The JUNCTEK JDS8000 series function arbitrary signal generator is a versatile instrument capable of generating sine wave, square wave, triangle wave, pulse wave, arbitrary wave, and other waveforms. It features a frequency range up to 80MHz and includes functions such as modulation, frequency sweep, measurement, and voltage control. The instrument can display the output signal's amplitude, phase, duty cycle, and frequency simultaneously.

Designed with excellent amplitude-frequency characteristics, multi-functionality, high performance, and cost-effectiveness, this portable device is an ideal choice for education, research and development, production, and testing applications. It features a compact design with a 2.8-inch high-resolution color LCD screen for an enhanced visual experience.

Video: Overview of the JDS8000 Series Signal Generator, demonstrating its various functions and physical features.

2. Safety Requirements

Please review the following safety precautions carefully before operating the instrument to prevent personal injury or damage to the instrument and any connected products. Always follow the instructions in this manual for proper use.

  • Use Proper Over-voltage Protection: Ensure no over-voltage (e.g., from lightning) reaches the product to avoid electric shock.
  • Do Not Operate Without Covers: Never operate the instrument with covers or panels removed.
  • Do Not Insert Anything Into the Air Outlet: Avoid inserting objects into the air outlet to prevent damage.
  • Avoid Circuit or Wire Exposure: Do not touch exposed junctions and components when the unit is powered on.
  • Do Not Operate With Suspected Failures: If damage is suspected, have the instrument inspected by JUNCTEK authorized personnel. All maintenance, adjustments, or replacements must be performed by authorized personnel.
  • Provide Adequate Ventilation: Ensure proper ventilation to prevent overheating and damage. Regularly inspect the air outlet.
  • Do Not Operate in Wet Conditions: To avoid short circuits or electric shock, never operate the instrument in a humid environment.
  • Do Not Operate in an Explosive Atmosphere: Never operate the instrument in an explosive atmosphere to prevent personal injury or damage.
  • Prevent Electrostatic Impact: Operate in an electrostatic discharge protective environment. Always ground internal and external cable conductors to release static before making connections.

3. Setup and Inspection

3.1 Inspect the Packaging

If the packaging is damaged, do not discard it until the shipment has been checked for completeness and passed electrical and mechanical tests. Damage during shipment is the responsibility of the consignor or carrier. We are not responsible for free maintenance, rework, or replacement due to shipping damage.

3.2 Check the Contents

Verify the contents against the packing list. If any items are damaged or missing, contact your JUNCTEK sales representative immediately.

Packing List
Item Description Quantity
Host JDS8000 arbitrary function signal generator 1 pc
Power cord 1 pc
USB cable 1 pc
Accessory BNC to alligator clips test lead 2 pcs
BNC male plug test lead 1 pc
Certificate of conformity 1 pc
Quick guide 1 pc
JDS8000 Signal Generator and included accessories: power cord, USB cable, BNC to alligator clips test leads, BNC male plug test lead, certificate, and quick guide.
Image: JDS8000 Signal Generator with its complete set of accessories.

3.3 Inspect the Instrument

In case of any mechanical damage, missing parts, or failure in passing electrical and mechanical tests, contact your JUNCTEK sales representative.

3.4 Power On and Language Selection

The JDS8000 series can be powered by two methods:

  • AC Power: Connect the provided power cord to the signal generator. Input voltage: AC 85-264V, 47-63Hz.
  • DC Power: Alternatively, it can be powered by a DC5V±0.5V 3A power adapter.

After connecting the power supply, press the power key on the front panel. The instrument will perform initialization and self-test. If it does not start normally, refer to the Troubleshooting section.

Upon booting, you can select the system language (English or Chinese) using the corresponding soft key. The selected language will be remembered for subsequent power-ons.

4. Operating Instructions

4.1 Instrument Overview

The JDS8000 series features a user-friendly interface with a 2.8-inch color screen and intuitive controls.

Front panel of JDS8000 Signal Generator with labels for 2.8 inch color screen, function shortcut keys, knob, direction keys, channel control keys, switch, function soft keys, input interface, and output interface.
Image: Front Panel Overview of the JDS8000 Signal Generator.

