1. Product Overview
The JIKONG JK BMS PB2A16S20P V19 is an intelligent Battery Management System designed for large-capacity series lithium battery packs. It features voltage acquisition, high-current active balancing, and comprehensive protection functions including overcharge, overdischarge, overcurrent, and overtemperature protection. The system also includes a coulomb meter, Bluetooth communication, and host computer monitoring capabilities.
This BMS is suitable for LiFePo4 and Li-Ion battery types, supporting 8S to 16S configurations. It utilizes energy transfer active balancing technology to achieve a continuous 1A or 2A balance current, ensuring battery consistency, improving range, and extending battery life. A mobile APP (Android/iOS) is available for monitoring battery status, modifying parameters, and controlling charge/discharge switches. The compact design and full functionality make it ideal for high-power energy storage, base station backup power supplies, and solar power applications.
2. Safety Information
Always observe general electrical safety precautions when working with battery management systems. Improper installation or handling can lead to serious injury or damage to equipment. Ensure all connections are correct and secure before applying power.
- Do not short-circuit battery terminals.
- Ensure proper ventilation around the BMS and battery pack.
- Wear appropriate personal protective equipment (PPE) such as insulated gloves and eye protection.
- Do not attempt to repair or modify the BMS unless you are a qualified professional.
- Keep out of reach of children.
3. Package Contents
Verify that all items are present in your package:
| No. | Item | Model | Quantity |
|---|---|---|---|
| 1 | Interface board | JK-CN-Link | 1 |
| 2 | M6 screws | M6*10 | 4 |
| 3 | Adapter cable A (30cm) | HY2.0-XH2.54-22AWG-30CM | 1 |
| 4 | Adapter cable B (30cm) | 2XH2.54-22AWG-30CM | 1 |
| 5 | Adapter cable C (30cm) | IDC2.54mm-20P-30CM | 1 |
| 6 | Dry contact terminal | WJ15EDGK-3.81-4P | 1 |
| 7 | RJ45 network cable (40cm) | CAT5E-8P | 1 |
| 8 | Sampling line A x2 (90cm) | HY2.0-7P-22AWG-90CM-1 | 1 |
| 9 | Sampling line B x1 (90cm) | HY2.0-6P-Blue-22AWG-90CM-2 | 1 |
| 10 | Sampling line C x1 (90cm) | HY2.0-7P-Red-22AWG-90CM-3 | 1 |
| 11 | Sampling line (yellow) | HY2.0-6P-Yellow-22AWG-90CM-4 | 1 |
| 12 | Device activation switch | GH1.25-6P-50CM | 1 |
| 13 | Energy storage board power cable | 18AWG-Red-50CM+M3 copper nose | 1 |
| 14 | Heating cable | OT2.5-3-14AWG-150MM-double head | 1 |
4. Specifications
The JK BMS PB2A16S20P V19 offers robust performance and features for battery management:
| Feature | Specification |
|---|---|
| Model | JK-PB2A16S20P V19 |
| BMS Type | Inverter BMS |
| Battery Strings | 8S-16S |
| Continuous Current | 200A |
| Instantaneous Current | 350A |
| Active Balance Current | 2A |
| Balance Method | Active Balance (Full State On) |
| Battery Type | Li-ion / LiFePo4 / LTO |
| Charging Current | 200A (for 20P model) |
| Discharge Current | 200A (for 20P model) |
| Over Charge Protection (ADJ) | 10-200A |
| Wiring Output | Common Port |
| Other Interfaces (Default) | RS485 / 232 / CAN |
| Single Cell Voltage Range | 1-5V |
| Voltage Acquisition Accuracy | ±5mV |
| Over Charge Protection Voltage | 1.2-4.35V Adjustable |
| Over Charge Release Voltage | 1.2-4.35V Adjustable |
| Over Current Detect Delay | 2-120S (ADJ) |
| Over Discharge Protection Voltage | 1.2-4.35V Adjustable |
| Over Discharge Release Voltage | 1.2-4.35V Adjustable |
| Quantity of Temperature Detection | 4 |
| Temp Protection | Yes |
| Short Circuit Protection | Yes |
| Coulomb Counter | Yes |
| Bluetooth Function | Support for Android/iOS/Harmony |
| Parallel Charging Current Limiting | 10A |
| Address Dial Switch | 4 |
| DRY Contact | 2 |
| Dimensions | 300 x 100 x 24 mm |
| Weight | 1000g |
For more detailed specifications, please refer to the official user manual PDF: JK-Energy Storage Series BMS Product Specification (PDF).
