1. Safety Summary
Welcome to your NANKADF DC stabilized power supply. This manual contains important safety instructions for product operation and storage. For your personal safety, please read this manual thoroughly before operation to prevent injury or damage to the power supply and connected loads due to improper use.
1.1 Safety Symbols
The following safety symbols may appear in this manual or on the machine:
- ⚠ Warning: Indicates potential hazards that could result in injury or damage.
- ⚡ High Voltage Hazard: Indicates the presence of dangerous voltage levels.
- 🔍 Grounding Wire: Indicates a required grounding connection.
- ✘ Do Not Litter: Indicates proper disposal requirements.
- 🏠 Indoor Use: Indicates the product is intended for indoor use only.
- CE Accreditation: Indicates compliance with European safety standards.
2. Setup
2.1 AC Input Voltage Selection
Before connecting the power supply, determine the permissible AC input voltage. This machine supports two types of AC voltage input: AC 230V±10% or AC 115V±10%. Use the changeover switch located on the rear panel to select the appropriate voltage.
- If "230V" is visible on the switch, the allowable input voltage is AC 230V±10%.
- If "115V" is visible on the switch, the allowable input voltage is AC 115V±10%.
⚠ Warning: Incorrect AC voltage input can cause serious damage to the machine. Always verify the required input voltage value.

2.2 Grounding
Ensure the power cord is properly grounded when using this product. If your power outlet lacks a ground wire, connect the machine's ground terminal to earth using a separate wire. Proper grounding effectively prevents electrical leakage and reduces output ripple interference.
🔍 Good grounding prevents leakage and reduces output ripple.
2.3 Unboxing and Product List
Upon unboxing, verify that all components are present:
- 1x DC Power Supply
- 1x Input Power Cord
- 1x Output Power Cord (Test Lead)
- 1x Operation Manual

3. Operating Instructions
3.1 Panel Description (TPS Series)
Refer to the diagram below for the layout and function of the TPS Series front and rear panels.

| No. | Component | Description |
|---|---|---|
| 1 | Voltage output display | Shows the current output voltage. |
| 2 | Type-C fast charging | Type-C fast charging port. |
| 3 | Current output display | Shows the current output current. |
| 4 | USB-A fast charging | USB-A fast charging port. |
| 5 | Power display | Shows the current output power. |
| 6 | CV indicator | Lights up when in Constant Voltage mode. |
| 7 | CC indicator | Lights up when in Constant Current mode. |
| 8 | Output indicator | Lights up when output is active. |
| 9 | OCP indicator | Lights up when Over Current Protection is active. |
| 10 | Output switch | Toggles power output on/off. |
| 11 | V/A Toggle Adjustment Key | Switches between voltage and current adjustment modes. |
| 12 | OCP switch | Enables/disables Over Current Protection. |
| 13 | Voltage/current setting knob | Adjusts voltage/current. Long press to toggle buzzer. |
| 14 | Power switch | Turns the main power of the unit on/off. |
| 15 | Positive polarity (Red) | Positive output terminal. |
| 16 | Grounding terminal (Green) | Ground connection terminal. |
| 17 | Negative polarity (Black) | Negative output terminal. |
3.2 Panel Description (TPS-C Series)
Refer to the diagram below for the layout and function of the TPS-C Series front and rear panels.

| No. | Component | Description |
|---|---|---|
| 1 | Voltage output display | Shows the current output voltage. |
| 2 | CV indicator | Lights up when in Constant Voltage mode. |
| 3 | Current output display | Shows the current output current. |
| 4 | CC indicator | Lights up when in Constant Current mode. |
| 5 | Power display | Shows the current output power. |
| 6 | USB-A fast charging | USB-A fast charging port. |
| 7 | USB voltage display | Shows the USB output voltage. |
| 8 | USB current display | Shows the USB output current. |
| 9 | Memory Switch (M1, M2, M3) | Stores and recalls voltage/current settings. |
| 10 | Pushbutton Lock Switch | Locks/unlocks panel keys. |
| 11 | OCP Switch | Enables/disables Over Current Protection. |
| 12 | Output switch | Toggles power output on/off. |
| 13 | Voltage setting knob | Adjusts voltage. Long press to toggle buzzer. |
| 14 | Current setting knob | Adjusts current. |
| 15 | Positive polarity (Red) | Positive output terminal. |
| 16 | Negative polarity (Black) | Negative output terminal. |
| 17 | Power switch | Turns the main power of the unit on/off. |
3.3 Rear Panel Description (TPS/TPS-C Series)
| No. | Component | Description |
|---|---|---|
| 18 | Cooling Fan | Activates when internal temperature exceeds 50°C. |
| 19 | Electric socket | AC power input socket. |
| 20 | Fuse box | Contains the protective fuse. |
| 21 | AC Selector Switch | Selects between 115V and 230V AC input. |
3.4 Constant Voltage (CV) / Constant Current (CC) Mode
The power supply operates in two main output modes: Constant Voltage (C.V) and Constant Current (C.C). The active mode is determined by the user-set voltage and current values, and the connected load. The output voltage or current will not exceed the values set by the user.
- In C.V. mode, the output voltage equals the user-set voltage.
- In C.C. mode, the output current equals the user-set current.
⚠ Notice: In actual C.V. operation, if the load resistance decreases, causing the output current to rise to the set current value, the power supply will automatically switch to C.C. mode. If the load resistance continues to decrease, the current will remain at the set value, and the voltage will decrease proportionally (I=V/R). To restore C.V. output, increase the load resistance or increase the set current value.
3.5 Voltage/Current Regulation
To adjust the output voltage and current:
- Press the voltage/current switching button (V/A Toggle Adjustment Key on TPS, or the respective knob on TPS-C) to switch between current and voltage setting. The corresponding display LED will flash.
- Rotate the adjustment knob (Voltage/Current setting knob on TPS, or Voltage/Current setting knob on TPS-C) to the desired value.
- When adjusting, press the knob to jump between digit positions for easier numerical adjustment.

