1. Product Overview
The SONGGER U96P USB Voltage and Current Tester is designed for real-time monitoring of USB charging performance. This device accurately measures voltage, current, power, accumulated capacity, energy, impedance, temperature, and timing data. It supports the detection of multiple fast-charging protocols, making it an essential tool for engineers, technicians, quality control personnel, and electronics enthusiasts.
Featuring an integrated IPS true color display, the tester provides clear data visualization. Its low-resistance sampling design ensures high measurement accuracy, even for high-current applications.

Figure 1: SONGGER USB Voltage and Current Tester showing real-time measurements. Supports up to 6.5A High Current and various Fast Charging Protocols.
2. Safety Information and Precautions
2.1. General Safety Warnings
- WARNING! Risk of electric shock. Use only within the specified low-voltage DC range (3.60V to 30.0V).
- High current operation may cause heat generation. Avoid prolonged use above 5A.
- Do not connect to non-USB high-voltage power systems or AC mains directly.
- Do not use the device if the housing is damaged.
- Keep out of reach of children.
- Proper disposal: Follow WEEE directives for electronic waste.
2.2. Usage Precautions
- Ensure the input voltage remains within 3.60V to 30.0V DC.
- Do not exceed the maximum measurement current of 5.1A to avoid overheating or internal damage. The hardware tolerance is up to 6.5A, but continuous operation above 5.1A is not recommended.
- This device is intended for low-voltage USB systems only.
- Avoid using the device in environments with condensation, excessive humidity, or explosive atmospheres.
- Do not disassemble or modify the device. Unauthorized modifications will void any potential warranty.
- Keep the device away from strong electromagnetic interference sources.
- Children should not operate this device without adult supervision.
3. Package Contents
Please check the package for the following items:
- 1 x SONGGER USB Voltage and Current Tester (Model U96P)
Note: Additional accessories, if any, will be listed on the product packaging.
4. Product Features
- 1mΩ Ultra-Low Sampling Resistance: Ensures highly accurate current detection for high-load devices.
- Supports Up to 6.5A High Current: Accurately measures up to 5.1A; ideal for testing power banks and fast chargers.
- Fast-Charging Protocol Detection: Automatically recognizes FCP, SCP, DCP, AFC, Apple, and QC charging protocols.
- Multi-Mode One-Key Reset: Long-press for full reset; double-tap to clear energy, triple-tap for capacity, four taps for time.
- IPS True Color Screen with Flip Function: Wide-view 160×80 display that supports screen rotation for flexible reading angles.
- Real-Time USB Cable & Device Monitoring: Measures charging efficiency of cables, smartphones, power banks, and adapters.
- Power-Off Data Memory: Automatically saves test data even after unplugging. Supports 9 sets of power-off storage.
- Durable All-Metal Housing + High-Brightness Backlight: Strong and clear display in any lighting condition.
5. Setup and Connection
5.1. Preparation
Ensure the USB tester is clean and free from any physical damage before use.
5.2. Connecting the Tester
- Connect the USB tester's male USB plug into your power source (e.g., a USB charger, power bank, or computer USB port).
- Connect your load device (e.g., smartphone, tablet, USB fan, or other USB electronic device) into the USB output port of the tester.
- Ensure that the input current does not exceed 5.1A during measurement to prevent damage to the device.

Figure 2: Example connection of the USB tester between a power source and a load device. The tester displays fast charge recognition details.
6. Operating Instructions
6.1. Power On and Initial Display
Once connected, the display will automatically power on and show real-time voltage, current, and power data. The device will also automatically detect supported fast-charging protocols and display related information if applicable.

Figure 3: Xuanwei Multi-Screen Interface Design. This diagram illustrates the various display modes including Startup, Enlarged Display, Custom Interfaces, USB Four-Wire Detection, Backend Calibration, Screen Rotation, and Color Display On/Off.
6.2. Data Reading
You can read the following parameters in real-time on the IPS display:
- Voltage (V): Input voltage from the power source.
- Current (A): Current drawn by the load device.
- Power (W): Real-time power consumption (Voltage x Current).
- Accumulated Capacity (mAh): Total milliamp-hours delivered over time.
- Accumulated Energy (mWh): Total milliwatt-hours delivered over time.
- Impedance (Ω): Calculated resistance of the circuit.
- Temperature (°C): Internal temperature of the device.
- Timing: Duration of the measurement session.
Accumulated capacity and energy values will continuously increase during measurement. Temperature and impedance readings are displayed simultaneously for diagnostic reference.
6.3. Data Reset Functions
Use the multi-press key operation for data reset:
- Long press: Performs a full reset of all accumulated data (capacity, energy, timing).
- Double press: Clears only the accumulated energy (mWh).
- Triple press: Clears only the accumulated capacity (mAh).
- Four presses: Resets only the timing data.
6.4. Screen Rotation Function
The screen supports rotation for optimal viewing regardless of the device's insertion angle. Short press the multi-function button to switch to the 'AAA' interface, then long press to rotate the screen orientation.

