SONGGER MH-01, MH-02

Contents

SONGGER MH-01 / MH-02 Multi-Function Water Flow Sensor User Manual

Model: MH-01, MH-02

1. Introduction

The SONGGER MH-01 and MH-02 series are compact multi-parameter water monitoring sensors designed for integrating flow measurement, TDS detection, and optional temperature sensing. Utilizing Hall-effect pulse output technology, these sensors provide stable and accurate real-time monitoring for low-flow water systems.

These products are ideal for RO filtration systems, smart water appliances, laboratory fluid control, and IoT-based water quality monitoring applications.

2. Product Overview

The MH-01 and MH-02 sensors offer versatile functionality to meet various water monitoring needs:

  • MH-01 (2-in-1): Monitors flow and TDS. Available with micro (1mm, 0.1–1L/min) or large bore (4mm, 0.3–3L/min) sizes. Can be configured with integrated or split cable designs. Temperature detection is not included by default but can be customized.
  • MH-01 (3-in-1): Monitors flow, TDS, and temperature. Features a 6-wire integrated cable only. Bore size is 4mm.
  • MH-02 (3-in-1): Monitors flow, TDS, and temperature. Features an integrated cable only. Bore size is 9.5mm.

All models operate on DC 5–18V (MH-02 optional DC 7-24V) and provide a flow detection accuracy of ±3%.

SONGGER MH01 3-IN-1 Water Flow Sensor with key specifications
Figure 1: MH01 3-IN-1 Water Flow Sensor Overview

3. Safety Information

3.1. Precautions

  • Use only within the specified voltage and pressure range.
  • Do not exceed 0.8 MPa system pressure.
  • Do not operate above 80°C liquid temperature.
  • Prevent freezing or condensation inside the sensor.
  • Ensure liquid is free of large particles or debris to avoid rotor blockage.
  • Disconnect power before installation or maintenance.
  • Do not pull or twist the signal cable excessively.
  • Keep away from strong electromagnetic interference sources.

3.2. Warning Information (EU Market Reference)

WARNING!

  • This device operates with electrical power. Incorrect wiring may cause short circuit or equipment damage.
  • Do not use in systems exceeding the rated pressure limit. Risk of leakage or rupture.
  • Installation must be performed by qualified personnel in accordance with applicable electrical and plumbing standards.
  • This product is not a safety shut-off device. Do not rely on it as the sole protection mechanism.
  • Keep out of reach of children.
  • Proper disposal: Follow WEEE Directive 2012/19/EU for electronic waste disposal.

Note: The above warning information is for reference only. Final warning language must comply with the official language requirements of the destination EU country.

4. Package Contents

Upon unpacking, please ensure all items are present:

  • Flow sensor unit (MH-01 or MH-02, according to selected model)
  • Connection cable (integrated or split, according to selected model)

5. Setup

5.1. Preparation

  1. Ensure the selected model matches the pipe diameter and required flow range for your application.
  2. Confirm that your power supply voltage is within the specified operating range for the sensor.
  3. Install the sensor in the correct flow direction as indicated by an arrow or marking on the sensor housing.

5.2. Installation

  1. Connect the inlet and outlet ports of the sensor to compatible PE tubing (6.35mm for MH-01, 9.5mm for MH-02).
  2. Ensure all fittings are securely sealed and leak-free to prevent water leakage.
  3. Connect the signal wires according to the wiring definitions provided below. Avoid applying mechanical stress to the cable during connection.

5.3. Wiring Diagrams

Refer to the following diagrams for proper wiring connections based on your sensor model:

MH-01 (3-in-1, 6-Wire Integrated)

MH-01 3-in-1 Wiring Diagram
Figure 2: MH-01 (3-in-1) Wiring - Red, Black, Yellow (Flow Rate); Green (Water Temperature); Red, Blue (TDS)
MH-01 Six-Wire Pinout
Figure 3: MH-01 Six-Wire Pinout - Red: Positive (+), Black: Negative (-), Yellow: Pulse Signal, Green: Temperature Output, Red/Blue: TDS

MH-01 (2-in-1, Flow + TDS)

MH-01 2-in-1 Wiring Diagram
Figure 4: MH-01 (2-in-1) Wiring - Red, Black, Yellow (Flow Rate); Red, Blue (TDS)

MH-02 (3-in-1, 6-Wire Integrated)

MH-02 3-in-1 Wiring Diagram
Figure 5: MH-02 (3-in-1) Wiring - Red, Black, Yellow (Flow Rate); Blue, Brown (TDS)

5.4. Dimensional Drawings

MH-01 Dimensions

MH-01 Dimensional Drawing
Figure 6: MH-01 Dimensional Drawing

MH-02 Dimensions

MH-02 Dimensional Drawing
Figure 7: MH-02 Dimensional Drawing

6. Operation

6.1. Power On

After confirming secure installation and wiring, power on your system. The sensor will begin to operate.

