Gaqqee 10 in 1 USB Type-C Tester

Contents

Gaqqee 10-in-1 USB Type-C Tester Instruction Manual

Model: 10 in 1 USB Type-C Tester

Brand: Gaqqee

1. Product Overview

The Gaqqee 10-in-1 USB Type-C Tester is a versatile digital instrument designed for real-time monitoring and testing of various electrical parameters of charging devices. It provides comprehensive data including current, voltage, power, capacity, resistance, timing, and temperature. This tester supports a wide range of fast charging protocols, making it compatible with numerous USB and Type-C digital devices such as chargers, data cables, power banks, notebooks, and mobile phones. Its high-definition IPS true color digital LCD screen ensures clear display of multiple parameters simultaneously. The device also features data logging capabilities, storing up to 9 sets of measurement data for battery capacity calculation, and offers customizable voltage and current alarms.

Gaqqee 10-in-1 USB Type-C Tester showing various measurement values
Figure 1: Front view of the Gaqqee 10-in-1 USB Type-C Tester displaying voltage, current, power, and other parameters.

2. Setup and Connection

To begin using your USB Type-C Tester, ensure proper connection to avoid malfunction. The device acts as an intermediary between your power source and the device you wish to test.

General Connection Method:

  • Connect the INPUT terminal of the tester to your power supply (e.g., wall charger, power bank).
  • Connect the OUTPUT terminal of the tester to the device you wish to charge/test (e.g., mobile phone, tablet, notebook).

Important: Incorrect connection will prevent the product from functioning. Always connect the input to the power source and the output to the load.

Specific Interface Notes:

  • USB, Type-C interface models: "INPUT" connects to the power supply, "OUTPUT" connects to the load.
  • USB+Type-C interface models: The USB input connects to the USB output, and the Type-C input connects to the Type-C output. Note that the Type-C interface will not display readings if there is no load connected.
Play video
Watch video online
Video 1: Demonstration of connecting the USB Type-C Tester to a charger and a mobile phone, showing real-time data display.
Diagram showing the ports and buttons of the USB Type-C Tester
Figure 2: Detailed analysis of the tester's interfaces, including Type-C Input Port, Type-C Output Port, 8A high current USB Input Port, USB Output Port, Mode key, and On/Off Key.

3. Operating Instructions

The tester features a multi-function button for navigating screens and managing data.

Button Functions:

  • Short press the mode button: Switches between different display screens (e.g., main display, USB four-wire function screen, alarm settings).
  • Quickly triple-tap the switch button: Resets the accumulated power (mWh) to zero and resets the timing to zero for the current group (0.00).
  • Long press the on/off button for 2 seconds: Changes the cumulative data storage group number (NO.X). The tester can record up to 9 sets of measurement data.

Screen Navigation and Settings:

  1. Power On Display: Upon powering on, the main display panel shows various parameters like voltage, current, power, and time.
  2. Functional Interface: Short press the mode button to cycle through different functional interfaces, including the USB four-wire function screen.
  3. Alarm Settings (Voltage/Current):
    • To enter high/low voltage or current alarm settings, navigate to the respective screen by short-pressing the mode button.
    • When the actual value (voltage or current) exceeds or falls below the set alarm threshold, the corresponding value on the main screen will blink.
    • Adjusting Alarm Values: Press and hold the key to make the number jump. Click the key to adjust the value. Double-click the key to move to the next digit. Press and hold the key again to exit the setting mode.
  4. Display On/Off (Hibernation): Short press the multi-function key to switch to a hibernation screen interface for an off display. This allows for charging overnight without screen light. A single press will re-wake the display.
Image showing multi-function key operation instructions for screen switching, resetting, and changing data groups.
Figure 3: Visual guide for multi-function button operations, including short press for screen switching, triple-tap for resetting data, and long press for changing data storage groups.
Screenshots of various display interfaces including functional interface, USB 4-wire interface, and voltage/current warning pages.
Figure 4: Examples of the tester's display interfaces, showing functional data, USB 4-wire data, and alarm pages for high/low voltage and current.

4. Key Features

Real-time Monitoring:

The tester provides real-time detection of the charging status of electrical appliances, displaying charging voltage, current, and other parameters at a glance. This allows for immediate assessment of charging performance.

USB Voltage and current meter showing real-time detection of charging status
Figure 5: Real-time display of USB voltage and current, indicating the charging status of connected devices.