5. Setup and Installation
5.1. Initial Checks and Activation
Before powering on the protection board, ensure the following:
- Verify that the balance cables are correctly connected to the battery cells.
- Confirm that the P- (total negative electrode) and B- (negative pole of battery pack) connections are correct and secure.
- Ensure the protection board is securely fixed to the battery pack.
The BMS is designed for charging activation. After battery assembly, connect a charger (with voltage 2V higher than battery voltage) to activate the protection board. Alternatively, if you have the optional display screen and button, connect them to the display interface and press the button to activate.
5.2. Wiring Diagram
The following diagram illustrates the wiring method for the JK-PB1/2A16S-10/15/20P series protection board, suitable for 7-16 series lithium battery packs. The specific wiring may vary slightly depending on the number of cells in your battery pack.
Wiring Steps:
- First, weld B-, P-, B+, P+, and then insert the battery sampling cable in order from low to high.
- Activate after power on, make sure all cables are correctly connected, and then add the load and charger.
- When disassembling, first disconnect the charger and load, unplug the battery sampling cable in order from high to low, and finally unplug B+, P+, B-, P-.
5.3. Interface Board Connections
The interface board provides various ports for communication and control:
The interface board includes:
- LED Indicator: Shows BMS working status and remaining battery power.
- Reset Switch: Press to reset the BMS if an anomaly occurs.
- Dip Switch: Used to set the communication address for parallel operation (0-15).
- Dry Contact: Two channels for controlling external alarms or fans.
- CAN & RS485-1: For communication between the BMS and inverters.
- RS485-2: For connecting parallel battery packs and communicating with a PC.
For detailed pin definitions of each connector (P1-P7), refer to section 5.2 of the official PDF manual.
5.4. Mobile APP Installation
To install the mobile APP for monitoring and control, scan the QR code below. An Android device with version 7 or higher is required.
6. Operating Instructions
6.1. Active Equalization
The BMS uses active equalization to balance cell voltages. To use this feature, set the battery type, number of cells, battery capacity, and trigger equalization differential pressure (default can be used) in the JIKONG BMS-APP. The default balance current is 1A or 2A, adjustable based on battery capacity. If not needed, disable it in the APP's BMS control page.
6.2. Display Interface (Optional)
If you have the optional display screen, connect it to the reserved display interface on the BMS. This allows for convenient real-time viewing of battery information such as voltage, current, temperature, and State of Charge (SOC).
6.3. Heating Function
The BMS includes a heating function to warm the battery in low-temperature conditions, preventing reduced battery activity. The heating current is 10A. You can control this function via the APP's BMS control page. For extreme cold, it is recommended to install a normally closed temperature switch (45°C to 65°C) in the heating circuit as a secondary safety measure.
6.4. Dry Contact Function
Two dry contacts are provided to control external devices like alarms or cooling fans. These contacts can be configured in the APP to trigger based on overtemperature, overcharge, or overdischarge conditions. Users can select two trigger conditions and customize their settings.
6.5. Discharge Precharge Function
The discharge precharge function is standard, with a default precharge time of 5 seconds. This can be enabled or disabled as needed in the APP. Setting the precharge time to 0 will disable the function.
6.6. Communication Functions (RS485, CAN, Bluetooth)
The BMS supports CAN and RS485 communication. The default CAN communication rate is 250K. Users can select the appropriate protocol in the APP based on their inverter brand and specifications. There are two RS485 interfaces: RS485-1 for inverter communication and RS485-2 for parallel battery pack communication and PC monitoring. The default baud rate for RS485-2 is 115200. Communication addresses (0-15) for parallel systems are set via dip switches.
