1. Introduction
This EMS Physiotherapy Electric Pulse TENS Body Massager is designed for personal health care and therapy, integrating modern medical science, physics, bioelectricity, traditional Chinese medicine, and microcomputer technology. It generates non-typical cell movements and weak currents to provide various therapeutic effects, improving accuracy and efficacy.
The device features a large LCD screen for clear display of therapy modes, intensity, and time in both Chinese and English. Its unique wave composition aims to provide sensations similar to tapping, acupuncture, cupping, and massage, penetrating deep into the skin for a satisfying experience.

The TENS Body Massager in use with electrode pads.
2. Package Contents
Option 1: TENS Massager Kit
- 1 × Massager Unit
- 1 × USB Cable
- 1 × User Manual
- 2 × Connecting Cables
- 8 × Electrode Pads (4 bags, 2 pads per bag. Each pad can be reused approximately 50 times)
Option 2: Electrode Pads Only
- 20 × Electrode Pads (No massager unit included. Separate purchase is not recommended unless you already own the massager.)

The TENS massager kit components.
3. Product Overview
Familiarize yourself with the main components and controls of your TENS massager:

Main components and controls of the TENS massager.
- Electrode Socket: For connecting the electrode cables.
- LCD Screen: Displays therapy mode, intensity level, and remaining time.
- ON/OFF Button: Powers the device on or off.
- CH/EN Button: Switches the display language between Chinese and English.
- TIME Button: Adjusts the therapy duration.
- STRONG Button: Increases the intensity level.
- WEAK Button: Decreases the intensity level.
- MODE Button: Selects the therapy mode.

The high-definition LCD screen for easy viewing.
4. Setup
4.1 Battery Installation
- Open the battery compartment cover on the back of the massager.
- Insert three (3) AAA batteries (not included), ensuring correct polarity (+/-).
- Close the battery compartment cover securely.
4.2 Electrode Preparation
- Carefully peel off the smooth protective film from the adhesive side of the electrode pads.
- After use, place the electrode pads back onto their original storage sheet to preserve their adhesive quality.
4.3 Placing Electrodes
- Before applying, clean the skin area where the pads will be placed with a wet towel to remove any oil, dirt, sweat, or makeup. This ensures optimal adhesion and conductivity.
- Attach the electrode pads directly onto the target skin area.
- Connect the electrode cables to the pads and then to the massager unit's electrode sockets.
- For the treatment to be effective, both electrodes must be attached to your body. They do not need to be placed symmetrically.
Video demonstrating battery installation and electrode pad connection.
5. Operating Instructions
5.1 Power On/Off
- Press the ON/OFF button to turn the device on. The LCD screen will light up, displaying the battery status and a therapy mode selection arrow. The default mode is Acupuncture, with intensity level 0 and a time of 15 minutes.
- Press the ON/OFF button again to turn the device off.
5.2 Language Selection
- Press the CH/EN button to switch the display language on the LCD screen between Chinese and English.
5.3 Therapy Mode Selection
- Press the MODE button to cycle through the available therapy modes. The device offers 8 modes: Stroke, Massage, Acupuncture, Manipulation, Scraping, Cupping, Weight Loss, and Immunity Regulation.
- Note: If you change the therapy mode during a session, the intensity level will automatically reset to 0. Adjust the intensity as needed after selecting a new mode.

The 8 therapy modes available on the device.
5.4 Intensity Adjustment
- The device has 15 intensity levels.
- Press the STRONG button to increase the intensity by one level with each press.
- Press the WEAK button to decrease the intensity by one level with each press.

Visual representation of the 15 intensity levels.
5.5 Time Selection
- Press the TIME button to adjust the therapy duration. Each press adds 5 minutes, allowing you to set the time from 5 to 15 minutes.

