- Low Power Consumption: Average operating current of 80 mA.
- Multi-function Detection: Effectively detects moving, micro-moving, and stationary humans, with real-time reporting of detection results.
- Easy Integration: SoC with integrated antenna enables simple design and shorter production cycles.
- Visual Configuration: Includes a visual tool for flexible setup of detection distance ranges and target disappearance delay time, with support for automatic threshold generation.
- Sensing Range Management: Supports configurable sensing zones to effectively filter out interference outside the defined range.
- No Dead Zone Detection: Detects presence as close as 0.2 m.
- Wide Coverage: Detection angle of ±60° for broad monitoring coverage.
- Flexible Installation: Supports multiple mounting options, including ceiling and wall mounting.
- Independent Configuration: Trigger and hold states can be configured independently for strong anti-interference performance.
- Enhanced Environmental Resistance: Moisture-proof, corrosion-resistant, and anti-static for improved adaptability to harsh environments.
3. Application Scenarios
The HLK-LD2416 module can detect and identify moving, standing, and stationary humans, making it suitable for various AIoT scenarios:
- Smart Home: Detects human presence and distance, reporting results to enable intelligent control of home appliances.
- Smart Business: Detects human approach or departure within a set distance range, instantly activating screens or devices and keeping them active while presence is detected.
- Smart Security: Ideal for access control systems, building intercoms, electronic door viewers, and similar security applications.
- Smart Lighting: Identifies and detects human presence with precise location detection, suitable for public lighting equipment such as sensor lights and bulb lights.
4. Specifications
| Parameter | Value |
|---|---|
| Model | HLK-LD2416 |
| Type | PLC Positioning Modules |
| Brand Name | Hi-Link |
| Transmit Frequency | 24 GHz (24.00-24.25 GHz ISM band) |
| Modulation | FMCW |
| Input Voltage | 5V |
| Working Current | 80mA (Average) |
| Sensing Distance | 0.2 - 7.5m |
| Detection Angle | ±60° |
| Data Interface | TTL Serial |
| Baud Rate | 115200 |
| Mounting Options | Ceiling Mounting / Wall Mounting |
| Size | 14 x 14mm |
| Certifications | FCC, CE, SRRC |
For a comparison with other Hi-Link radar modules, please refer to the following table:
5. Setup and Installation
5.1 Module Dimensions
5.2 Mounting Options
The HLK-LD2416 supports both ceiling and wall mounting, offering flexibility for various application environments.
5.2.1 Ceiling Mounting
When mounting the module on the ceiling, ensure the sensor has a clear line of sight to the detection area. The sensing range can be affected by installation height.
Important Note: As the installation height decreases, the maximum sensing range gradually narrows. Refer to the diagram below for visual guidance.
5.2.2 Wall Mounting
For wall mounting, position the module at an appropriate height (e.g., 1.5-2.0m) to cover the desired detection zone effectively.
6. Operating Instructions
The HLK-LD2416 module is designed for plug-and-play operation with default settings optimized for human presence detection. For advanced customization, a visual configuration tool is available.
6.1 Powering On
Connect the module to a stable 5V power supply. Ensure correct polarity to prevent damage.
6.2 Data Interface
The module supports both GPIO and TTL Serial interfaces for communication. Connect the appropriate pins to your main control unit (MCU) or development board.
- GPIO: For simple ON/OFF state reporting (presence detected/not detected).
- TTL Serial: For detailed data output, including detection results, distance information, and configuration commands. The default baud rate is 115200.
6.3 Configuration
The module can be configured using a dedicated visual tool (software provided by Hi-Link). This tool allows you to:
- Adjust detection distance ranges.
- Set trigger and hold thresholds.
- Configure inactivity reporting delay.
- Utilize automatic threshold generation for simplified setup.
- Define specific sensing zones to filter out unwanted interference.
Refer to the official software documentation for detailed instructions on using the visual configuration tool.
7. Maintenance
- Keep the module clean and free from dust and debris.
- Avoid exposing the module to extreme temperatures or humidity beyond its specified operating conditions.
- Ensure proper ventilation if enclosed in a casing to prevent overheating.
- Do not attempt to disassemble the module, as this may void the warranty and cause damage.
8. Troubleshooting
- No Detection:
- Check power supply (5V).
- Ensure the module is correctly oriented towards the detection area.
- Verify that the sensing range and thresholds are configured appropriately for your environment using the visual tool.
- Check for any physical obstructions in front of the sensor.
- False Detections:
- Adjust sensing zones to exclude areas with unwanted movement (e.g., pets, curtains moving due to drafts).
- Increase the trigger threshold sensitivity if necessary.
- Ensure the module is securely mounted to prevent vibrations.
- Communication Issues (UART):
- Verify correct wiring of TX/RX lines.
- Confirm the baud rate (115200) matches your host device.
- Check for any loose connections.
9. User Tips
- For optimal performance, avoid placing the module directly facing large metallic objects or surfaces that could cause radar reflections.
- Experiment with different mounting heights and angles to achieve the best coverage for your specific application.
- Utilize the visual configuration tool to fine-tune sensitivity and detection zones, especially in complex environments.
- Regularly check for firmware updates from Hi-Link to ensure you have the latest features and improvements.
10. Warranty and Support
For detailed warranty information and technical support, please refer to the official Hi-Link documentation and resources.
A comprehensive user manual in PDF format is available for download: HLK-LD2416 User Manual (PDF).
You can also find additional technical resources and support on the Hi-Link website: ask.hiktech.net.