KKMOON TSG-17

Contents

TSG-17 High-Frequency Signal Generator

User Manual

Brand: KKMOON | Model: TSG-17

1. Product Information

The TSG-17 is a high-frequency, high-accuracy signal generator designed to provide stable RF and AM signals for various electronic devices and circuits. Its advanced circuit design ensures minimal accuracy deviation, making it a reliable tool for testing and measurement.

  • Product Name: TSG-17 100KHz-150MHz Function Generator High-Frequency High-Accuracy Signal Generator 10A-18A
  • Model: 11102100405
  • Batch/Serial Number: ALI5545957646
  • Material: Iron (wear-resistant and durable)
  • Key Features: Small size, light weight, and portability for versatile use.
TSG-17 Signal Generator on a circuit board background
Figure 1: Handheld Function Generator. Advanced circuit design ensures high accuracy.

2. Setup

Before operating the TSG-17 signal generator, ensure it is properly set up.

  1. Unpacking: Carefully remove the signal generator and all accessories from the packaging.
  2. Power Connection: Connect the provided power cable to the device and then to a suitable power outlet. Ensure the power switch on the front panel is in the 'OFF' position before connecting to power.
  3. Test Lead Connection: Connect the signal test line to the appropriate output port (e.g., RF OUTPUT or MOD.IN/AUDIO OUT) as required for your application.
Front panel of TSG-17 signal generator with connected power and test leads
Figure 2: Front Panel and Connections. Illustrates power and signal lead connections.

3. Operating Instructions

The TSG-17 provides high-frequency signals and modulation capabilities. Follow these steps for operation:

  1. Power On: Flip the red 'POWER' switch on the front panel to the 'ON' position.
  2. Select Frequency Range: Use the 'RANGE' selector buttons (A, B, C, D, E, F) to choose the desired frequency band.
  3. Adjust Frequency: Rotate the large 'FREQUENCY' dial to fine-tune the output frequency within the selected range.
  4. Adjust RF Output Level: Use the 'RF LEVEL' knob to control the amplitude of the RF output signal (1mV-100mV).
  5. Modulation Settings:
    • MOD.MODE: Select 'INT' for internal modulation (1KHz) or 'EXT' for external modulation.
    • MOD LEVEL: Adjust the modulation depth.
    • MOD FREQUENCY: Adjust the frequency of the internal modulation signal.
    • External Modulation: If 'EXT' is selected, an external modulation signal (50Hz~20KHz) can be applied via the 'MOD.IN/AUDIO OUT' port. The 1KHz modulation signal can reach 80% or 100% overmodulation.
  6. Output: The generated signal is available at the 'RF OUTPUT' port.
TSG-17 Signal Generator in a city night scene, labeled Testing Tool
Figure 3: Testing Tool. Generates signal frequencies from 100KHz to 150MHz, with third harmonics up to 450MHz.
TSG-17 Signal Generator with satellite dishes in the background, labeled Signal Generator
Figure 4: Signal Generator Capabilities. Supports large-scale signal conversion and flexible modulation.

4. Maintenance

To ensure the longevity and optimal performance of your TSG-17 signal generator, follow these maintenance guidelines:

  • Cleaning: Keep the device clean by wiping it with a soft, dry cloth. Avoid using abrasive cleaners or solvents.
  • Storage: Store the signal generator in a cool, dry place away from direct sunlight, dust, and extreme temperatures.
  • Handling: Handle the device with care to prevent physical damage. The iron material construction provides durability.
  • Power Off: Always power off the device and disconnect it from the power source when not in use for extended periods.
TSG-17 Signal Generator with a close-up inset of its side, labeled Multifunctional Signal Generator
Figure 5: Multifunctional Signal Generator. Constructed from durable iron material for extended service life.

5. Troubleshooting

If you encounter issues with your TSG-17 signal generator, consider the following basic troubleshooting steps:

  • No Power:
    • Check if the power cable is securely connected to both the device and the power outlet.
    • Ensure the power outlet is functional.
    • Verify the power switch is in the 'ON' position.
  • No Output Signal:
    • Check if the test leads are correctly connected to the 'RF OUTPUT' port and your measuring device.
    • Ensure the 'RF LEVEL' knob is not set to minimum.
    • Verify that a frequency range is selected and the frequency dial is set.
  • Incorrect Signal:
    • Confirm the selected frequency range and dial setting match your desired output.
    • Check modulation settings if an AM signal is expected.

If problems persist after these steps, please contact customer support.

6. Specifications

Parameter Value
ModelTSG-17
MaterialIron
Frequency Range100KHz-150MHz
Frequency Accuracy±5%
Output WaveformRF/AM Signal Waveform
Output Impedance600Ω
RF Output>100Mvrms (Range Frequency≤35MHz)
Level Control1mV-100mV
External Modulation150Hz-1.5KHz, Amplitude modulation approx. 0-30% adjustable
Working Environment50Hz-20KHz

Frequency Bands:

  • A: 100KHz-300KHz
  • B: 300KHz-1MHz
  • C: 1MHz-3.2MHz
  • D: 3MHz-10MHz
  • E: 10MHz-35MHz
  • F: 32MHz-150MHz

7. User Tips

Based on available information, no specific user tips or common usage advice were provided in buyer reviews or Q&A content for this product.

8. Warranty & Support

For product support, warranty claims, or technical assistance, please contact the manufacturer or their authorized representative:

Manufacturer Information:

Company Name: shanghai huang shi mao yi Co., Ltd.
Full Address: Room 3389, Building 2, No. 88, Changxu Road, Juyuan New District, Jiading District, Shanghai
Email: b162sumaitn2822@163.com
Telephone: 86-13876659222

EU Authorized Representative:

AR Company Name: SOLID AUTHORITY LIMITED
Full Address: IE-51 Bracken Road, Sandyford, Dublin 18, D18 CV48, Ireland
Email: phoebe8706@gmail.com
Telephone: 33-761441379

Compliance Information:

WARNING: To avoid danger of suffocation, keep this plastic bag away from babies and children.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.