Front Panel Components:

  • Power Switch (1): Turns the generator on/off.
  • Channel Control Keypad (2): Includes CH1 and CH2 buttons to enable/disable output for each channel. The OUT button controls both simultaneously.
  • Signal Input Connector (3): EXT.IN for external signals (1Vpp-20Vpp) and MOD.IN for modulation input (0Vpp-3Vpp).
  • Signal Output Connectors (4): CH1 and CH2 BNC connectors ($50Ω ±10%$ nominal impedance) for waveform output.
  • Arrow Keys (5): Used to navigate menus, select digits for editing, and delete values.
  • Knob (6): Adjusts parameter values (clockwise for increase, counter-clockwise for decrease) and quickly switches waveforms.
  • Function Shortcut Keys (7): Numeric keys (0-9), decimal point (.), and sign key (+/-) for parameter input.
  • Function Soft Keys (8): Activates corresponding menus displayed on the right side of the screen.
  • LCD (9): 2.8-inch TFT color display for menus and parameter settings.
  • MEM Key (10): Loads or saves instrument parameters.
  • InBox Key: Opens a pop-up window for direct numerical input.
  • SHIFT Key: Provides help information for keys or soft keys.
Rear panel of JDS8000 Signal Generator with labels for ground terminal, vents, extended interface, communication interface, DC power socket, AC power socket, and power switch.
Image: Rear Panel Overview of the JDS8000 Signal Generator.

Rear Panel Components:

  • Sync Connectors (1): Allows synchronization with other JDS8000 series instruments.
  • Extension Interfaces (2): Serial port with TTL level for secondary development. Includes GPI (Digital signal input interface) and GPO1 (Digital signal output interface 1).
  • USB Interface (3): Connects to a computer for remote control via PC software or programming.
  • DC Power Socket (4): DC5V±0.5V 3A input.
  • AC Power Socket (5): AC 85-264V, 47-63Hz input, max 30W. Fuse: 250V, T3.15A.
  • Switch (6): Turns the signal generator on or off.
  • Cooling Holes (7): Dissipate heat.
  • Chassis Ground (8): Connects to ground for safety and proper electrical system operation.

4.2 Outputting Basic Waveforms

The JDS8000 can output basic waveforms (Sine, Square, Triangle, Pulse) from one or both channels simultaneously. By default, dual channels output a sine waveform at 10kHz frequency and 5Vpp amplitude.

Steps to Output a Basic Waveform:

  1. Select Output Channel: Press the CH1 or CH2 button to select the desired channel. The active channel's text on the display will be white.
  2. Select Waveform: Press the WAVE soft key. Use the knob or soft keys to choose the desired waveform (e.g., Sine, Square, Triangle, Pulse).
  3. Set Frequency: Press the Freq soft key. Use arrow keys and the knob to adjust the frequency, or press InBox for direct input.
  4. Set Amplitude: Press the Ampl soft key. Adjust amplitude using arrow keys/knob or InBox. Note that amplitude range is frequency-dependent.
  5. Set Offset: Press the Offset soft key. Adjust DC offset using arrow keys/knob or InBox.
  6. Set Duty Cycle: Press the Duty soft key (for pulse/bias sine waveforms). Adjust duty cycle using arrow keys/knob or InBox.
  7. Set Phase: Press the Phase soft key. Adjust phase difference using arrow keys/knob or InBox. Ensure frequency synchronization is set in system settings before adjusting phase difference between channels.
  8. Observe Output: Connect CH1 and CH2 to an oscilloscope using BNC cables to observe the generated waveforms.

4.3 Modulation Mode

The JDS8000 series supports various modulation types including AM, FM, PM, ASK, FSK, PSK, Pulse, and Burst. Modulation processes a signal by adding it to a carrier wave for transmission.

General Modulation Steps:

  1. Press the MOD key to enter the modulation interface.
  2. Press the Type soft key and use the knob or direction keys to select the desired modulation type (AM, FM, PM, ASK, FSK, PSK, Pulse, Burst).
  3. Select Carrier Waveform: Refer to the specific modulation type for compatible carrier waveforms. Generally, sine, square, ramp, and arbitrary waveforms are supported (DC, pulse, noise, and some arbitrary waveforms may be excluded).
  4. Select Source: Press Signal Source to choose between "Internal" or "External" modulation source. External modulation uses the MOD connector on the front panel.
  5. Set Modulation Parameters: Adjust parameters like modulation frequency (Mod.F), depth (Depth), frequency deviation (F.Dev), phase deviation (P.Dev), rate (Rate), ASK amplitude, hopping frequency (Hop.F), pulse width (Width), pulse period (Period), idle mode (Idle), and trigger source (T.Src) as applicable for the selected modulation type. Use InBox for direct input.

