1. Introduction
The WapoRich 1600B-APP Non-Contact Infrared Thermometer is a high-precision instrument designed for fast, safe, and accurate temperature measurement across various applications, including industrial testing, HVAC maintenance, mechanical equipment, cooking, and outdoor work. It features a large screen, rechargeable battery, silicone buttons, and an IMD panel for durability and ease of use. This device supports mobile APP connectivity for advanced data recording and real-time monitoring.
How It Works
An infrared thermometer measures an object's surface temperature by sensing emitted, reflected, and transmitted energy. The unit's optics collect and focus this energy onto a detector. The internal electronics then process this energy, displaying the temperature on the unit. A laser pointer enhances aiming precision for increased ease and accuracy.
2. Safety Precautions
- Laser Safety: Do not point the laser directly at eyes or indirectly off reflective surfaces.
- Electromagnetic Fields (EMF): Protect the thermometer from strong EMF generated by arc welders or induction heaters.
- Thermal Shock: If moving the unit between environments with large or abrupt temperature changes, allow 1 hour for the unit to stabilize with the ambient temperature before use.
- High Temperatures: Do not leave the unit on or near objects of extremely high temperature.
- Cleaning: Do not use solvents to clean the lens and do not submerge the unit in water.
3. Package Contents
Please check the box for the following items:
- 1 × WapoRich 1600B-APP Non-Contact Infrared Thermometer
- 1 × Storage Bag
- 1 × Screwdriver
- 1 × TYPE‑C Charging Cable
- 1 × User Manual
- 1 × Packaging Box
4. Setup
4.1. Battery Installation
- Before first use, use the included screwdriver to unscrew the battery cover.
- Open the battery cover and locate the battery cable interface.
- Connect the battery cable, ensuring correct polarity.
- Close the battery cover and secure it with the screws.
4.2. Charging
When the battery symbol appears on the display, the battery needs charging. Connect the TYPE-C USB charging cable to a DC-5V power adapter and then to the thermometer's TYPE-C USB charging port.
4.3. APP Download and Installation
The thermometer can connect to the "Intelligent Meter" mobile application for enhanced functionality. Scan the QR code below or search for "Intelligent Meter" in your device's APP Store or Google Play to download and install the application.
4.4. APP Account Registration and Device Pairing
- Open the "Intelligent Meter" APP.
- For new users, register an account by entering your email and a password, then click "Register". This account will be used for future logins.
- For existing users, log in with your registered email and password.
- To add the device, click the "Add device" button within the app.
- Select the equipment to be added (Infrared Thermometer) and follow the on-screen instructions to complete the pairing process.
- Once paired, click "Start using" to access the thermometer's functions via the app.
5. Operation
The thermometer features a clear LCD display and intuitive controls.
5.1. Basic Measurement
To take a measurement, simply press and hold the TEST button, aim the laser at the object, and read the surface temperature displayed on the screen. Release the TEST button to hold the data. The device automatically turns off after 30 seconds of inactivity.
5.2. Display Features (Figure 1 from manual)
The LCD display shows various indicators:
- A: Data Hold (HOLD)
- B: Main display value (15mm high characters)
- C: Memory storage (REC)
- D: Maximum temperature (MAX)
- E: Continuous measurement
- G: High temperature alarm temperature (HAL)
- H: Alarm of high temperature prompt
- I: Alarm of Low temperature prompt
- J: Low temperature alarm temperature (LAL)
- K: Battery voltage Low
- L: Backlight symbol
- M: Additional features
- N: Minimum temperature (MIN)
- O: Average temperature (AVG)
- P: Maximum and minimum difference (DIF)
- Q: Temperature unit (°C/°F)
- R: Laser pointer turn on prompt
- S: Emissivity symbol
- T: Measuring symbol
5.3. Button Functions
- TEST Button: Press and hold to measure. Release to hold data. Automatically powers off after 30 seconds of no operation.
- Laser Button (
): Press to toggle the laser pointer on/off. The laser symbol will appear/disappear on the display. - Backlight/UP Button (
): Press to turn the backlight on/off. In setting/query status, it functions as an 'Up' adjustment. - MODE Button: Cycles through measurement modes: REC (record), MAX (maximum), MIN (minimum), DIF (difference), AVG (average), HAL (high alarm limit), LAL (low alarm limit).
- T/DN Button: Press to switch between Celsius (°C) and Fahrenheit (°F). In setting/query status, it functions as a 'Down' adjustment.
- E Button (
): Enters emissivity setting mode. Use Backlight/UP to increase and T/DN to decrease emissivity. Press and hold to toggle the flashlight on/off.
5.4. Distance-to-Spot Ratio (D:S)
The thermometer has a D:S ratio of 30:1. This means that the diameter of the measurement spot increases with distance. For accurate readings, ensure the target object is larger than the measurement spot. For critical accuracy, the target should be at least twice the size of the spot. The test distance should not exceed 30 times the diameter of the temperature measuring area.