6.2. Data Output

  • Flow Rate: The sensor outputs a pulse signal proportional to the flow rate.
  • TDS & Temperature (3-in-1 models): For 3-in-1 models, TDS and temperature signals are available through the integrated cable.

6.3. Data Reading

Use a compatible controller or microcontroller to calculate the flow rate based on the pulse frequency formula provided in the specifications. Convert the frequency to flow rate using the specified equation. Apply calibration in your host system if required for optimal accuracy.

7. Maintenance

7.1. Storage

  • Store the sensor in a dry, ventilated environment within the specified storage temperature range (-25°C to +80°C).
  • Avoid direct sunlight and corrosive atmospheres.

7.2. Cleaning

  • Flush with clean water before long-term storage if the sensor has been used with treated or mineralized water.
  • Periodically inspect the sensor for scaling or debris buildup.
  • Do not use aggressive solvents for cleaning, as this may damage the sensor materials.

8. Troubleshooting

8.1. No Flow Reading / Inaccurate Reading

  • Check Power: Ensure the sensor is receiving power within its specified voltage range (DC 5-18V).
  • Check Wiring: Verify all wires are correctly connected according to the wiring diagrams. Loose or incorrect connections can prevent data output.
  • Check Flow Direction: Ensure the sensor is installed in the correct direction of water flow.
  • Check for Blockages: Inspect the sensor's internal rotor for any debris or particles that might be obstructing its movement.
  • System Pressure: Confirm that the system pressure is within the sensor's operating limits (≤0.8 MPa).
  • Liquid Temperature: Ensure the liquid temperature does not exceed 80°C.

8.2. Leakage

  • Check Connections: Ensure all pipe connections to the sensor's inlet and outlet are tight and properly sealed.
  • Inspect Tubing: Verify that the PE tubing is compatible with the sensor's interface and free from cracks or damage.

8.3. No TDS / Temperature Reading (3-in-1 models)

  • Check Wiring: Ensure the specific wires for TDS (Red/Blue or Blue/Brown) and Temperature (Green) are correctly connected to your monitoring system.
  • Sensor Functionality: Confirm you are using a 3-in-1 model that supports these functions.

9. Specifications

9.1. General Specifications

ParameterMH-01 (2-in-1)MH-01 (3-in-1, 6-wire)MH-02 (3-in-1)
FunctionFlow + TDSFlow + TDS + TemperatureFlow + TDS + Temperature
Cable TypeIntegrated / Split6-wire Integrated OnlyIntegrated Only
Bore Size4mm / 1mm4mm9.5mm
Pipe Interface6.35mm PE pipe6.35mm PE pipe9.5mm PE pipe
Operating VoltageDC 5~18VDC 5~18VDC 5~18V / 7~24V
Minimum Rated VoltageDC 3.5VDC 3.5VDC 3.5V
Max Working Current15mA (DC 5V)15mA (DC 5V)155mA (DC 5V)
Load Capacity≤10mA≤10mA≤10mA
Temperature DetectionNo (customizable)YesYes
Operating Temperature Range≤80°C≤80°C≤80°C
Operating Humidity35%–90% RH (no frost)35%–90% RH (no frost)35%–90% RH (no frost)
Storage Temperature-25~+80°C-25~+80°C-25~+80°C
Storage Humidity25%–95% RH25%–95% RH25%–95% RH
Max Pressure≤0.8MPa≤0.8MPa≤0.8MPa
Flow Detection Accuracy0.1~3L/min ±3%0.3~6L/min ±3%0.5~6L/min ±3%
Flow Range DetailsLarge bore: 0.3–3L/min
Small bore: 0.1–1L/min
0.3–6L/min0.5–6L/min
Pulse Output Duty Cycle50 ±10%50 ±10%50 ±10%
Output Rise Time0.04μs0.04μs0.04μs
Output Fall Time0.18μs0.18μs0.18μs
Pulse Frequency FormulaHz = 36 × Q + 3% (Q=L/min)Hz = 36 × Q + 3% (Q=L/min)Hz = 15 × Q - 2 + 3% (Q=L/min)

9.2. Temperature Probe Characteristics (for 3-in-1 models)

50k, 3950 Temperature Probe Table
Figure 8: 50k, 3950 Temperature Probe Table (Temperature vs. Resistance)

10. User Tips

  • Easy Integration: The sensor often arrives with wiring labeled and connectors pre-stripped, making integration into controller boards straightforward.
  • Stable Output: The pulse output is generally stable and easy to interface with microcontrollers for real-time monitoring.
  • Versatile Use: Suitable for various low-flow systems, including water dispensers and purification setups.
  • Compact Design: Its compact build allows it to fit into small piping configurations.

11. Warranty & Support

11.1. Compliance Disclaimer

This document is provided for product instruction purposes only. It does not constitute legal advice. The seller is responsible for ensuring compliance with destination market regulations.

11.2. Technical Support

For bulk orders or technical consultations, please feel free to contact us:

Contact Us Information