4.4 Sweep Mode

The sweep function allows for frequency, amplitude, or duty cycle sweeping. It supports linear and logarithmic sweep modes, and increment, decrement, or round trip directions.

Steps to Configure Sweep:

  1. Press the SWEEP key to enter the sweep frequency interface.
  2. Press the Func soft key to select the sweep type: Frequency Sweep, Amplitude Sweep, or Duty Cycle Sweep.
  3. Sweep Channel: Use the knob to select CH1 or CH2.
  4. Start/Stop Parameters: Set the start and stop frequency, amplitude, or duty cycle.
  5. Sweep Time: Adjust the sweep duration (0.01s to 640s).
  6. Sweep Direction: Choose between increment, decrement, or round trip.
  7. Sweep Mode: Select linear or logarithmic.
  8. Activate Sweep: Press the ON soft key to start the sweep.

4.5 Voltage Control Mode (VCO)

The VCO function allows external voltage signals to control the frequency, amplitude, or duty cycle of the output waveform.

Steps to Configure VCO:

  1. Press the VCO key to enter the voltage control interface.
  2. Press the Func soft key to select the control type: Frequency Control, Amplitude Control, or Duty Cycle Control.
  3. Voltage Control Channel: Use the knob to select CH1 or CH2.
  4. Start/Stop Parameters: Set the start and stop frequency, amplitude, or duty cycle.
  5. Voltage Calibration: Calibrate the minimum and maximum external input signal voltages (0V-5V). The minimum voltage corresponds to the start parameter, and the maximum to the stop parameter.
  6. Voltage Control Mode: Select linear or logarithmic.
  7. Activate VCO: Press the ON soft key to enable voltage control.

4.6 Measurement Mode

The JDS8000 includes a built-in 1Hz-100MHz frequency meter and counter.

Steps to Use Measurement Function:

  1. Press the MEAS key to enter the measurement interface.
  2. Press the Cnt or Meas soft keys to switch between measurement and counter functions.
  3. Measurement Function: Measures frequency, period, positive/negative pulse width, and duty cycle of input signals (1Hz-100MHz, 2Vpp-20Vpp input signal amplitude range via Ext.IN).
  4. Coupling Settings: Press the soft key to select AC or DC coupling.
  5. Gate Time: Set the measurement gate time (0.001s to 10s, default 1s).
  6. Measurement Mode: Select low frequency (<2kHz) or high frequency (>2kHz).
  7. Counter Function: Calculates the number of periods of the input signal in real-time (2Vpp-20Vpp input signal amplitude range).

4.7 System Settings

The system settings allow customization of various instrument parameters.

Steps to Access System Settings:

  1. Press the SYS button to enter the system setting interface.
  2. Use the arrow keys or PgDn soft key to navigate through settings.
  3. Clear Memory: Clears stored parameters.
  4. Sound Setting: Turns sound on/off.
  5. Brightness Adjustment: Adjusts LCD screen brightness.
  6. Language Setting: Selects English or Chinese.
  7. Built-in Waveforms: Sets the number of built-in waves (00-21).
  8. Arbitrary Waveforms: Sets the number of arbitrary waves (01-99).
  9. Waveform Loading Mode: Selects Auto or Fast loading.
  10. System Information: Displays product model, serial number, hardware/firmware/FPGA versions.
  11. Waveform Synchronization: Turns CH1/CH2 waveform synchronization on/off.
  12. Frequency Synchronization: Turns frequency synchronization on/off.
  13. Amplitude Synchronization: Turns amplitude synchronization on/off.
  14. Offset Synchronization: Turns offset synchronization on/off.
  15. Duty Cycle Synchronization: Turns duty cycle synchronization on/off.
  16. External Synchronization: Turns external synchronization on/off.
  17. Restoring Factory Settings: Resets all settings to factory defaults.
  18. Auto Power On: Enables/disables automatic power-on output.
  19. CH1/CH2 Amplitude Fine-adjusting: Calibrates output amplitude for accuracy.

4.8 Mobile App Control (Android & iOS)

The JDS8000 series features a built-in Bluetooth chip for wireless remote control and arbitrary waveform drawing via a mobile app.

