Toviyon TPA Series

Contents

Toviyon DC Laboratory Power Supply

Instruction Manual

Model: TPA Series

1. Safety Summary

Welcome to our DC regulated power supply. This manual contains essential safety instructions that must be followed for the operation, use, and storage environment of this product series. To ensure your personal safety, please thoroughly read this manual before operation to avoid personal injury due to improper handling or damage to the power supply and other connected load equipment.

Safety Symbols

The following safety symbols may appear in the manual or on the machine:

  • ⚠

    Warning Label

  • ⚡

    High Volt Danger

  • ⏚

    Grounding

  • CE

    Certification Mark

  • 🗑️

    Do Not Litter

  • 🏠

    Indoor Use

2. Product Overview

The TPA series is a digital display programmable switching DC regulated power supply that can simultaneously display voltage, current, and power. This power supply is widely used in product aging, battery charging, R&D testing, schools, and production lines. Its output voltage and current are both adjustable via an encode knob, continuously adjustable between 0 and the nominal value.

The power supply has excellent stability and ripple coefficient, and features multiple protection circuits including short-circuit protection, overvoltage protection, overcurrent protection, and overtemperature protection. The product boasts an attractive design, user-friendly operation, and the ability to work at full capacity for extended periods. It is equipped with a USB fast charging interface and offers optional PC software control functionality, making it a popular choice among users.

Video: Toviyon DC Power Supply Product Demonstration

3. Setup

3.1 AC Input

Please verify the AC voltage input permitted for this machine. The power supply supports either 230V ±10% 50Hz or 115V +10% 60Hz. Refer to the label information located near the power outlet on the back of the machine for the specific input voltage.

⚠ WARNING: Incorrect AC voltage input will cause serious damage to the machine. Please ensure that the machine requires the correct input voltage.

3.2 Connect the Ground Wire

When using this product, please ensure the power cord is properly grounded. If the power outlet does not have a ground wire, you can use a wire to connect the machine's grounding terminal to the earth. Proper grounding can effectively prevent machine leakage and reduce output ripple interference.

3.3 Connect the Load Device

  1. Securely connect the output wires to the power supply terminals according to the positive (+) and negative (-) markings.
  2. Securely connect the other end of the output lead to the positive and negative terminals of your load device.
⚠ CAUTION: Incorrect connections may damage the power supply and the load connected to it. When connecting loads such as batteries, do not reverse the "+" and "-" terminals, as this may damage the power supply.

4. Operating Instructions

4.1 Front Panel Introduction

The front panel of your Toviyon DC Power Supply features various controls and displays for precise operation.

Front panel of Toviyon DC Power Supply showing display, knobs, and ports.

Image: Front Panel Layout

  1. Voltage Display: Shows the output voltage.
  2. Current Display: Shows the output current.
  3. Power Display: Shows the output power.
  4. C.V (Constant Voltage Indicator Light): Illuminates when the power supply is operating in Constant Voltage mode.
  5. M1-M4 Storage Indicator Light: Indicates which memory preset (M1 to M4) is currently selected or being set.
  6. C.C (Constant Current Indicator Light): Illuminates when the power supply is operating in Constant Current mode.
  7. OPN Indicator Light: Indicates the status of the OPN function (Output Power On/Off at startup).
  8. Current Adjustment Knob: Used to set the output current.
  9. Voltage Adjustment Knob: Used to set the output voltage.
  10. Button Lock Switch: Locks other buttons and knobs to prevent accidental changes.
  11. Storage Selection/Storage Value Setting Switch (MEMORY): Used to select and save voltage/current presets.
  12. Short-Circuit/Overcurrent Protection Switch (OCP): Activates or deactivates overcurrent protection.
  13. Over Voltage Protection Switch (OVP): Activates or deactivates overvoltage protection.
  14. Buzzer Switch: Toggles the audible alarm on or off.
  15. Output Switch: Turns the power output on or off.
  16. USB-A Fast Charging Port: Provides fast charging via USB-A.
  17. USB-C Fast Charging Port: Provides fast charging via USB-C.
  18. Power Switch: Turns the entire unit on or off.
  19. Negative Output Port (Black): Connects to the negative terminal of the load.
  20. Ground Terminal (Green): For connecting to earth ground.
  21. Positive Output Port (Red): Connects to the positive terminal of the load.

