This manual provides detailed instructions for the installation, operation, and maintenance of your Din Rail Digital Power Energy Meter. This 6-in-1 device is designed to accurately measure various electrical parameters in AC 40-300V 100A systems, offering comprehensive energy monitoring for residential or commercial applications.

Key Features:

  • 6-in-1 Measurement: Measures Voltage (AC 40-300V), Current (0-100A), Active Power (0-30000W), Energy (0-99999kWh), Frequency (45-65Hz), and Power Factor (0.00-1.00PF).
  • Data Storage: Retains energy consumption data even during power outages.
  • High Safety & Accuracy: Constructed from high-quality ABS flame-retardant material and equipped with precision chips for reliable measurements.
  • Enhanced Visual Experience: Features a colorful LCD HD display with a 178° wide viewing angle and backlight for clear visibility day and night.
  • Real-Time Monitoring: Monitors real-time household electricity consumption and can measure non-standard sine waves from inverters.

2. Safety Warnings and Precautions

WARNING: Read all instructions carefully before using this product. Keep this manual for future reference.

  • Intended Use: Do not use the product for any purpose other than its intended use. Misuse may cause injury, damage to the product, or other hazards.
  • Children Safety: Keep this product out of the reach of children under 3 years, unless under direct adult supervision. Small parts may cause choking hazard. Not suitable for children under 36 months.
  • No Disassembly: Do not disassemble, modify, or repair the product yourself. Improper operation may cause electric shock, fire, or product failure. Contact professional maintenance personnel if needed.
  • Power Safety: Before use, ensure the power outlet is intact and undamaged.
  • Avoid Moisture: Do not use the product outdoors during rain or in high-humidity environments. Avoid contact with liquids to prevent electric shock. Unplug the power supply when not in use or during cleaning.
  • Prevent Dropping: Avoid dropping the product from elevated positions to prevent damage.
  • Disposal: Dispose of the product and its packaging in accordance with EU WEEE (Waste Electrical and Electronic Equipment) Directive 2012/19/EU and RoHS Directive 2011/65/EU. Do not discard as household waste.
  • Protective Equipment: Protective equipment should be worn during installation and handling.

3. Specifications

ParameterValue
Model NumberPower Energy Meter (D52-2066)
Display TypeDigital Only (LCD HD with backlight)
Operating VoltageAC 40.0-300.0V (for 110V/220V systems)
Current Range0.00-100.0A universal
Active Power Range0-30000W
Frequency Range45.0Hz-65.0Hz
Energy (Electricity) Range0-99999Kwh
Power Factor Range0.00-1.00PF
Product Dimensions80.00mm x 64.00mm x 54.00mm (3.15in x 2.52in x 2.13in)
DIY Supplies CategoryMetalworking
Battery IncludedNo
CertificationNone

Product Dimensions:

Dimensions of the Din Rail Digital Power Energy Meter

Image: Product dimensions showing length (80.00mm), width (64.00mm), and height (54.00mm).

4. Package Contents

The package includes:

  • 1 x Din Rail Digital Power Energy Meter

5. Installation and Setup

5.1 Unpacking Inspection

After opening the package, verify that the product is complete and undamaged. If any components are missing or damaged, do not proceed with installation and contact customer support.

5.2 Wiring Instructions

Important Note: This meter can only be used to measure 45-65Hz AC mains. Ensure the power supply is disconnected before performing any wiring.

  1. Connect Measured Voltage: Connect the AC voltage to be measured to terminals 1 and 2 on the meter.
  2. Internal Current Transformer (CT) Connection:
    Wiring diagram for internal current transformer

    Image: Wiring diagram showing the meter connected to a circuit with an internal current transformer. The main cable (Live/Neutral) passes through the round hole on the right side of the meter. Input AC voltage is connected to terminals 1 and 2. The direction of insertion of the wire in the hole does NOT affect the reading of the Current (A).

    Pass one of the main cables (Live/Neutral) through the round hole on the right side of the meter. The direction of insertion of the wire does not affect the current reading.

  3. External Current Transformer (CT) Connection (if applicable):

    If using an external current transformer (not included), pass the main cable through the hole on the external CT. Then, connect the two wires of the secondary transformer from the external CT to terminals 3 and 4 on the meter.

6. Operating Instructions

6.1 Normal Operation

  1. After correct installation and wiring, power on the device.
  2. The meter will display the measured parameters (voltage, current, active power, energy, frequency, and power factor) on its LCD screen.
  3. Operate the device according to the instructions provided.

6.2 Energy Data Reset

The meter retains energy consumption data even after power is turned off. To reset the accumulated energy (electricity) value to zero:

  • When the meter is turned on, press and hold the 'RESET' button (labeled 'SAM CK' in some diagrams) for 5 seconds.
  • Release the button, and the energy accumulation will restart from zero.

7. Cleaning and Maintenance

  • Cleaning: Wipe off surface dust or stains promptly after use with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Storage: When not in use for extended periods, store the product in a dry, well-ventilated location, away from direct sunlight and extreme temperatures.

8. Troubleshooting

If you encounter issues with your energy meter, consider the following:

  • No Display/Incorrect Readings:
    • Ensure the measured voltage is correctly connected to terminals 1 and 2.
    • Verify that the main cable is properly passed through the current transformer hole.
    • Check if the power supply is stable and within the specified AC 40-300V range.
  • Energy Data Not Resetting:
    • Ensure you are pressing and holding the 'RESET' button for the full 5 seconds.
  • Meter Not Powering On:
    • Check the power source and connections to terminals 1 and 2.
    • Ensure the power outlet is functional.

For persistent issues or complex problems, contact qualified electrical personnel or customer support for assistance. Do not attempt unauthorized repairs.

9. User Tips

  • For optimal readability, position the meter where the LCD screen is easily visible, taking advantage of its wide viewing angle.
  • Regularly check the displayed parameters to monitor your electricity usage and identify potential energy-saving opportunities.
  • When installing, ensure all connections are secure to prevent intermittent readings or safety hazards.

10. Warranty and Support

For warranty information, technical support, or service inquiries, please refer to the seller's policies or contact the point of purchase. Keep your purchase receipt as proof of purchase.

A digital version of the user manual (PDF) may be available for download from the seller's website or by contacting customer support.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.