5.5. Emissivity Adjustment
Emissivity (ε) is adjustable from 0.1 to 1.0. Most organic materials and painted/oxidized surfaces have an emissivity of 0.95. Shiny or polished metal surfaces can result in inaccurate readings. To measure such surfaces, cover them with masking tape or flat black paint and measure the covered area once it reaches the same temperature as the underlying material.
Refer to the table below for common material emissivity values:
| Material | Emissivity | Material | Emissivity |
|---|---|---|---|
| Asphaltum | 0.90 to 0.98 | Textile (Black) | 0.98 |
| Beton | 0.94 | Human Skin | 0.98 |
| Cement | 0.96 | Soap bubble | 0.75 to 0.80 |
| Sand | 0.90 | Charcoal (powder) | 0.96 |
| Soil | 0.92 to 0.96 | Lacquer | 0.80-0.95 |
| Water | 0.92 to 0.96 | Lacquer (reluster) | 0.97 |
| Ice | 0.96 to 0.98 | Rubber (Black) | 0.94 |
| Snow | 0.83 | Plastic | 0.85-0.95 |
| Glass | 0.90 to 0.95 | Timber | 0.90 |
| Ceramic | 0.90 to 0.94 | Paper | 0.70-0.94 |
| Marble | 0.94 | Chromic oxide | 0.81 |
| Gypsum | 0.80 to 0.90 | Copper Oxide | 0.78 |
| Compo | 0.89 to 0.91 | Iron Oxide | 0.78 to 0.82 |
| Brick | 0.93 to 0.96 | Stainless steel | 0.2-0.3 |
5.6. APP Control and Data Management
Connect the thermometer to the "Intelligent Meter" APP via Bluetooth for advanced control and data features:
- Remote Measurement: Initiate and stop measurements from your mobile device.
- Real-Time Monitoring: View live temperature readings on your phone.
- Historical Data: Access and review recorded temperature data.
- Data Export: Download historical data for analysis.
- Settings: Adjust emissivity, alarm settings, and auto-shutdown time directly from the app.
6. Maintenance
6.1. Lens Cleaning
Gently blow off any loose particles using clean compressed air. Carefully brush away remaining debris with a moist cotton cloth. Do not use solvents on the lens.
6.2. Case Cleaning
Clean the device's case with a damp sponge or cloth and mild soap.
6.3. Battery Care
If the thermometer will not be used for an extended period, it is recommended to remove the battery to prevent discharge.
6.4. Emissivity Reset
After replacing the battery, the emissivity setting will revert to its initial value of 0.95. Remember to adjust it again if your application requires a different emissivity setting.
7. Specifications
| Feature | Specification |
|---|---|
| Model Number | 1600B-APP |
| Theory | Infrared Thermometer |
| Temperature Range | -50℃ to 1600℃ (-58℉ to 2912℉) |
| Accuracy | ±4℃/7.2℉ (-50℃ to 0℃), ±(2% reading +2℃/3.6℉) (0℃ above) |
| Distance Spot Ratio (D:S) | 30:1 |
| Emissivity | 0.1-1.0 adjustable |
| Resolution | 0.1℃ (0.1℉) < 1000, 1℃ (1℉) > 1000 |
| Repeatability | 1% of reading or 1℃ |
| Response Time | <250msec, 95% response |
| Spectral Response | 8-14um |
| Operating Temperature | 0℃ to ~40℃ (32 to 104℉) |
| Storage Temperature | -20~60℃ (-4~140℉) without battery |
| Relative Humidity | Operating: 10-95%RH; Storage: 10-95%RH |
| Ambient Temp Range for Accuracy | 23℃~28℃ |
| Weight/Dimensions | 236g; 195×110×60mm |
| Power Type | Rechargeable lithium battery 3.7V 400mAh |
| Battery Life (Laser models) | 12hrs |
| Certification | CE |
| Data Record | Yes |
| Is Smart Device | Yes |
| Display Type | DIGITAL |
8. Troubleshooting
- Reading Not Changing: If the display reading does not change during a test, check if "REC" (record mode) is active on the screen. If so, turn off the record mode to display normal measurement readings.
- High/Low Temperature Alarm: If the LCD displays "HI" or "LOW", it indicates that the measured temperature has exceeded the set high (HAL) or fallen below the set low (LAL) alarm temperature. Adjust the alarm limits as needed via the MODE button.
9. User Tips
- For optimal accuracy, ensure that the target object completely fills the measurement spot indicated by the laser.
- Always adjust the emissivity setting to match the material being measured for the most precise results.
- When moving the thermometer between environments with significant temperature differences, allow it to acclimate for approximately 30 minutes to ensure stable and accurate readings.
- Utilize the mobile APP for continuous monitoring and data logging, especially for long-term projects or when remote observation is required.
10. Warranty and Support
For any problems or concerns regarding your WapoRich 1600B-APP Infrared Thermometer, please contact customer support via email at AFTERSALES1010@HOTMAIL.COM.
To ensure a prompt resolution, please include the following information in your email:
- Order Number
- Platform of Your Purchase
- Full Model Number (1600B-APP)
- Detailed Description of the Problem (attaching videos or photos can help troubleshoot faster)
A PDF version of this user manual is available for download. Please refer to the product page or contact support for the link.