6.7. Parallel Function
The parallel function allows multiple BMS units to be monitored simultaneously by a PC via the RS485 bus. Up to 16 BMS units are supported. Address 0 is the host, and addresses 1-15 are slaves. The PC connects to the host BMS via a USB to RS485 serial port cable, and slave BMS units are daisy-chained using RJ45 Ethernet cables. Addresses are set using the dip switches on the interface board.
A video demonstrating the V19 BMS and 4.3-inch touch screen in a PB series setup is available:
7. Maintenance
The JIKONG BMS is designed for durability and reliability. Regular maintenance is minimal but important for optimal performance:
- Keep Clean: Periodically clean the BMS board and connections to prevent dust and debris buildup, which can affect performance and heat dissipation.
- Inspect Connections: Regularly check all wiring connections for tightness and signs of corrosion or damage. Loose connections can lead to poor performance or safety hazards.
- Software Updates: Keep the mobile APP and BMS firmware updated to the latest versions to benefit from improvements and bug fixes. Firmware updates can be performed via OTA (Over-The-Air) remote upgrade.
- Environmental Conditions: Ensure the BMS operates within its specified temperature range (-30°C to 70°C) and avoid excessive humidity.
8. Troubleshooting
The BMS incorporates various protection mechanisms to ensure the safety and longevity of your battery system. Here are common issues and their resolutions:
8.1. Protection Triggers
- Overcharge Protection: If any cell voltage exceeds the set overcharge protection voltage, charging will stop. It will resume when all cell voltages drop below the recovery voltage. Adjust settings in the APP if necessary.
- Overdischarge Protection: If any cell voltage drops below the set undervoltage protection voltage, discharge will stop. It will resume when all cell voltages rise above the recovery voltage. The BMS will automatically shut down if any cell drops below the automatic shutdown voltage.
- Overcurrent Protection (Charge/Discharge): If charging or discharging current exceeds the set limit for a specified delay, the respective operation will stop. It will resume after the set release time. Adjust continuous current, delay, and release time in the APP.
- Overtemperature Protection (Charge/Discharge): If the BMS detects temperatures above the set limits, the corresponding operation will stop. It will resume when temperatures return to safe levels.
- Low Temperature Protection (Charge): Charging will stop if temperatures fall below the set low-temperature limit and resume when temperatures rise. Consider using the heating function in cold environments.
- Short Circuit Protection: If a short circuit is detected, the BMS will stop operation. The protection will clear after the set recovery time. If short circuits occur during initial charging or loading, increasing the short circuit protection delay in the APP may help, as it can be caused by high instantaneous currents.
8.2. Emergency Switch
In case of critical issues like persistent over-temperature, over-discharge, over-charge, or a dropped string, activating the emergency switch via the APP's BMS control page will enable charge and discharge for 30 minutes. This provides a temporary window to address the issue or safely manage the battery system.
8.3. Intelligent Sleep
If the BMS enters intelligent sleep mode (due to low current activity for 26 hours), it can be reactivated by pressing the activation button (if installed) or by connecting a charger.
9. User Tips
- Parameter Customization: Take advantage of the APP's parameter setting capabilities to fine-tune the BMS behavior to your specific battery chemistry and application needs.
- Monitoring is Key: Regularly check the battery status via the mobile APP or PC monitoring software to catch potential issues early.
- Parallel System Setup: When setting up a parallel system, carefully follow the dip switch address configuration and wiring instructions to ensure proper communication between BMS units and the host computer.
- Heating in Cold Climates: If operating in cold environments, utilize the heating function and consider adding an external temperature control switch for enhanced safety and battery performance.
10. Warranty and Support
For warranty information, technical support, or service inquiries, please contact your original seller or the JIKONG customer service department. Ensure you have your product model and purchase details available when contacting support.