1. Introduction

This manual provides essential information for the safe and efficient operation of your Sumry 3600W Hybrid Solar Inverter. This inverter is designed for both on-grid and off-grid solar power systems, featuring a 120A MPPT solar charger, 24V battery compatibility, and dual output. It delivers a pure sine wave output and can function with or without a battery. Please read this manual thoroughly before installation and use.

2. Safety Information

WARNING: HIGH VOLTAGE. This device operates with high voltages. Improper installation or use can result in serious injury or death. All electrical work should be performed by qualified personnel in accordance with local electrical codes and regulations.

  • Always disconnect all power sources (AC, DC, and battery) before performing any maintenance or installation.
  • Ensure proper grounding of the inverter.
  • Do not open the inverter casing unless specifically instructed by this manual or qualified service personnel.
  • Keep children away from the inverter and wiring.
  • Install the inverter in a well-ventilated area, away from flammable materials and moisture.
  • Use appropriate personal protective equipment (PPE) when working with electrical systems.

3. Product Overview

3.1 Key Features

  • Pure sine wave solar inverter (on/off Grid functionality).
  • Output power factor 1.0.
  • WIFI & GPRS connectivity available for iOS and Android monitoring (optional module required).
  • Ability to run without a battery.
  • One-key restoration to factory settings.
  • Built-in Lithium battery automatic activation.
  • AC output voltage 120VAC.
  • Built-in 120A MPPT Solar charge controller, supporting up to 4200W PV input (for 3.6kW model).
  • High PV input voltage range (60~500VDC).
  • Built-in anti-dust kit for harsh environments.
  • Smart battery charge design to optimize battery life.
  • Dual AC output.
  • Multi-functional safety protection: Overload Protection, Short Circuit Protection, Battery Protection, Overheating Protection, Overcurrent Protection, High/Low Voltage Protection.

3.2 Components and Connections

The inverter features a user-friendly display and control buttons on the front. The rear panel provides all necessary connection terminals and cooling fans.

Sumry 3600W Hybrid Solar Inverter front view with key features
Figure 1: Front view of the Sumry 3600W Hybrid Solar Inverter, highlighting its main specifications.
Sumry 3600W Hybrid Solar Inverter connected to 24V batteries
Figure 2: The inverter connected to 24V batteries, illustrating battery compatibility and maximum charging currents.
Intelligent Cooling Fan system of the Sumry Inverter
Figure 3: Intelligent Cooling Fan system, which adjusts fan speed based on ambient temperature and load.
Multi-functional safety protection features of the inverter
Figure 4: Overview of the inverter's multi-functional safety protection features.

3.3 Product Demonstration Video

Video 1: A brief demonstration of the Sumry Hybrid Solar Inverter's features and operation, including unboxing and basic power output tests.

4. Specifications

The following table details the technical specifications for the Sumry 3600W Hybrid Solar Inverter (Model: MPS VIII ECO).

Attribute Value
Model NumberMPS VIII ECO
Rated Output Power3600W/3600VA
Maximum PV Input Power4200W
Maximum Solar Charging Current120A
Nominal DC Voltage/Maximum DC Voltage360/500VDC
MPPT Voltage Range60~450VDC
Maximum Input Current1/18A
Nominal Output Voltage120VAC (100/105/115V settable)
Output Voltage Range90-150VAC
Nominal Output Current30A
Output Frequency50/60Hz
Maximum Conversion Efficiency (DC/AC)98%
Full Load3600W
Size48*30*18CM
Weight10kg
Output TypeSINGLE
Is Smart DeviceNo
OriginMainland China
CertificationCE
Operating Environment5% to 95% Relative Humidity (Non-condensing), -10°C~50°C
Communication PortRS232/RS485/WIFI/GPRS/LITHIUM BATTERY
FeatureWork without battery, reverse the flow of excess current back into the grid, Pure sine wave, on/off Grid inverter, hybrid solar inverter
Product Data Sheet with detailed specifications for Sumry inverters
Figure 5: Detailed Product Data Sheet, including specifications for both 3.6KW and 6.2KW models.

5. Setup and Installation

Proper installation is crucial for the safe and efficient operation of your inverter. Refer to the diagrams below for guidance.

5.1 Basic System Architecture

Basic System Architecture diagram for the Sumry Hybrid Solar Inverter
Figure 6: Basic System Architecture, showing the interconnection of solar panels, utility grid, generator, battery, inverter, and home appliances.

The system typically consists of solar panels (PV Input), an optional utility grid or generator (AC Input), a battery bank (for energy storage), the Sumry Hybrid Solar Inverter, and various AC loads (home appliances). An optional WiFi module allows for remote monitoring.

5.2 Wiring and Technical Specifications

Detailed wiring diagram and technical specifications for the Sumry Inverter
Figure 7: Detailed wiring diagram, including connections for AC input, main output, second output, battery, and PV input, along with specific technical parameters.

Important Wiring Notes:

  • AC Input: 110VAC/120VAC, 50/60Hz. Max AC Input Current: 40A/80A. Suggested cable: 12AWG/1.2Nm.
  • PV Input: Max PV Input Power: 4200W. Nominal DC Voltage/Max DC Voltage: 360/500VDC. MPPT Voltage Range: 60-450VDC. Start-up Voltage / Initial Feeding Voltage: 90VDC/120VDC. PV Wire: 12AWG.
  • Battery: Compatible with 24V/48V Lithium/Lead acid batteries. Max Solar Charging Current: 120A. Max AC Charging Current: 100A. Battery Wire: 2AWG. The inverter supports batteryless operation.
  • AC Output: 3600W/6200W. Rate Voltage: 120Vac (100/105/115V settable). Max Main Load: 3600W/6200W. Max Second Load (battery mode): 1200W/2067W. Suggested Cable: 12AWG. Recommended breaker: 32A.
  • Grounding: Always ensure the PE protective conductor is properly grounded.