Multiple Data Logging:

The device can record up to 9 sets of measurement data, which is useful for battery capacity calculation and long-term monitoring. This data can be used as a relative value for analysis.

Image showing multiple data logging screens for battery capacity detection
Figure 6: The tester's capability to log multiple sets of data for detailed analysis of battery capacity.

Fast Charging Protocol Detection:

The tester automatically detects and supports various fast charging protocols, including PD2.0, 3.0, PPS, QC2.0, 3.0, AFC, PE, FCP, SCP, Apple 2.4A/2.1A/0.5A, and Android DCP/AFC. This ensures compatibility with a wide range of modern devices and helps improve charging efficiency.

Image showing the tester detecting multiple fast charging protocols
Figure 7: The tester automatically identifying and supporting various fast charging protocols.

High Precision Measurement:

Engineered for precision, the tester provides accurate measurements comparable to large-scale laboratory instruments, ensuring reliable data for evaluation.

Image showing the USB Type-C Tester being compared against professional laboratory instruments for precision testing.
Figure 8: The tester undergoing voltage precision evaluation against specialized laboratory instruments.

5. Specifications

Parameter Value
Voltage Measurement RangeDC 4.5~36V
Current Measurement Range0-5A / 0-8A
Capacity Totalization Range0-99999mAh
Power Accumulation Range0-99999mWh
Power Measurement Range0-150W
Impedance Measurement Range1-999.9Ω
Temperature Measurement Range0-80°C
Timing Time999 hours and 59 minutes
Input Interface5A high current USB interface / Type-C interface
Output InterfaceUSB / Type-C
USB D+ Voltage Range0~2.99V
USB D- Voltage Range0~2.99V
Refresh Time>500mS/times
Measurement RateAbout 0.5 times/second
DisplayIPS true color digital LCD screen
Self-consumption Current<0.02A
Operating Temperature-10~60°C
Working Humidity10~80%RH (no condensation)
Working Air Pressure80~106kPa
Product Dimensions (USB)77.6 x 27 x 11 mm
Product Dimensions (Type-C)73.6 x 27 x 11 mm
Product Dimensions (USB+Type-C)76.9 x 38 x 11 mm
Diagram showing the dimensions of the USB Type-C Tester
Figure 9: Dimensions of the USB Type-C Tester (74mm/2.91in length, 28mm/1.10in width, 13mm/0.51in thickness).

6. User Tips

  • Understanding Display Modes: Familiarize yourself with the different display screens by short-pressing the mode button. Each screen provides unique data or settings.
  • Resetting Counters: If you need to clear accumulated power (mWh) or timing data for a new measurement, quickly triple-tap the switch button. This is useful for testing individual charging cycles.
  • Alarm Configuration: Utilize the voltage and current alarm settings to protect your devices or monitor specific charging conditions. Remember to long-press the button to adjust values and exit the setting mode.
  • Testing PD Chargers: When testing a PD charger, ensure an output device (like a cell phone or another PD-compatible device) is connected to the tester's output port for the screen to light up and display readings.

7. Troubleshooting

  • No Display/Product Not Working:
    • Ensure the input terminal is correctly connected to a power source and the output terminal is connected to a load. Incorrect connection is a common cause of non-functionality.
    • For Type-C interfaces, if no load is connected, the display may not show any readings. Connect a device to the output.
    • If testing a PD charger, an output device must be connected for the screen to activate.
  • Inaccurate Readings:
    • Ensure all connections are secure and free from debris.
    • The tester is designed for high precision, but external factors like cable quality can affect readings. Try using different cables.
  • Device Arrived Damaged: If the product arrived broken or is faulty upon initial use, please contact the seller or manufacturer for support.

8. Maintenance

  • Cleaning: Use a soft, dry cloth to clean the device. Avoid using liquids or abrasive cleaners.
  • Storage: Store the tester in a cool, dry place away from direct sunlight and extreme temperatures.
  • Handling: Handle the device with care to prevent physical damage. Avoid dropping or subjecting it to strong impacts.

9. Warranty and Support

For warranty information, technical support, or any product-related inquiries, please refer to the seller's policies or contact the manufacturer directly. Keep your purchase receipt as proof of purchase.

A user manual in PDF format may also be available for download from the seller's product page or manufacturer's website. (Reference: User manual (PDF))

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.