4.2 Constant Voltage (CV) and Constant Current (CC) Mode

The power supply operates in two primary modes: Constant Voltage (CV) and Constant Current (CC). The mode is automatically determined by the voltage and current values you set and the load connected. The output voltage or current will not exceed your set limits.

  • Constant Voltage (CV) Mode: The output voltage remains equal to your set voltage value, while the current varies according to the load, up to your set current limit.
  • Constant Current (CC) Mode: The output current remains equal to your set current value, while the voltage varies according to the load, up to your set voltage limit.
Note: During CV operation, if the load resistance decreases causing the output current to reach the set current value, the power supply will automatically switch to CC mode. The current will remain at the set value while voltage decreases. Increasing load resistance or raising the current set value will restore CV mode.

4.3 Voltage Adjustment Knob

Rotate clockwise to increase the voltage; rotate counter-clockwise to decrease. Press the knob to move the cursor to adjust individual digits. The setting is saved automatically after 3 seconds of inactivity.

High-precision encoder adjustment knob for voltage and current.

Image: High-Precision Encoder Adjustment Knob

4.4 Current Adjustment Knob

Rotate clockwise to increase the current; rotate counter-clockwise to decrease. Press the knob to move the cursor to adjust individual digits. The setting is saved automatically after 3 seconds of inactivity.

4.5 Lock Button Switch

Press the LOCK button to disable all operations (except the Power switch and the LOCK button itself) to prevent accidental changes during work. Press LOCK again to resume operations.

One-click output locking feature to prevent accidental operations.

Image: One-Click Output Locking

4.6 Memory Storage (M1-M4)

The unit has four memory presets (M1-M4) to store and recall frequently used voltage/current settings.

  • Selecting a Preset: Press the MEMORY button to cycle through M1, M2, M3, and M4. The selected preset will be indicated on the display.
  • Setting a Preset: Select the desired memory slot (e.g., M2). Press and hold the MEMORY button for 3 seconds (you will hear two beeps) to enter parameter setting mode. Use the Voltage/Current knobs to adjust values. Press and hold MEMORY for 3 seconds within 8 seconds to save (two beeps). If not saved within 8 seconds, the interface will exit without saving.
Four groups memory storage function with examples of stored values.

Image: 4 Groups Memory Storage Function

4.7 OCP (Short-Circuit/Overcurrent Protection)

Press the OCP button to enable/disable this protection. When enabled, the indicator light illuminates. If a short circuit or overcurrent occurs, the unit stops output and alarms. Press OUTPUT or OCP to deactivate the alarm and shut off power. Note: OCP cannot be used in Constant Current (CC) mode.

4.8 OVP (Over Voltage Protection)

Press the OVP button to enable/disable this protection. When enabled, the indicator light illuminates. If an overvoltage occurs, the unit stops output and alarms. Press OUTPUT or OVP to deactivate the alarm and shut off power.

Excellent safety performance with OCP and OVP features.

Image: Excellent Safety Performance (OCP & OVP)

4.9 Buzzer Switch

Press the buzzer button to toggle the audible alarm on or off.

4.10 Output Switch

Press the OUTPUT button to turn the power output on or off.

4.11 OPN Function

The OPN function controls whether the OUTPUT is ON or OFF each time the device is powered on.

  • To Enable/Disable: With the OUTPUT button OFF, press and hold the OUTPUT button for 3 seconds (two beeps). Use the OUTPUT button or Voltage/Current knob to select ON or OFF. Press and hold OUTPUT for 3 seconds to save and exit (two beeps).

4.12 USB Fast Charging Function

This device features USB-A and USB-C fast charging ports with a built-in multi-protocol fast charging identification chip, providing a maximum output power of 18W.

Multi-functional device with dual fast charge groups (USB-A, USB-C, QC3.0).

Image: Multi-functional Device, Dual Fast Charge Groups

4.13 Host Computer Communication (Optional)

Users can choose models equipped with USB / RS-232 / RS485 communication modules to communicate with a host computer via the MODBUS protocol, enabling remote control.

5. Maintenance

5.1 Regular Inspection, Cleaning, and Maintenance

Regular maintenance helps extend the lifespan of your power supply. Follow these steps:

  1. Turn off the power switch and unplug the power cord from the socket.
  2. Gently wipe the casing, top cover, and vents with a soft cloth and mild detergent.
  3. Visually inspect all power cords and terminals for damage such as impact, loosening, heat corrosion, moisture, or insect bites. Replace any damaged power cords or terminals with those of the same specifications and dimensions.

