1. Safety Regulations

Please read the safety regulations and operation guide carefully before operating.

  • Warning: Please read all of the operational guide and safety regulations in this manual before operation. Improper operations without complying with this manual could cause damage to the device, influence on measurement results, or bodily injury to the user.
  • Warning: The instrument is not allowed to disassemble or repair in any way. It is forbidden to do any illegal modification or performance change for the laser emitter. Please keep it out of reach of children and avoid use by any irrelevant personnel.
  • Warning: It is strictly prohibited to aim the laser at eyes or other parts of the body; it is not allowed to aim the laser at any objects' surface with strong reflection.
  • Warning: Due to electromagnetic radiation interference to other equipment and devices, please do not use the meter in the plane or around medical equipment, and do not use it in inflammable, explosive environments.
  • Warning: Discarded batteries or the meter device shall not be processed like household garbage. Please handle them in line with related law and regulations.
  • Warning: Any quality issues or questions on the meter, please contact local distributors or the manufacturer in time.

2. Product Overview

2.1 Display and Keyboard Layout

The device features a clear LCD display and intuitive button layout for various functions.

SNDWAY Laser Distance Meter Display and Keyboard Layout

Image: Detailed view of the laser distance meter's display and keyboard, showing icons for various functions like distance, area, volume, Pythagorean, angle/height, and painter function.

Display Elements:

  • Power Supply: Battery indicator.
  • Record: Indicates stored measurements.
  • Length, Area, Volume and Pythagorean: Icons for selected measurement mode.
  • Laser on: Laser activation indicator.
  • Maximum: Displays maximum measured value in continuous mode.
  • Auxiliary Display: Shows previous measurement or intermediate values.
  • Minimum: Displays minimum measured value in continuous mode.
  • Major Display: Shows current or final measurement result.

Keyboard Functions:

  • READ: Turn on/Measuring.
  • +: Addition.
  • - / ♪: Subtraction / Sound.
  • □ / △ / ▧: Area / Volume / Pythagorean Measuring.
  • ≡: Save.
  • ⌂ / U: Reference Point / Unit Switch.
  • OFF CLEAR: Turn off / Remove.

3. Setup

3.1 Battery Installation and Replacement

The device uses 1.5V AAA alkaline batteries (not included).

Battery Installation Diagram

Image: Diagram showing how to open the battery compartment and insert AAA batteries with correct polarity.

  1. Discharge the battery door on the back of the device.
  2. Place batteries according to the correct polarity (+/-).
  3. Cover the battery door.
  4. If not used for a long time, please take out the batteries to avoid corrosion to the meter body.

3.2 Starting the Instrument

  1. Under off status, press the READ button. The device and laser will start simultaneously and stand by for measurement.
  2. To turn off the device: Under on status, long press the OFF CLEAR button for 3 seconds. The device will also shut off automatically if there is no operation for 150 seconds.

3.3 Unit Setting

Long press the ⌂ U button to reset the current measurement unit. The default unit is 0.000m. There are 6 units for selection:

Units:LengthAreaVolume
Metric0.000m0.000m²0.000m³
Metric (2 decimal)0.00m0.00m²0.00m³
Imperial (inches)0.0in0.00ft²0.00ft³
Imperial (feet)0.00ft0.00ft²0.00ft³
Imperial (feet/inches)0 1/16 in0.00ft²0.00ft³
Imperial (feet/inches fractional)0'00''1/160.00ft²0.00ft³

3.4 Changing Reference Point

Press the ⌂ U key to change the reference point. The device reference point by default is the rear.

3.5 Backlight On/Off

The backlight is set to turn on and off automatically. The backlight can be on for 15 seconds while operating, and it will shut off automatically in 15 seconds when there is no operation to the device.

3.6 Sound On/Off

Long press the ♪ button to turn on or off the buzzer.

3.7 Self-Calibration

This function helps maintain the precision of the device.

  1. Power off the device.
  2. Long press the OFF CLEAR button and then press READ.
  3. Release the READ button.