5.3 Circuit Breaker Installation

Circuit breaker installation knowledge diagram
Figure 8: Diagram illustrating recommended circuit breaker placement for safety and system protection.

Before installing and using the inverter, it is recommended to install 4 circuit breakers in the following positions:

  1. Between the battery pack and the inverter battery input.
  2. Between the solar panel and the photovoltaic input of the inverter.
  3. Between the power input of the grid and the inverter.
  4. Between inverter output and load.

The circuit breaker effectively prevents misconnection or reverse connection of the mains input and the inverter output. In case of a short circuit, load short circuit, or overload in the output, the circuit breaker will cut off the circuit to protect the inverter.

5.4 Battery Compatibility

Battery compatibility types for the Sumry Inverter
Figure 9: The inverter is compatible with various battery types including GEL, LI (Lithium), AGM, USER-defined, and FLD (Flooded) batteries.

The Sumry Hybrid Solar Inverter is compatible with a wide range of 24V/48V batteries, including GEL, Lithium (LI), AGM, User-defined, and Flooded (FLD) types. It also supports a battery-less operation mode, allowing it to power loads directly from the PV array.

5.5 RS485 Communication Line

RS485 communication line connection for lithium batteries
Figure 10: Diagram showing the connection of the RS485 communication line between the inverter's COMM port and a lithium battery's RS485 port.

The RS485 communication line connects the RS485 port of the lithium battery to the COMM port of the inverter. This allows for the export of lithium battery data to the inverter's display screen for easy monitoring. If your lithium battery has a BMS protection board, you may need to purchase a specific 485 communication cable from PACE to ensure compatibility.

6. Operation

6.1 Charging Modes

Sectional Charging and Output source priority diagram
Figure 11: Diagram illustrating the four available charging modes and four output modes.

The inverter offers four distinct charging modes to suit various energy management strategies:

  • Solar First: Prioritizes solar power for charging batteries.
  • Mains First: Prioritizes utility grid power for charging batteries.
  • Hybrid Charge: Uses a combination of solar and mains power for charging.
  • Only Solar: Charges batteries exclusively from solar power.

6.2 Output Modes

The inverter also provides four output modes to manage power delivery to your loads:

  • Solar First: Prioritizes solar power to supply loads.
  • Mains First: Prioritizes utility grid power to supply loads.
  • Inverter First: Prioritizes battery power (via inverter) to supply loads.
  • Hybrid Output: Uses a combination of available power sources for loads.

6.3 Monitoring and Control

Smartess App monitoring and control for Sumry Inverter
Figure 12: The optional WiFi/GPRS module allows for remote monitoring and control via the Smartess App on iOS and Android devices.

With the optional WiFi & GPRS module, you can monitor and control your inverter remotely using the Smartess App, available for both iOS and Android devices. This provides real-time data and system management capabilities.

7. Maintenance

Regular maintenance ensures the longevity and optimal performance of your Sumry Hybrid Solar Inverter.

  • Cleaning: Periodically clean the exterior of the inverter and ensure that the cooling fan vents are free from dust and debris. The intelligent cooling fan system helps manage internal temperatures, but external cleanliness is still important.
  • Connections: Regularly inspect all electrical connections (AC input/output, PV input, battery terminals) for tightness and signs of corrosion. Loose connections can lead to overheating and system malfunction.
  • Environment: Ensure the installation environment remains within the specified operating temperature and humidity ranges.
  • Battery Health: If using batteries, monitor their health and charge levels. Refer to your battery manufacturer's guidelines for specific maintenance procedures.

8. Troubleshooting

The inverter is equipped with multi-functional safety protections to prevent damage. If the inverter is not operating as expected, check the following:

  • No Output Power: Check all input power sources (PV, AC grid, battery) and ensure they are connected and supplying power. Verify that all circuit breakers are in the ON position.
  • Overload Protection: If the inverter shuts down due to overload, reduce the connected load. The inverter will attempt to restart after a cool-down period.
  • Short Circuit Protection: If a short circuit occurs, the inverter will shut down. Identify and resolve the short circuit in the load or wiring before restarting.
  • Battery Issues: Check battery connections and voltage. Ensure the battery type setting in the inverter matches your installed batteries. If operating without batteries, ensure the PV input is sufficient.
  • Overheating: Ensure adequate ventilation around the inverter. Clean any dust from the cooling vents and fans.
  • High/Low Voltage Protection: Verify that input voltages (AC and PV) are within the specified operating ranges.

If problems persist after checking these points, please contact customer support.

9. User Tips

  • Initial Inspection: Upon receiving your inverter, carefully inspect the packaging and contents for any damage. Ensure all components are present before proceeding with installation.
  • Battery Integration: While the inverter can operate without batteries, for full functionality and energy storage, ensure you have compatible 24V/48V batteries (GEL, LI, AGM, USER, FLD types are supported). Plan for battery acquisition if you intend to use them.
  • Wiring Verification: Double-check all wiring connections, especially the polarity for batteries and PV input, to prevent misconnections and ensure safety.
  • App Monitoring: Consider acquiring the optional WiFi/GPRS module to leverage the Smartess App for convenient remote monitoring and control of your system's performance.

10. Warranty and Support

The Sumry 3600W Hybrid Solar Inverter comes with a 1-year warranty. For warranty claims or technical support, please contact your retailer or the manufacturer directly.

1 Year Warranty and certifications for Sumry Inverter
Figure 13: The inverter is backed by a 1-year warranty and holds CE and FC certifications.

Please have your product model number (MPS VIII ECO) and purchase date ready when contacting support.

© 2024 SUMRY. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.