Figure 4: Screen Rotation and Display On/Off Function. The screen can be rotated for convenience, and the display can be turned off while charging continues.
6.5. Display On/Off Function
Short-press the multi-function button to switch to the standby screen (display off), while still allowing the device to charge normally. This is useful for charging at night. The display can be reactivated with a single button press.
6.6. Power-Off Memory
The device features a power-off storage function. When the power bank or charger is disconnected, the tester can store up to 9 sets of previously accumulated data. This temporarily saves current capacity during power loss. When restarted, it will continue accumulating from the previously used capacity. If accumulation is not needed, the stored data can be manually cleared using the reset functions.

Figure 5: Power-Off Memory & Data Storage Function. The tester retains measurement data even after being disconnected, supporting up to 9 sets of data.
7. Maintenance
- Storage: Store the device in a dry, dust-free environment within -20°C to +70°C.
- Handling: Avoid mechanical shock or strong vibration.
- Cleaning: Clean the housing with a soft, dry cloth. Do not use solvents or corrosive cleaning agents.
- Long-Term Storage: If the device is not used for an extended period, store it in anti-static packaging.
8. Troubleshooting
- Display Not Turning On: Ensure the tester is properly connected between a live power source and a load device. Check if the power source is active.
- Inaccurate Readings: Verify all connections are secure. Ensure you are not exceeding the maximum current (5.1A) or voltage (30.0V) limits. Keep the device away from strong electromagnetic interference.
- Data Not Resetting: Carefully follow the multi-press key operations for the specific data you wish to reset (long press for all, double for energy, triple for capacity, four for time).
- Fast Charge Protocol Not Detected: Ensure both the charger and the device being charged support a fast-charging protocol. Note that 100% accurate identification cannot be guaranteed due to rapid updates in mobile phone technologies.
9. Specifications
| Parameter | Value |
|---|---|
| Voltage Measurement Range | 3.60V ~ 30.0V |
| Current Measurement Range | 0.00A ~ 5.10A (Max hardware tolerance: 6.5A) |
| Capacity Accumulation Range | 0 ~ 99999mAh |
| Energy Accumulation Range | 0 ~ 99999mWh |
| Power Measurement Range | 0.00W ~ 150.00W |
| Impedance Measurement Range | 1 ~ 999.9Ω |
| Temperature Measurement Range | 0 ~ 80°C |
| Timing Range | 999 hours 59 minutes 59 seconds |
| Input Interface | 5A High-Current USB Port (USB-A) |
| USB D+ Voltage Range | 0V ~ 2.99V |
| USB D- Voltage Range | 0V ~ 2.99V |
| Refresh Time | >500ms / time |
| Measurement Rate | Approx. 0.5 times / second |
| Display Type | 12,800-Pixel IPS True Color Digital LCD |
| Screen Resolution | 160 × 80 |
| Self-Consumption Current | <0.02A |
| Operating Temperature | -10 ~ +60°C |
| Operating Humidity | 10 ~ 80% (No Condensation) |
| Operating Air Pressure | 80 ~ 106kPa |
| Sampling Resistance | 1mΩ |
| Supported Fast-Charging Protocols | FCP, SCP, DCP, AFC, Apple 2.4A, QC series |
10. User Tips
- Accurate Capacity Testing: For precise capacity testing of power banks, ensure the power bank is fully charged before starting the test and fully discharged during the test.
- Fast Charging Confirmation: When testing fast charging, observe the protocol detection displayed on the screen to confirm that the expected fast-charging protocol is active.
- Data Logging: For critical measurements, it is advisable to note down the readings before performing any reset operations, especially a full reset.
- Calibration: Do not attempt to calibrate the device without a standard 5V voltage and 2A constant current source, as this may disrupt default values. Refer to the Smart Hardware Repair section in Figure 6 for details.

Figure 6: Smart Hardware Repair and Subtle Software Calibration Technology. Provides instructions for entering calibration mode and restoring factory settings.
11. Warranty and Support
For technical support, warranty inquiries, or bulk orders, please contact the seller directly using the information below:

Figure 7: Contact Information for SONGGER. Includes WhatsApp and Email for support and inquiries.
WhatsApp: +86 13311678550
Email: miazhao008@gmali.com
This document is provided for product instruction purposes only and does not constitute legal advice. The seller is responsible for ensuring compliance with destination market regulations.
12. Product Video Overview
Video 1: Official product overview video showcasing the manufacturing process and applications of SONGGER sensors and measurement devices.