5.2 Replace Fuse

If the fuse blows, the machine will stop working. Find and correct the cause of the blown fuse before replacing it with a fuse of the same specifications.

  • First, unplug the power cord.
  • Open the fuse holder (located near the power outlet on the back).
  • Replace the blown fuse with a new one of the same model and specifications.
  • Reinsert the fuse holder.
⚠ WARNING: For effective safety protection, only fuses of specific specifications should be replaced. Do not unplug the power cord before replacing the fuse.

6. Troubleshooting

This section provides basic troubleshooting steps for common issues. For more complex problems, please contact support.

  • No Power/Display:
    • Check if the power cord is securely connected to both the unit and the AC outlet.
    • Ensure the power switch on the unit is in the 'ON' position.
    • Check the fuse (refer to 'Replace Fuse' section).
  • No Output Voltage/Current:
    • Ensure the OUTPUT switch is turned 'ON'.
    • Verify that OCP or OVP protection has not been triggered (check indicator lights). If triggered, clear the fault and reset.
    • Check load connections for any short circuits or open circuits.
    • Ensure voltage and current limits are set above zero.
  • Unstable Output:
    • Check for loose connections at the power supply terminals or the load.
    • Ensure the load is within the power supply's specifications.

7. Specifications

Machine Parameter Table

ParameterTPA305TPA3010TPA605TPA1203TPA1602
Output Volt0-30V0-30V0-60V0-120V0-160V
Output Current0-5A0-10A0-5A0-3A0-2A
Output Power0-150W0-300W0-300W0-360W0-320W
Fuse3.15A5A5A5A5A
AccessibilityDual fast charging ports, short circuit protection, four storage groups, lock function, buzzer, one-button output.
C.V. (Constant voltage state)Voltage Stability: ≤0.5% + 3mV
Load Stability: ≤0.5% + 3mV
Ripple: ≤0.5% Vp-p
C.C. (Constant current state)Current Stability: ≤0.5% + 3mA
Load Stability: ≤0.5% + 3mA
Ripple: ≤0.5% Ap-p
Product DimensionsLength 214mm, Width 90mm, Height 156mm
Product WeightNet weight: 1.17 kg. Gross weight: 1.55 kg.
Operating Temp0°C - 40°C, Relative humidity: <80%RH
Storage Temp-10°C - 50°C, Relative humidity: <70%RH
Protection MethodOvervoltage Protection, Overcurrent Protection, Overtemperature Protection, Short Circuit Protection
Display Accuracy0.5% + 3 words
Maximum ResolutionVolt: 0.001V; Current: 0.001A

Note: The above parameters were measured at an ambient temperature of 25±5°C, relative humidity <80%RH, and after preheating for 30 minutes. Actual parameters may vary slightly.

8. Warranty and Support

8.1 Product Inspection

Each product comes with an instruction manual and a certificate of conformity to ensure proper usage. All products are manufactured and inspected according to manufacturer's standards; any unqualified products will not leave the factory.

8.2 Product Warranty

A one-year warranty is provided, excluding damage caused by human error.

8.3 Product Repair

  • Free repair or replacement of parts is provided during the warranty period. After the warranty period, paid repair services are available.
  • During the product's service life, if the product malfunctions, the company is only responsible for the malfunction and loss of the product itself; the company does not bear any load or other related losses.

Guarantee Limitations:

The warranty does not apply to losses caused by the following circumstances:

  1. Customer violation of the usage instructions in this manual.
  2. Customer disassembly or repair of the product.
  3. Unauthorized modifications or misuse.
  4. Operation of the product outside the specified environment.
  5. Force majeure factors under relevant laws.

8.4 Contact Information

For further assistance or inquiries, please contact:

Shenzhen Toviyon Electronics Technology Co., Ltd.
Address: Room 203, 2nd Floor, No. 69, Langkou Industrial Park, Langkou Community, Dalang Subdistrict, Longhua District, Shenzhen
Web: www.toviyon.com
Tel: (+86)18588483965
WhatsApp: +1(424)413-3536
WeChat: 18588483965

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.