App Installation and Connection:

  • Android App: Download from the provided server link: JDS8000.apk. Ensure Android 5.0 or above and grant location service permission.
  • iOS App: Search for "jds8000 series signal generator" in the Apple App Store. Requires iOS 9.0 or above and Bluetooth access permission.
  • Connection: On the app's home screen, click search to find and connect to the instrument's Bluetooth. The app will indicate "connected" and display the machine model.
  • Software Update: The app will automatically detect and prompt for updates. Google Play versions may require manual updates.

The app interface mirrors the instrument's display, allowing control over main functions, modulation, sweep, measurement, and system settings. It also supports arbitrary waveform editing and drawing.

Screenshot of PC software interface for arbitrary waveform drawing, showing waveform editing tools and output display.
Image: PC software interface for arbitrary waveform drawing.

5. Maintenance

5.1 Handle with Caution

During transportation, handle the instrument with care to prevent damage to keys, knobs, interfaces, and other panel parts. The shell is fragile and susceptible to corrosion; avoid hitting it or exposing it to chemicals.

5.2 Environmental Conditions

  • Working Temperature: -10°C to 50°C
  • Storage Temperature: -20°C to 70°C
  • Keep the instrument in a dry environment.

5.3 General Care

  • Do not attempt to disassemble the instrument; this will void the warranty. Repairs must be performed by authorized personnel.
  • Avoid placing unsafe items (e.g., lighted candles, cups of water, corrosive chemicals) on the instrument's surface.
  • The display screen is fragile. Do not touch or bump it. Clean the LCD surface with a soft cloth if dirty.
  • Do not move the instrument violently to prevent internal circuit damage.
  • Keep instrument surfaces clean and dry to prevent dust or moisture from affecting performance.

6. Troubleshooting

If you encounter any issues, follow these steps. If the problem persists, contact JUNCTEK support.

6.1 No Display After Power Key Press

  1. Check if the power connector is properly connected.
  2. Verify the power key is functioning.
  3. Restart the instrument after checking the above.
  4. If the issue persists, contact JUNCTEK.

6.2 Screen Too Dark

  1. Check the brightness setting of the LCD screen.
  2. Press the SYS key to enter the system setting menu. Navigate to brightness and adjust the knob to the desired level.

6.3 Correct Settings, No Waveform Output

  1. Check if the BNC cord is correctly connected to the corresponding CH1 or CH2 channel output connectors.
  2. Inspect the BNC cord for internal damage.
  3. Ensure the BNC cord is securely connected to the instrument.
  4. Check if the indicator above the signal output connectors CH1 or CH2 is lit.
  5. If not lit, press the corresponding key to turn it on.
  6. Restart the instrument after completing the above inspections.
  7. If the issue persists, contact JUNCTEK.

7. Specifications

7.1 Frequency Characteristics

Characteristic JDS8060 JDS8080
Sine waveform frequency range 1nHz~60MHz 1nHz~80MHz
Square waveform frequency range 1nHz~15MHz 1nHz~15MHz
Triangle waveform frequency range 1nHz~15MHz 1nHz~15MHz
Pulse waveform frequency range 1nHz~10MHz 1nHz~10MHz
TTL digital waveform frequency range 1nHz~6MHz 1nHz~6MHz
Arbitrary waveform frequency range 1nHz~6MHz 1nHz~6MHz
Pulse width adjustment range 20nS~4S 20nS~4S
Rise time ≤20ns ≤10ns
Fall time ≤20ns ≤10ns
Frequency minimum resolution 1nHz (0.000000001Hz)
Frequency accuracy ±5ppm 0 to 50°C
Frequency stability ±3ppm per 1 year

7.2 Waveform Characteristics

Characteristic Value
Waveform type Sine, square, triangle, pulse (duty cycle adjustable, pulse width and cycle time precisely adjustable), ramp, CMOS, DC level, partial sine, half wave, full wave, positive/anti ladder, noise, exponential rise/drop, logarithmic rise/drop, cinker pulse, multi audio wave Lorentz pulse, and 99 user-defined waveforms.
Wave length 8192 points/channel
Sampling rate 275MSa/S
Waveform vertical resolution 14 bits
Harmonic suppression ≥45dBc(<1MHz); ≥40dBc(1MHz~20MHz)
Total harmonic distortion <1%(20Hz~20kHz,0dBm)
Square wave and pulse wave overshoot ≤5%
Duty cycle adjustment range 0.01%~99.99%
Sawtooth waveform linearity ≥98% (0.01Hz-10kHz)

