1. Introduction

Thank you for purchasing the Gaqqee Model 602 Carbon Monoxide Alarm. This device is designed to detect carbon monoxide (CO) gas and alert you to potentially dangerous levels, helping to ensure the safety of your home or other indoor environments. Featuring a highly sensitive sensor, an LCD display for concentration readings, and easy, wire-free installation, this alarm provides reliable protection.

Carbon monoxide is a colorless, odorless, and tasteless gas that can be deadly. It is produced when fuels burn incompletely. Common sources include gas stoves, water heaters, barbecue grills, and coal heating systems. This alarm is an essential tool for early detection.

Front view of the Gaqqee Carbon Monoxide Alarm with LCD display showing '000 ppm'.
Figure 1: Front view of the Carbon Monoxide Alarm

2. Safety Information

WARNING: This carbon monoxide alarm is designed to detect carbon monoxide gas. It is not a smoke detector or a fire alarm. It is not a substitute for proper maintenance of fuel-burning appliances.

  • Never ignore a CO alarm. Act immediately if the alarm sounds.
  • Carbon monoxide poisoning symptoms can include breathing difficulties, headache, and nausea. Prolonged exposure can be fatal.
  • Ensure proper ventilation in areas with fuel-burning appliances.
  • Do not paint over the alarm or block its vents.
  • Keep the alarm clean and free from dust.
Image showing three people experiencing symptoms of carbon monoxide poisoning: breathing difficulties, headache, and nausea.
Figure 2: Symptoms of Carbon Monoxide Poisoning
Four images depicting common causes of carbon monoxide production: kitchen gas stove, coal heating, restaurant hot pot rooms, and burning honeycomb briquettes.
Figure 3: Causes of Carbon Monoxide Production

3. Package Contents

Please check the package contents upon opening to ensure all items are present:

  • Carbon Monoxide Alarm (x1)
  • Screws (x2)
  • Instruction Manual (x1)
Image showing the Carbon Monoxide Alarm, user manual, and mounting screws included in the package.
Figure 4: Package Contents

4. Features

  • Flame Retardant Material: Manufactured using ABS flame-retardant material, resistant to high temperatures and deformation.
  • Easy Installation: Simply insert batteries; no wiring required, making installation simple and convenient.
  • LCD Screen Display: Backlit digital display for gas concentration, providing clear and easy-to-read readings.
  • Gas-Sensitive Sensor: Electronic sensitive sensor capable of rapid detection and alarm activation, eliminating false alarms and missed detections.
  • Wide Range of Applications: Widely applicable in kitchens, vehicle cabins, indoor coal stove heating, long-term enclosed spaces with heating systems, and hot pot private rooms in restaurants.
Image highlighting the flame-retardant material of the CO alarm.
Figure 5: Flame-Retardant Material
Image showing the backlit LCD screen display of the CO alarm.
Figure 6: LCD Screen Display
Image emphasizing the gas-sensitive sensor of the CO alarm.
Figure 7: Gas-Sensitive Sensor
Image showing various application environments for the CO alarm, including kitchens, vehicle cabins, living rooms, and commercial spaces.
Figure 8: Wide Range of Applications

5. Specifications

Parameter Value
Product Name Carbon Monoxide Alarm
Model Number 602
Color White
Application Indoor
Installation Method Wall Mounted
Working Voltage DC 4.5V
Working Temperature 0°C ~ 50°C
Standby Current 30 mA
Alarm Current 35 mA
Alarm Sound 85 dB
Detection Range 0 ~ 999 ppm
Power Supply 3 AA Batteries (not included)
Alarm Mode Sound + Flash
Detected Gas CO (Carbon Monoxide)
Alarm Concentration 100 ~ 150 ppm
Product Dimensions 98 * 98 * 35 mm
Image showing detailed product specifications for the Carbon Monoxide Alarm.
Figure 9: Product Specifications
Image showing the dimensions of the Carbon Monoxide Alarm: 98mm by 98mm.
Figure 10: Product Dimensions

6. Setup

6.1 Battery Installation

  1. Remove the back cover of the alarm by twisting it counter-clockwise.
  2. Insert three (3) AA 1.5V batteries into the battery compartment, ensuring correct polarity (+/-).
  3. Replace the back cover by twisting it clockwise until it clicks securely into place.
  4. The alarm will perform an initial self-check upon battery insertion.
Diagram showing the battery compartment of the Carbon Monoxide Detector, indicating slots for three 1.5V AA batteries.
Figure 11: Battery Compartment
Play video
Watch video online

Video 1: Product overview and battery installation demonstration (0:01-0:07).

