meterk JS-020ISG-S-3L-J4

Contents

4-20mA Current Voltage Signal Generator

Model: JS-020ISG-S-3L-J4 | Brand: Meterek

1. Introduction

This manual provides detailed instructions for the safe and effective use of your 4-20mA Current Voltage Signal Generator. This multifunctional device is designed to generate both ampere and voltage signals, making it an essential tool for various industrial and testing applications. Please read this manual thoroughly before operation and retain it for future reference.

Front view of the 4-20mA Current Voltage Signal Generator with a rotary knob and a 4-digit LED display.
Figure 1: Front view of the Signal Generator, showing the rotary knob and LED display.

2. Safety Information

WARNING: To avoid danger of suffocation, keep any plastic packaging material away from babies and children.

  • Ensure proper power supply voltage (Vp=DC24V (15-28V)) as indicated on the device.
  • Do not attempt to disassemble or modify the device, as this may void the warranty and pose safety risks.
  • Operate the device in a dry environment, away from moisture and extreme temperatures.
  • The device features reverse polarity protection for the power supply and short-circuit protection for the output. However, always double-check connections before powering on.

3. Setup and Connections

The signal generator is designed for direct installation and use. Follow these steps for proper connection:

  1. Identify Terminals: Locate the terminal block on the back of the module. The terminals are labeled G, V+, OUT, and G.
  2. Power Supply Connection: Connect your DC24V (15-28V) power supply to the V+ (positive) and G (ground) terminals. Ensure correct polarity.
  3. Output Connection: Connect the device requiring the signal to the OUT (signal output) and G (ground) terminals.
Back view of the signal generator showing the green terminal block with labels G, V+, OUT, G, and the model number JS-020ISG-S-3L-J4.
Figure 2: Back view with terminal block and wiring labels.

Wiring Details:

  • G: Power Ground / Signal Ground
  • V+: Power Input (DC24V, range 15-28V)
  • OUT: Signal Output (4-20mA)

4. Operating Instructions

The signal generator provides both ampere and voltage dual signals with a clear 4-digit LED display.

  1. Power On: Once connected to a suitable power supply, the LED display will illuminate.
  2. Signal Generation: Rotate the multi-cycle precise potentiometer (the large knob on the front) to generate the desired 4-20mA current signal or voltage signal. The display will show the output value.
  3. Switching Display: To switch between monitoring output current and voltage, press the switch located directly under the LED display.
  4. Coarse and Fine Tuning: The device supports both coarse and fine tuning modes. The minimum adjustment increment for the knob is 0.01mA.
Image showing the signal generator in use, with electrical sparks symbolizing its ability to generate both ampere and voltage signals.
Figure 3: Illustrating the dual signal generation capability.

5. Ampere and Voltage Display Calibration

If the LED display shows an inaccurate value, you can calibrate it using the potentiometers on the back of the module.

  1. Locate Calibration Potentiometers: On the back of the module, there are small potentiometers specifically for current and voltage display calibration.
  2. Adjust for Accuracy: Use a small screwdriver to carefully adjust these potentiometers until the displayed value matches the actual output current or voltage, as measured by a calibrated external meter.
  3. Save Output Value: The device allows saving the output value. Refer to the specific instructions on the device (e.g., "Press the button to save the output value" as indicated near the knob) to store your desired output settings.
Close-up image of the back of the signal generator, highlighting the location of the current and voltage display calibration potentiometers.
Figure 4: Location of calibration potentiometers.

6. Wide Range of Applications

This signal generator is versatile and suitable for a variety of applications, including but not limited to:

  • Signal generation for testing and debugging
  • Valve adjustment in industrial processes
  • Inverter control systems
  • PLC (Programmable Logic Controller) debugging
  • Panel debugging
  • LED testing
  • Analog transmitter output simulation
The signal generator placed in an industrial control room setting, indicating its use in industrial applications.
Figure 5: Application in an industrial control environment.
The signal generator shown in an automotive or machinery setting, suggesting its use in various technical fields.
Figure 6: Application in machinery or automotive systems.

7. Specifications

FeatureDetail
Product Name4-20mA Current Voltage Signal Generator with Battery Power Supply Interface Analog Simulator Adjustable 4 Digit Display
ModelJS-020ISG-S-3L-J4
Batch/Serial NumberALI7410524994
Output Current Range4-20 mA
Power Supply Voltage (Vp)DC24V (15-28V)
Display4-digit 0.4 inch high brightness LED digital tube
Adjustment MethodDigital encoder knob (coarse and fine tuning)
Minimum Adjustment Increment0.01mA
Accuracy after Calibration0.01mA
MaterialABS
WeightApprox. 58g / 2.0oz
Package Dimensions (L x W x H)9 cm x 6 cm x 5 cm
Package Weight0.086 kg
Battery IncludedNo
DIY Supplies CategoryElectrical
OriginMainland China

8. User Tips

  • For critical applications, always verify the output signal with a secondary calibrated measurement device, especially after initial setup or if the device has been moved.
  • When adjusting the potentiometer, make small, incremental changes to achieve the desired output precisely.
  • Keep the device clean and free from dust and debris to ensure optimal performance and longevity of the digital encoder knob and display.
  • If the display appears dim or flickers, check the power supply voltage to ensure it is within the specified 15-28V DC range.

9. Troubleshooting

If you encounter issues with your signal generator, refer to the following common problems and solutions:

  • No Display/No Power:
    • Check power supply connections (V+ and G) for correct polarity and secure contact.
    • Ensure the power supply voltage is within the 15-28V DC range.
  • Inaccurate Output/Display:
    • Perform the Ampere and Voltage Display Calibration as described in Section 5.
    • Verify connections to the device under test.
  • No Signal Output:
    • Check the output connections (OUT and G).
    • Ensure the rotary knob is adjusted to a value within the 4-20mA range.
  • Knob Not Responding:
    • Ensure the knob is clean and free from obstructions. The digital encoder knob is designed to be durable, but extreme environments can affect it.

10. Warranty and Support

For technical support, warranty claims, or further assistance, please contact the manufacturer or the authorized representative:

Manufacturer:

Company Name: Shanghai Ling Watch Oil Co., Ltd
Address: Room 2510, 1st Floor, Building 2, 1858 Jinchang Road, Putuo District, Shanghai
Email: a161sumaitn2821@163.com
Telephone: 86-13876659221

EU Authorized Representative:

Company Name: SOLID AUTHORITY LIMITED
Address: IE-IE-51 Bracken Road, Sandyford, Dublin 18, D18 CV48, Dublin, Ireland
Email: phoebe8706@gmail.com
Telephone: 33-761441379

A PDF version of this user manual is available for download: Download User Manual (PDF)

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.