Automatic timing options for therapy sessions.
6. Therapy Modes and Applications
The massager offers various modes to target different areas and conditions:

The massager can be applied to multiple body parts.
6.1 General Applications
- Body Parts: Neck, Shoulder, Back, Waist, Arm, Foot, Leg.
- Conditions: Stiff shoulders, nerve paralysis, nerve pain, shin pain, general body fatigue, stomach pain, severe cold, neck and back pain, arthritis pain, toothache, high blood pressure, low blood pressure, lack of energy, sexual weakness, irregular menstruation, and various acute and chronic diseases.
6.2 Specific Treatment Points (Acupuncture/Massage)
- Hypertension/High Blood Pressure:
- Main Point: Side of the hand crease.
- Additional Points: Area behind the fontanelle, left nape of the neck parallel to the ear, back of the shoulder base. Apply vibration acupuncture therapy for 5-6 minutes per point once daily, and 15 minutes per therapy session.
- Headache:
- Main Point: Back of the head parallel to the ear, temple area.
- Stiff Neck:
- Main Point: Ashixue (tender points).
- Additional Points: Left nape of the neck parallel to the ear, base of the shoulder. Apply strong massage on Ashixue with fingertips for a few moments. Use electrodes on acupuncture points for 10-20 minutes daily.
- Rheumatic Inflammation:
- Main Points: Front of the knee, back of the knee, area slightly above the knee.
- General Additional Healing Points: Back of the hand between the index finger and thumb, points on the back of the head, temples (with left electrode on back of head and right electrode on temple or vice versa), palm area between the index finger and thumb. Apply for 5-10 minutes per point.

Multi-site massage application.
7. Safety Warnings and Precautions
7.1 Do Not Use With:
- Cardiac pacemakers or other implanted electronic medical devices.
- Artificial heart/lung or other life-support electrical medical devices.
- Cardiac monitors or similar electrical therapy equipment.
Using this device simultaneously with the above equipment may lead to malfunction or danger.
7.2 Consult a Doctor Before Use If You Have Any of the Following Conditions:
- Malignant tumor.
- Infection.
- Menstruation or pregnancy.
- Heart disease.
- Fever above 38 degrees Celsius.
- Abnormal skin pigmentation or external skin diseases.
- Do not apply the device to hot painful areas, eyeballs, inside the mouth, or genital areas.
- Do not use this device simultaneously with other medical equipment or certain medications.
8. User Tips
- For best results, ensure your skin is clean and dry before applying the electrode pads.
- Experiment with different modes and intensity levels to find what works best for your comfort and therapeutic needs.
- If the sensation feels too strong, reduce the intensity immediately.
- Keep the electrode pads clean and store them properly on their backing to extend their lifespan.
9. Troubleshooting
9.1 No Sensation or Weak Sensation
- Ensure both electrode pads are firmly attached to the skin.
- Check that the electrode cables are securely plugged into both the pads and the massager unit.
- Increase the intensity level using the STRONG button.
- Verify that the batteries are correctly installed and not depleted. Replace if necessary.
- Clean the electrode pads and the skin area to improve conductivity.
9.2 Device Does Not Turn On
- Check battery installation and ensure batteries are fresh.
- Ensure the battery compartment cover is closed properly.
9.3 Intensity Resets to Zero Unexpectedly
- This is normal behavior if you change the therapy mode during a session. Re-adjust the intensity as desired.
10. Maintenance and Storage
10.1 Cleaning the Device
- Wipe the main unit with a soft, dry cloth. Do not use thinner, gasoline, or any other harsh cleaning agents.
- Clean dirty electrode pads with a wet cloth or by soaking them in clean water. Ensure they are completely dry before reuse or storage.
10.2 Storage
- Store the device and accessories out of reach of children.
- Keep the device away from humidity, high temperatures, direct sunlight, and water splashes.
- If the device will not be used for an extended period, remove the batteries to prevent leakage and damage.

Ensure proper care for electrode wires for longevity.
11. Specifications
| Feature | Detail |
|---|---|
| Power Supply | DC 4.5V (3 x AAA batteries, not included) |
| Frequency | 1-330 Hz |
| Power Consumption | < 180 mW |
| Battery Life | Approx. 45 hours (continuous normal operation) |
| Device Dimensions | 15.5 cm x 7 cm x 2 cm |
| Weight | 90 g |
| Application | Body |
| Voltage | <50V AC |

Device dimensions and power specifications.

Multiple power supply modes for convenience.
12. Warranty and Support
For any questions, technical support, or warranty claims, please contact the seller or manufacturer directly. Refer to your purchase documentation for specific contact information.