6.2 Mounting the Alarm

The alarm is designed for wall-mounted installation. Choose a suitable location based on the recommendations below.

  1. Mark the desired mounting location on the wall.
  2. Drill two holes at the marked spots, ensuring they align with the mounting holes on the back of the alarm.
  3. Insert the provided screws into the drilled holes, leaving a small gap for the alarm to hang.
  4. Hang the alarm securely on the screws.
Back view of the CO alarm, illustrating easy wall installation with mounting holes.
Figure 12: Easy Wall Installation

6.3 Placement Recommendations

For optimal performance and safety, consider the following when choosing a location for your CO alarm:

  • Install at least one alarm on each level of your home, especially near sleeping areas.
  • Place alarms in rooms with fuel-burning appliances (e.g., kitchens, utility rooms with furnaces or water heaters).
  • In rooms with sloped ceilings, install the alarm at the highest point.
  • Avoid placing the alarm directly above heat sources or in areas with high humidity.
  • The alarm is suitable for kitchens, vehicle cabins, indoor coal stove heating areas, long-term enclosed heating rooms, and restaurant hot pot private rooms.

7. Operating the Alarm

7.1 Initial Power-On

After installing the batteries, the alarm will automatically power on and initiate a self-check sequence. The LCD display will show "000 ppm" and the alarm will emit a short beep to indicate it is functioning correctly. It will then enter power-saving mode within two seconds.

7.2 Self-Check / Test Function

It is recommended to test your CO alarm weekly to ensure it is working properly:

  1. Press and hold the "TEST/RESET" button located on the front of the alarm.
  2. The alarm will emit a loud sound and the red LED will flash, indicating the alarm is functioning.
  3. Release the button. The alarm will return to normal monitoring mode.
Play video
Watch video online

Video 2: Self-check/reset key demonstration (0:08-0:11, 0:23-0:27).

7.3 Alarm Indication

When carbon monoxide concentration reaches 100-150 ppm, the alarm will activate:

  • The LCD display will show the detected CO concentration.
  • The alarm will emit a loud 85 dB sound.
  • A red LED light will flash.

If the alarm sounds, immediately move to fresh air and call emergency services.

8. Maintenance

8.1 Battery Replacement

The alarm is powered by three AA batteries. When the batteries are low, the alarm will typically indicate this with a low battery warning (e.g., a chirp or a low battery icon on the LCD). Replace all three batteries simultaneously with new, high-quality AA 1.5V batteries. Refer to Section 6.1 for battery installation steps.

8.2 Cleaning the Alarm

To maintain optimal performance, clean your CO alarm regularly:

  • Gently wipe the exterior of the alarm with a soft, damp cloth.
  • Do not use cleaning sprays, solvents, or abrasive cleaners.
  • Do not paint the alarm.
  • Vacuum any dust from the alarm's vents using a soft brush attachment.

9. Troubleshooting

Problem Possible Cause Solution
Alarm does not power on Batteries are not installed or are dead/incorrectly inserted. Install new AA batteries, ensuring correct polarity.
Alarm chirps periodically Low battery warning. Replace all three AA batteries.
Alarm sounds unexpectedly (false alarm) High humidity, dust, or interference from strong chemicals. Relocate the alarm, clean it, or ensure proper ventilation. If it persists, treat as a real alarm.
LCD display is blank or unreadable Low battery or unit malfunction. Replace batteries. If issue persists, contact support.

10. User Tips

  • Regularly check the LCD display to monitor CO levels, even if the alarm is not sounding.
  • Familiarize yourself with the sound of the alarm so you can recognize it immediately in an emergency.
  • Educate all household members about the dangers of CO and what to do if the alarm sounds.
  • Consider having a professional inspect your fuel-burning appliances annually.

11. Warranty and Support

For any product inquiries, technical support, or warranty claims, please contact your seller or the manufacturer directly. Keep your purchase receipt as proof of purchase.

Manufacturer: Shenzhen Rongbo Jiachuang Technology Co., Ltd

EU Representative: SUCCESS COURIER SL

For detailed product guides and documents, you may refer to the official PDF manual: View User Manual (PDF)

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.