3.6 Output Switch (OUT)
Pressing the "OUT" button toggles the power supply output on or off. The output indicator will light up when the output is active.

3.7 Over Current Protection (OCP) Switch
Press the "OCP" button to enable or disable the OCP function. When enabled, the OCP indicator light will be on. If a short circuit or overcurrent occurs, the machine will stop output and trigger an alarm. Press the "OUT" button to clear the alarm and turn off the output.
Note: The machine determines a short circuit based on whether the output current exceeds the user-set current. Therefore, OCP cannot be used in Constant Current (C.C.) mode.
3.8 Fast Charging Function (USB-A/Type-C)
This power supply features USB-A and Type-C fast charging ports with a built-in multi-protocol fast charging recognition chip, providing up to 18W output power. The screen can display the current output voltage and current values for the USB ports.

3.9 Buzzer On/Off
Long press the voltage adjustment knob (item 13 on TPS, item 13 on TPS-C) for 3 seconds to turn the buzzer sound on or off.
3.10 Data Memory Storage (TPS-C Series Only)
The TPS-C series features three sets of memory functions (M1, M2, M3) for storing and recalling common parameters.
- To save: Long press any M1-M3 button until you hear a buzzer sound. The current set voltage and current values will be stored.
- To recall: Short press the corresponding M1-M3 button to access the previously stored data.

3.11 Key Lock Switch (TPS-C Series Only)
Press the pushbutton lock switch (item 10 on TPS-C) to lock all panel keys. The keypad light will illuminate, indicating that the function keys are locked and cannot be used. Press the switch again to unlock the keys; the keypad light will turn off, and the function keys will be active.
4. Maintenance
4.1 Regular Inspection and Cleaning
Regular inspection, cleaning, and maintenance help extend the life of your power supply. Follow these steps:
- Turn off the power switch and unplug the power cord from the outlet.
- Lightly wipe the case, top cover, and vents with a soft cloth and mild detergent.
- Visually inspect all power cords and terminals for collision, looseness, heat erosion, moisture, or insect damage. Replace any damaged cords or terminals with ones of the same size promptly.

4.2 Fuse Replacement
If the fuse blows, the machine will stop operating. Identify the cause of the blown fuse and replace it with a fuse of the same specifications.
5. Troubleshooting
This section addresses common issues you might encounter with your power supply.
No Power / Unit Not Turning On:
- Check if the power cord is securely connected to both the unit and the power outlet.
- Verify the AC input voltage selector switch on the rear panel is set correctly (115V or 230V) for your region.
- Inspect the fuse in the fuse box on the rear panel. If blown, replace it with a fuse of the same rating (refer to Section 4.2).
Output Stops / Alarm Sounds:
- This indicates that the Over Current Protection (OCP) has been triggered.
- Check the connected load for a short circuit or excessive current draw.
- Press the "OUT" button to clear the alarm and reset the output.
Inaccurate Voltage/Current Readings:
- Ensure proper connection of test leads to the output terminals.
- Verify that the unit is not operating in Constant Current (CC) mode if you expect Constant Voltage (CV) behavior, or vice-versa.
- For high-precision applications, use an external calibrated multimeter to verify readings.
6. Specifications
The following tables detail the specifications for the TPS and TPS-C series models.
6.1 TPS Series Specifications
| Parameter | TPS305 | TPS3010 | TPS605 | TPS1203 | TPS1602 |
|---|---|---|---|---|---|
| Output Voltage | 0~30V | 0~30V | 0~60V | 0~120V | 0~160V |
| Output Current | 0~5A | 0~10A | 0~5A | 0~3A | 0~2A |
| Output Power | 150W | 300W | 300W | 360W | 320W |
| Fuse Specifications | 3A | 5A | 5A | 5A | 5A |
6.2 TPS-C Series Specifications
| Parameter | TPS-C305 | TPS-C3010 | TPS-C605 | TPS-C1203 | TPS-C1602 |
|---|---|---|---|---|---|
| Output Voltage | 0~30V | 0~30V | 0~60V | 0~120V | 0~160V |
| Output Current | 0~5A | 0~10A | 0~5A | 0~3A | 0~2A |
| Output Power | 150W | 300W | 300W | 360W | 320W |
| Fuse Specifications | 3A | 5A | 5A | 5A | 5A |
6.3 General Specifications
- Product Size: L210mm x W145mm x H80mm
- Net Weight: 1.15Kg
- Gross Weight: 1.5Kg

7. Warranty and Support
7.1 Warranty Period
This product comes with a twelve-month warranty against non-artificial damage from the date of purchase.
7.2 Maintenance Services
- During the warranty period, free repair or replacement parts will be provided for product malfunctions.
- Beyond the warranty period, chargeable repair services are available.
- The manufacturer is responsible only for the malfunction and loss of this product during the maintenance period, and not for any consequential damages to connected loads or other equipment.
7.3 Warranty Limitations
The warranty does not cover damages caused by:
- Violation of the terms of use outlined in this manual.
- Disassembly or repair of the product by the customer.
- Unauthorized modification or misuse.
- Operation of the product outside its specified environment.
- Irresistible factors as per relevant laws.
7.4 Additional Resources
For a detailed user manual in PDF format, please refer to the official document: User Manual (PDF).