1. Product Overview
The SONGGER PZEM-009 is a compact, embedded DC battery monitoring meter designed to provide real-time display of battery voltage and remaining capacity. It features a color LCD screen that simultaneously shows voltage, percentage capacity, and a graphical battery icon for intuitive monitoring. This device supports a wide DC voltage range (8V-100V) and is compatible with various battery chemistries, including lithium, LiFePO4, and lead-acid batteries. It is ideal for battery packs, RV power systems, solar energy storage, electric scooters, DIY battery projects, and general battery maintenance.

Figure 1: PZEM-009 DC Battery Capacity and Voltage Meter
2. Specifications
| Specification | Value |
|---|---|
| Power Supply | Self-powered from measured battery |
| Voltage Measurement Range | DC 8V – 100V |
| Voltage Accuracy | ±1% |
| Voltage Display Format | <10V: 9.99V; <100V: 99.9V; ≥100V: OL |
| Battery Capacity Display Range | 0% – 100% |
| Capacity Display Format | 9% – 100% (Integer) |
| Battery Icon Segments | 5 bars (Each = 20%) |
| Display Type | Color LCD |
| Installation Method | Embedded (Panel Cutout) |
| Waterproof Feature | Splash-proof front panel with sealing ring |
| Supported Battery Types | Lithium, LiFePO4, Lead-Acid, and similar DC battery systems |
3. Package Contents
The standard package includes:
- 1x PZEM-009 Battery Meter Unit
- 1x Set of Connection Wires
4. Safety Information and Precautions
WARNING!
- Incorrect wiring may cause device damage or battery short circuit. Always confirm correct polarity before connecting.
- Do not use the meter outside the specified DC voltage range of 8V to 100V.
- Installation should be performed by qualified personnel familiar with DC electrical systems.
- Do not expose the internal circuit to water or conductive liquids. The splash-resistant design protects only the front panel; it is not fully waterproof and must not be submerged.
- Keep out of reach of children.
- Use the meter only within the specified voltage range to avoid damage.
- Do not install the meter in environments with excessive humidity, condensation, direct water exposure, strong vibration, high temperature, or corrosive conditions.
- Disconnect power before performing installation or maintenance.
- Proper disposal must follow the Waste Electrical and Electronic Equipment Directive (WEEE) for electronic products.
5. Setup and Installation
5.1. Preparation
- Ensure the battery voltage is within the supported DC 8V to 100V range.
- Confirm correct polarity before wiring.
- If embedded installation is desired, prepare a suitable panel cutout according to the dimensions provided below.
5.2. Embedded Installation
The PZEM-009 is designed for embedded panel installation. The user needs to pre-cut an opening on the device panel.

Figure 2: Embedded Installation Method
Panel Cutout Dimensions:
- Length: 56.5 mm
- Width: 28.5 mm

Figure 3: Product Dimensions and Cutout
5.3. Wiring
The PZEM-009 features simplified wiring for easy plug-and-play installation.
- Insert the meter into the panel opening and secure it in place.
- Connect the positive (red wire) and negative (black wire) wires of the meter to the corresponding battery terminals.
- Ensure the wiring is firmly connected and insulated to prevent short circuits.

Figure 4: Simplified Wiring Diagram
6. Operating Instructions
6.1. Power On and Data Reading
After correct wiring, the display will automatically power on and begin measuring the battery voltage. The screen will show the real-time voltage value, battery percentage, and a graphical battery level indicator.

Figure 5: Display Interface
- Battery Level (Graph): Composed of 5 bars, each representing 20% of capacity.
- Battery Voltage: Numeric display of current voltage.
- Battery Level (%): Numeric display of remaining capacity percentage.
- Button: Used for display on/off and settings.
6.2. Turn Display On/Off
The LCD display can be turned on or off by short-pressing the power button on the front panel.
6.3. Full/Cutoff Voltage Setting
Before use, set the full and cutoff voltage according to your battery specifications. The default factory settings are: Full = 60.0V, Cutoff = 47.5V.
- Step 1: Long press the button to enter the full/cutoff voltage setting interface. The display will show an example like "60.0V H" (H = Full, L = Cutoff). Release the button.
- Step 2: Digits will flash from high to low. Short press the button to adjust values. The full/cutoff voltage setting interface cycles between full and cutoff settings.
- Step 3: Long press the button to save the settings and exit.
Note: The full/cutoff voltage can only be set up to 50 times. After that, further changes are not allowed.

Figure 6: Full and Cutoff Voltage Setting Interface
6.4. Voltage Calibration
The product is fully calibrated before leaving the factory. If you believe there is a deviation, manual calibration is also possible:
- Step 1: Long press the button while the power is off.
- Step 2: Input a standard DC 20V voltage.
- Step 3: The LCD will display "CAL → PASS" and return to the normal interface, indicating successful calibration. Then release the button.
7. Maintenance
- Keep the device clean and free from dust or oil contamination.
- Clean the display surface with a soft dry cloth and avoid chemical solvents.
- Store the product in a dry environment with moderate temperature when not in use for long periods.
- Avoid long-term exposure to direct sunlight or high humidity environments.
8. Troubleshooting
If the device is not functioning as expected, please check the following:
- No Display: Verify that the power connections are secure and correctly polarized. Ensure the battery voltage is within the 8V-100V operating range.
- Inaccurate Readings: Check the wiring for any loose connections. If readings are consistently off, perform a voltage calibration as described in Section 6.4.
- Display Flickering: Ensure stable power supply and check for any intermittent connections.
If issues persist, please contact customer support.
9. User Tips
- For optimal accuracy, calibrate the meter if you notice any significant deviation from known voltage sources.
- When installing in a vehicle or RV, ensure the meter is protected from direct water spray and excessive vibrations.
- Regularly check wiring connections to ensure they remain secure, especially in mobile applications.
10. Frequently Asked Questions (FAQs)
- Q1: Can this meter be used with LiFePO4 batteries?
- A1: Yes, it supports LiFePO4, lead-acid, ternary lithium, and other battery types.
- Q2: Is the display waterproof?
- A2: The front panel is splash-proof, but not suitable for submersion.
11. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the seller's official website or contact their customer service department. Keep your purchase receipt for warranty claims.

Figure 7: Contact Information
Video 1: SONGGER Company and Product Overview