GEYA GEYA-HT-BOX with Copper Bar

Contents

GEYA HT Series Electrical Distribution Box

Model: GEYA-HT-BOX with Copper Bar

User Manual

1. Introduction

Thank you for choosing the GEYA HT Series Electrical Distribution Box. This product is designed for safe and reliable electrical distribution in various environments, offering robust protection and ease of installation. This manual provides essential information for the proper setup, operation, maintenance, and troubleshooting of your distribution box.

2. Safety Information

WARNING: Electrical shock hazard. Improper installation or use can cause serious injury or death.

  • Always disconnect power at the main supply before performing any installation, wiring, or maintenance.
  • Installation and wiring should only be performed by a qualified and licensed electrician in accordance with all local and national electrical codes.
  • Ensure proper grounding of the distribution box and all connected circuits.
  • Do not operate the distribution box with damaged components or if the enclosure is open or compromised.
  • Verify that the voltage and current ratings of all connected devices are compatible with the distribution box.
  • Keep the distribution box cover securely closed to maintain its IP65 rating and protect against environmental factors.

3. Package Contents

Please check the package for the following items:

  • GEYA HT Series Electrical Distribution Box (selected way: 5, 8, 12, 15, 18, or 24)
  • Copper Bar(s) (for Neutral and Ground connections)
  • DIN Rail (pre-installed)
  • Mounting Kit: 4 x φ6x30 plastic anchors and 4 x M4x25 self-tapping screws
GEYA HT DB Box with DIN rail, copper bars, and mounting screws

Figure 3.1: Typical package contents including the distribution box, DIN rail, copper bars, and mounting hardware.

4. Product Overview

4.1 Key Features

  • IP65 Protection Class: Fully dustproof and resistant to water jets, with sealing gaskets on both cover and base for superior waterproofing.
  • Reinforced Locking & Hinge Design: Thickened lock latches and frame for enhanced durability. Hinge mechanism allows ≥115° opening angle, locks in place, and withstands ≥500 open/close cycles.
  • Secure & Convenient Structure: Non-detachable screws prevent loss during maintenance. External screw placement maintains waterproof integrity.
  • Multi-Ring Knockouts: Pre-marked cable entry sizes with pre-drilled pilot holes for easy conduit fitting.
  • High-Safety Copper Terminals: Terminal blocks pass 960°C glow-wire test for fire resistance, ensuring safety.
  • Material: Bottom shell and face frame made of ABS new material; transparent cover made of PC new material for good toughness, high strength, and impact resistance.
Features of GEYA HT Distribution Box including IP65, reinforced lock, and hinge design

Figure 4.1: Overview of key features including IP65 protection and reinforced design.

Detailed features of GEYA HT Distribution Box showing non-detachable screws, external screw placement, multi-ring knockouts, and copper terminals

Figure 4.2: Detailed features highlighting secure structure and high-safety terminals.

4.2 Components

  • Enclosure: The main body of the distribution box, providing protection for internal components.
  • Transparent Cover: Allows visual inspection of circuit breakers without opening the box.
  • DIN Rail: Standard rail for mounting miniature circuit breakers (MCBs) and other modular devices.
  • Neutral Busbar: Copper bar for connecting all neutral wires.
  • Ground Busbar: Copper bar for connecting all ground (earth) wires.
  • Knockouts: Pre-formed openings on the enclosure sides for cable entry.
Inside view of GEYA distribution box showing DIN rail, neutral and ground copper busbars

Figure 4.3: Internal components including DIN rail and copper busbars.

5. Setup Instructions

5.1 Mounting the Distribution Box

  1. Select Location: Choose a flat, stable surface for mounting, ensuring it is easily accessible and protected from physical damage.
  2. Mark Drilling Points: Hold the distribution box against the mounting surface and mark the four mounting hole positions.
  3. Drill Holes: Drill holes at the marked positions using an appropriate drill bit for the provided plastic anchors (φ6mm).
  4. Insert Anchors: Insert the plastic anchors into the drilled holes.
  5. Secure Box: Align the distribution box with the anchors and secure it using the provided self-tapping screws (M4x25). Do not overtighten.
Multi-ring knockouts on the side of the distribution box

Figure 5.1: Multi-ring knockouts for cable entry.

5.2 Wiring the Distribution Box

IMPORTANT: Ensure main power is OFF before proceeding with wiring.

