1. Introduction
Thank you for choosing the GEYA HT Series Electrical Distribution Box. This product is designed for safe and reliable electrical distribution in various environments, offering robust protection and ease of installation. This manual provides essential information for the proper setup, operation, maintenance, and troubleshooting of your distribution box.
2. Safety Information
WARNING: Electrical shock hazard. Improper installation or use can cause serious injury or death.
- Always disconnect power at the main supply before performing any installation, wiring, or maintenance.
- Installation and wiring should only be performed by a qualified and licensed electrician in accordance with all local and national electrical codes.
- Ensure proper grounding of the distribution box and all connected circuits.
- Do not operate the distribution box with damaged components or if the enclosure is open or compromised.
- Verify that the voltage and current ratings of all connected devices are compatible with the distribution box.
- Keep the distribution box cover securely closed to maintain its IP65 rating and protect against environmental factors.
3. Package Contents
Please check the package for the following items:
- GEYA HT Series Electrical Distribution Box (selected way: 5, 8, 12, 15, 18, or 24)
- Copper Bar(s) (for Neutral and Ground connections)
- DIN Rail (pre-installed)
- Mounting Kit: 4 x φ6x30 plastic anchors and 4 x M4x25 self-tapping screws

Figure 3.1: Typical package contents including the distribution box, DIN rail, copper bars, and mounting hardware.
4. Product Overview
4.1 Key Features
- IP65 Protection Class: Fully dustproof and resistant to water jets, with sealing gaskets on both cover and base for superior waterproofing.
- Reinforced Locking & Hinge Design: Thickened lock latches and frame for enhanced durability. Hinge mechanism allows ≥115° opening angle, locks in place, and withstands ≥500 open/close cycles.
- Secure & Convenient Structure: Non-detachable screws prevent loss during maintenance. External screw placement maintains waterproof integrity.
- Multi-Ring Knockouts: Pre-marked cable entry sizes with pre-drilled pilot holes for easy conduit fitting.
- High-Safety Copper Terminals: Terminal blocks pass 960°C glow-wire test for fire resistance, ensuring safety.
- Material: Bottom shell and face frame made of ABS new material; transparent cover made of PC new material for good toughness, high strength, and impact resistance.

Figure 4.1: Overview of key features including IP65 protection and reinforced design.

Figure 4.2: Detailed features highlighting secure structure and high-safety terminals.
4.2 Components
- Enclosure: The main body of the distribution box, providing protection for internal components.
- Transparent Cover: Allows visual inspection of circuit breakers without opening the box.
- DIN Rail: Standard rail for mounting miniature circuit breakers (MCBs) and other modular devices.
- Neutral Busbar: Copper bar for connecting all neutral wires.
- Ground Busbar: Copper bar for connecting all ground (earth) wires.
- Knockouts: Pre-formed openings on the enclosure sides for cable entry.

Figure 4.3: Internal components including DIN rail and copper busbars.
5. Setup Instructions
5.1 Mounting the Distribution Box
- Select Location: Choose a flat, stable surface for mounting, ensuring it is easily accessible and protected from physical damage.
- Mark Drilling Points: Hold the distribution box against the mounting surface and mark the four mounting hole positions.
- Drill Holes: Drill holes at the marked positions using an appropriate drill bit for the provided plastic anchors (φ6mm).
- Insert Anchors: Insert the plastic anchors into the drilled holes.
- Secure Box: Align the distribution box with the anchors and secure it using the provided self-tapping screws (M4x25). Do not overtighten.

Figure 5.1: Multi-ring knockouts for cable entry.
5.2 Wiring the Distribution Box
IMPORTANT: Ensure main power is OFF before proceeding with wiring.
- Open Cover: Unlatch and open the transparent cover of the distribution box.
- Prepare Cable Entries: Carefully remove the appropriate multi-ring knockouts on the sides of the enclosure for your incoming and outgoing cables. Use cable glands (not supplied) to ensure IP65 integrity.
- Install Circuit Breakers: Mount your miniature circuit breakers (MCBs) or other modular devices onto the pre-installed DIN rail.
- Connect Main Power: Route the main incoming live (phase) wire to the input terminal of the main circuit breaker.
- Connect Neutral and Ground: Connect all neutral wires to the neutral copper busbar and all ground (earth) wires to the ground copper busbar. Ensure secure connections.
- Connect Load Wires: Route outgoing live wires from the circuit breakers to their respective loads.
- Verify Connections: Double-check all wiring connections for tightness and correctness according to your electrical diagram.
- Close Cover: Once wiring is complete and verified, securely close and latch the transparent cover.

