1. Product Overview
The Gaqqee 10-in-1 USB Type-C Tester is a versatile digital instrument designed for real-time monitoring and testing of various electrical parameters of charging devices. It provides comprehensive data including current, voltage, power, capacity, resistance, timing, and temperature. This tester supports a wide range of fast charging protocols, making it compatible with numerous USB and Type-C digital devices such as chargers, data cables, power banks, notebooks, and mobile phones. Its high-definition IPS true color digital LCD screen ensures clear display of multiple parameters simultaneously. The device also features data logging capabilities, storing up to 9 sets of measurement data for battery capacity calculation, and offers customizable voltage and current alarms.
2. Setup and Connection
To begin using your USB Type-C Tester, ensure proper connection to avoid malfunction. The device acts as an intermediary between your power source and the device you wish to test.
General Connection Method:
- Connect the INPUT terminal of the tester to your power supply (e.g., wall charger, power bank).
- Connect the OUTPUT terminal of the tester to the device you wish to charge/test (e.g., mobile phone, tablet, notebook).
Important: Incorrect connection will prevent the product from functioning. Always connect the input to the power source and the output to the load.
Specific Interface Notes:
- USB, Type-C interface models: "INPUT" connects to the power supply, "OUTPUT" connects to the load.
- USB+Type-C interface models: The USB input connects to the USB output, and the Type-C input connects to the Type-C output. Note that the Type-C interface will not display readings if there is no load connected.
3. Operating Instructions
The tester features a multi-function button for navigating screens and managing data.
Button Functions:
- Short press the mode button: Switches between different display screens (e.g., main display, USB four-wire function screen, alarm settings).
- Quickly triple-tap the switch button: Resets the accumulated power (mWh) to zero and resets the timing to zero for the current group (0.00).
- Long press the on/off button for 2 seconds: Changes the cumulative data storage group number (NO.X). The tester can record up to 9 sets of measurement data.
Screen Navigation and Settings:
- Power On Display: Upon powering on, the main display panel shows various parameters like voltage, current, power, and time.
- Functional Interface: Short press the mode button to cycle through different functional interfaces, including the USB four-wire function screen.
- Alarm Settings (Voltage/Current):
- To enter high/low voltage or current alarm settings, navigate to the respective screen by short-pressing the mode button.
- When the actual value (voltage or current) exceeds or falls below the set alarm threshold, the corresponding value on the main screen will blink.
- Adjusting Alarm Values: Press and hold the key to make the number jump. Click the key to adjust the value. Double-click the key to move to the next digit. Press and hold the key again to exit the setting mode.
- Display On/Off (Hibernation): Short press the multi-function key to switch to a hibernation screen interface for an off display. This allows for charging overnight without screen light. A single press will re-wake the display.
4. Key Features
Real-time Monitoring:
The tester provides real-time detection of the charging status of electrical appliances, displaying charging voltage, current, and other parameters at a glance. This allows for immediate assessment of charging performance.
Multiple Data Logging:
The device can record up to 9 sets of measurement data, which is useful for battery capacity calculation and long-term monitoring. This data can be used as a relative value for analysis.
Fast Charging Protocol Detection:
The tester automatically detects and supports various fast charging protocols, including PD2.0, 3.0, PPS, QC2.0, 3.0, AFC, PE, FCP, SCP, Apple 2.4A/2.1A/0.5A, and Android DCP/AFC. This ensures compatibility with a wide range of modern devices and helps improve charging efficiency.
High Precision Measurement:
Engineered for precision, the tester provides accurate measurements comparable to large-scale laboratory instruments, ensuring reliable data for evaluation.
5. Specifications
| Parameter | Value |
|---|---|
| Voltage Measurement Range | DC 4.5~36V |
| Current Measurement Range | 0-5A / 0-8A |
| Capacity Totalization Range | 0-99999mAh |
| Power Accumulation Range | 0-99999mWh |
| Power Measurement Range | 0-150W |
| Impedance Measurement Range | 1-999.9Ω |
| Temperature Measurement Range | 0-80°C |
| Timing Time | 999 hours and 59 minutes |
| Input Interface | 5A high current USB interface / Type-C interface |
| Output Interface | USB / Type-C |
| USB D+ Voltage Range | 0~2.99V |
| USB D- Voltage Range | 0~2.99V |
| Refresh Time | >500mS/times |
| Measurement Rate | About 0.5 times/second |
| Display | IPS true color digital LCD screen |
| Self-consumption Current | <0.02A |
| Operating Temperature | -10~60°C |
| Working Humidity | 10~80%RH (no condensation) |
| Working Air Pressure | 80~106kPa |
| Product Dimensions (USB) | 77.6 x 27 x 11 mm |
| Product Dimensions (Type-C) | 73.6 x 27 x 11 mm |
| Product Dimensions (USB+Type-C) | 76.9 x 38 x 11 mm |
6. User Tips
- Understanding Display Modes: Familiarize yourself with the different display screens by short-pressing the mode button. Each screen provides unique data or settings.
- Resetting Counters: If you need to clear accumulated power (mWh) or timing data for a new measurement, quickly triple-tap the switch button. This is useful for testing individual charging cycles.
- Alarm Configuration: Utilize the voltage and current alarm settings to protect your devices or monitor specific charging conditions. Remember to long-press the button to adjust values and exit the setting mode.
- Testing PD Chargers: When testing a PD charger, ensure an output device (like a cell phone or another PD-compatible device) is connected to the tester's output port for the screen to light up and display readings.
7. Troubleshooting
- No Display/Product Not Working:
- Ensure the input terminal is correctly connected to a power source and the output terminal is connected to a load. Incorrect connection is a common cause of non-functionality.
- For Type-C interfaces, if no load is connected, the display may not show any readings. Connect a device to the output.
- If testing a PD charger, an output device must be connected for the screen to activate.
- Inaccurate Readings:
- Ensure all connections are secure and free from debris.
- The tester is designed for high precision, but external factors like cable quality can affect readings. Try using different cables.
- Device Arrived Damaged: If the product arrived broken or is faulty upon initial use, please contact the seller or manufacturer for support.
8. Maintenance
- Cleaning: Use a soft, dry cloth to clean the device. Avoid using liquids or abrasive cleaners.
- Storage: Store the tester in a cool, dry place away from direct sunlight and extreme temperatures.
- Handling: Handle the device with care to prevent physical damage. Avoid dropping or subjecting it to strong impacts.
9. Warranty and Support
For warranty information, technical support, or any product-related inquiries, please refer to the seller's policies or contact the manufacturer directly. Keep your purchase receipt as proof of purchase.
A user manual in PDF format may also be available for download from the seller's product page or manufacturer's website. (Reference: User manual (PDF))