  1. Open Cover: Unlatch and open the transparent cover of the distribution box.
  2. Prepare Cable Entries: Carefully remove the appropriate multi-ring knockouts on the sides of the enclosure for your incoming and outgoing cables. Use cable glands (not supplied) to ensure IP65 integrity.
  3. Install Circuit Breakers: Mount your miniature circuit breakers (MCBs) or other modular devices onto the pre-installed DIN rail.
  4. Connect Main Power: Route the main incoming live (phase) wire to the input terminal of the main circuit breaker.
  5. Connect Neutral and Ground: Connect all neutral wires to the neutral copper busbar and all ground (earth) wires to the ground copper busbar. Ensure secure connections.
  6. Connect Load Wires: Route outgoing live wires from the circuit breakers to their respective loads.
  7. Verify Connections: Double-check all wiring connections for tightness and correctness according to your electrical diagram.
  8. Close Cover: Once wiring is complete and verified, securely close and latch the transparent cover.
GEYA distribution box with circuit breakers installed and wired

Figure 5.2: Example of circuit breakers installed and wired within the distribution box.

6. Operating Instructions

  1. After successful installation and wiring, restore power to the main supply.
  2. Use the circuit breakers mounted inside the distribution box to control the power supply to individual circuits.
  3. Ensure the transparent cover is always securely closed and latched to maintain the IP65 waterproof and dustproof rating, especially in outdoor or harsh environments.

7. Maintenance

Regular maintenance helps ensure the longevity and safe operation of your distribution box.

  • Visual Inspection: Periodically inspect the enclosure for any signs of physical damage, cracks, or discoloration. Check the integrity of the sealing gaskets around the cover and cable entries.
  • Cleanliness: Keep the exterior of the distribution box clean. Use a soft, damp cloth to wipe away dust and dirt. Do not use abrasive cleaners or solvents.
  • Connection Check: With power disconnected, periodically check all terminal connections for tightness. Loose connections can cause overheating and electrical hazards.
  • Professional Inspection: It is recommended to have a qualified electrician perform a thorough inspection and testing of the electrical system, including the distribution box, at regular intervals.

8. Troubleshooting

If you encounter issues with your distribution box, refer to the following common problems and solutions:

ProblemPossible CauseSolution
No power to a circuitCircuit breaker tripped or OFF; loose wiring connection; no main power supply.Check circuit breaker position and reset if tripped. Verify all wiring connections are secure. Check main power supply.
Water ingress inside boxCover not properly closed; damaged sealing gasket; improper cable gland installation; unused knockouts not sealed.Ensure cover is securely latched. Inspect and replace damaged gaskets. Re-install cable glands correctly. Seal all unused knockouts with appropriate plugs.
Overheating at terminalsLoose wiring connections; overloaded circuit.Disconnect power and tighten all terminal screws. Reduce load on the circuit or redistribute loads. Consult an electrician.

If the problem persists, contact a qualified electrician or the product supplier for assistance.

9. Specifications

AttributeValue
Brand NameGEYA
Model NumberGEYA-HT-BOX with Copper Bar
Product NameHT Distribution Box with Copper Bar
MaterialPC (transparent cover), ABS (bottom shell and face frame)
Waterproof LevelIP65
FunctionFire Resistant
CertificationISO9001, CE
StandardIEC60529 EN60309
Specification (Ways)5-way, 8-way, 12-way, 15-way, 18-way, 24-way

9.1 Dimensions

Dimension diagrams for GEYA HT-5, HT-8, HT-12, and HT-18 distribution boxes

Figure 9.1: Dimension diagrams for various HT Series distribution boxes.

ModelRowsOverall Dimension (L x W x H)
GYHT-5Single row129 x 170 x 95 mm
GYHT-8Single row183 x 170 x 95 mm
GYHT-12Single row255 x 200 x 105 mm
GYHT-15Single row309 x 200 x 105 mm
GYHT-18Single row363 x 200 x 110 mm
GYHT-24Double row272 x 350 x 110 mm

10. User Tips

Based on user feedback, here are some tips for optimal use:

  • Component Sizing: When selecting circuit breakers or contactors, ensure they fit comfortably within the box dimensions. Some users noted that it might be small for larger contactors.
  • Quality Assurance: Users consistently praise the thick, sturdy plastic and overall high-quality construction, confirming its suitability for demanding environments.
  • Check for Discounts: Keep an eye out for available discounts or coin offers when purchasing to get the best value.
  • Verify Contents: Upon arrival, confirm all components are present, including the neutral and ground busbars, DIN rail, and mounting hardware.

11. Warranty and Support

For warranty information, technical support, or any inquiries regarding your GEYA HT Series Electrical Distribution Box, please contact your point of purchase or the official GEYA customer service. Please refer to the detailed user manual available in PDF format for additional information and support.

A comprehensive user manual is available for download: GEYA HT Series Distribution Box User Manual (PDF)

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.