Figure 5.2: Example of circuit breakers installed and wired within the distribution box.
6. Operating Instructions
- After successful installation and wiring, restore power to the main supply.
- Use the circuit breakers mounted inside the distribution box to control the power supply to individual circuits.
- Ensure the transparent cover is always securely closed and latched to maintain the IP65 waterproof and dustproof rating, especially in outdoor or harsh environments.
7. Maintenance
Regular maintenance helps ensure the longevity and safe operation of your distribution box.
- Visual Inspection: Periodically inspect the enclosure for any signs of physical damage, cracks, or discoloration. Check the integrity of the sealing gaskets around the cover and cable entries.
- Cleanliness: Keep the exterior of the distribution box clean. Use a soft, damp cloth to wipe away dust and dirt. Do not use abrasive cleaners or solvents.
- Connection Check: With power disconnected, periodically check all terminal connections for tightness. Loose connections can cause overheating and electrical hazards.
- Professional Inspection: It is recommended to have a qualified electrician perform a thorough inspection and testing of the electrical system, including the distribution box, at regular intervals.
8. Troubleshooting
If you encounter issues with your distribution box, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| No power to a circuit | Circuit breaker tripped or OFF; loose wiring connection; no main power supply. | Check circuit breaker position and reset if tripped. Verify all wiring connections are secure. Check main power supply. |
| Water ingress inside box | Cover not properly closed; damaged sealing gasket; improper cable gland installation; unused knockouts not sealed. | Ensure cover is securely latched. Inspect and replace damaged gaskets. Re-install cable glands correctly. Seal all unused knockouts with appropriate plugs. |
| Overheating at terminals | Loose wiring connections; overloaded circuit. | Disconnect power and tighten all terminal screws. Reduce load on the circuit or redistribute loads. Consult an electrician. |
If the problem persists, contact a qualified electrician or the product supplier for assistance.
9. Specifications
| Attribute | Value |
|---|---|
| Brand Name | GEYA |
| Model Number | GEYA-HT-BOX with Copper Bar |
| Product Name | HT Distribution Box with Copper Bar |
| Material | PC (transparent cover), ABS (bottom shell and face frame) |
| Waterproof Level | IP65 |
| Function | Fire Resistant |
| Certification | ISO9001, CE |
| Standard | IEC60529 EN60309 |
| Specification (Ways) | 5-way, 8-way, 12-way, 15-way, 18-way, 24-way |
9.1 Dimensions

Figure 9.1: Dimension diagrams for various HT Series distribution boxes.
| Model | Rows | Overall Dimension (L x W x H) |
|---|---|---|
| GYHT-5 | Single row | 129 x 170 x 95 mm |
| GYHT-8 | Single row | 183 x 170 x 95 mm |
| GYHT-12 | Single row | 255 x 200 x 105 mm |
| GYHT-15 | Single row | 309 x 200 x 105 mm |
| GYHT-18 | Single row | 363 x 200 x 110 mm |
| GYHT-24 | Double row | 272 x 350 x 110 mm |
10. User Tips
Based on user feedback, here are some tips for optimal use:
- Component Sizing: When selecting circuit breakers or contactors, ensure they fit comfortably within the box dimensions. Some users noted that it might be small for larger contactors.
- Quality Assurance: Users consistently praise the thick, sturdy plastic and overall high-quality construction, confirming its suitability for demanding environments.
- Check for Discounts: Keep an eye out for available discounts or coin offers when purchasing to get the best value.
- Verify Contents: Upon arrival, confirm all components are present, including the neutral and ground busbars, DIN rail, and mounting hardware.
11. Warranty and Support
For warranty information, technical support, or any inquiries regarding your GEYA HT Series Electrical Distribution Box, please contact your point of purchase or the official GEYA customer service. Please refer to the detailed user manual available in PDF format for additional information and support.
A comprehensive user manual is available for download: GEYA HT Series Distribution Box User Manual (PDF)