7.3 Output Characteristics

Characteristic Value
Amplitude range of sine waveform Frequency <1MHz: 2mVpp~25Vpp
1MHz≤Frequency<11MHz: 2mVpp~20Vpp
11MHz≤Frequency<31MHz: 2mVpp~10Vpp
31MHz≤Frequency<61MHz: 2mVpp~5Vpp
61MHz≤Frequency≤80MHz: 2mVpp~3.6Vpp
Amplitude range of square/triangle waveforms Frequency <1MHz: 2mVpp~25Vpp
1MHz≤Frequency<11MHz: 2mVpp~20Vpp
1MHz≤Frequency≤15MHz: 2mVpp~10Vpp
Amplitude resolution 1mVpp
Amplitude stability ±1%±1mVpp (@1kHz, >10mVpp)
Amplitude flatness ±1%(0.1dB)<10MHz
±2%(0.2dB)<10MHz~50MHz
±10%(0.9dB)<50MHz~70MHz
Impedance 50Ω±10% (typical)
Protection All signal outputs can be on within 60s under load short circuit

7.4 DC Offset

Characteristic Value
Adjustment range -9.99V~12.00V
Resolution 0.01 V

7.5 Phase Characteristics

Characteristic Value
Adjustment range 0~359.99°
Resolution 0.01°

7.6 Measurement and Counter Function

Characteristic Value
Measurement function Frequency, positive/negative pulse width, period, duty cycle
Coupling method DC, AC
Gate time 0.001S~10.000S
Measurement mode Low frequency, high frequency
Frequency measurement range 1Hz~100MHz
Input signal amplitude range 1Vpp~20Vpp
Period measurement 10nS~4S
Pulse Width 4S
Duty cycle measurement range 0.01%~99.99%
Counter range 0-4294967295
Counter coupling method DC and AC
Counter method Manual

7.7 Modulation Characteristics

Modulation Type Characteristic Value
AM Depth 0% to 200%
Modulation frequency 1mHz to 1MHz
Carrier waveform Sine, square, ramp, arbitrary (except DC)
Modulation waveform Sine, square, ramp, noise, arbitrary
FM Modulation frequency 1mHz to 1MHz
Frequency deviation 0.1Hz to 10kHz
Carrier waveform Sine, square, ramp, arbitrary (except DC)
PM Phase deviation 0° to 360°
Modulation frequency 1mHz to 1MHz
Carrier waveform Sine, square, ramp, arbitrary (except DC)
ASK Rate 1mHz to 1MHz
ASK amplitude 0% to 200%
Carrier waveform Sine, square, ramp, arbitrary (except DC)
FSK Rate 1mHz to 1MHz
Frequency hopping 0.1Hz to 80MHz
Carrier waveform Sine, square, ramp, arbitrary (except DC)
PSK Rate 1mHz to 1MHz
PSK phase 0° to 360°
Carrier waveform Sine, square, ramp, arbitrary (except DC)
PWM Pulse period 0.02uS to 40S
Pulse Width 0.020uS to 4S
Carrier waveform Pulse
Burst Pulse number 1-1048575
Idle Zero position, positive maximum, negative maximum
Mode Single, automatic
Trigger source Manual, CH2 burst, external (AC), external (DC)

7.8 External Modulation Input Characteristics

Characteristic Value
Input signal amplitude range 0~3Vpp
Input signal frequency range 20Hz~20kHz

7.9 Sweep Characteristics

Characteristic Value
Sweep channel CH1 or CH2
Carrier waveform Sine, square, ramp, arbitrary (except DC)
Sweep function Sweep frequency, sweep amplitude, sweep duty
Sweep mode Linear, logarithmic
Sweep direction Increment, decrement, round trip
Start/stop frequency Consistent with the upper and lower limits of the corresponding carrier frequency
Start/stop amplitude Consistent with the upper and lower limits of the corresponding carrier amplitude
Start/stop duty cycle Consistent with the upper and lower limits of the corresponding carrier duty cycle
Sweep time 0.01S-640S

7.10 Voltage Control Characteristics

Characteristic Value
Voltage control channel CH1 or CH2
Carrier wave Sine, square, ramp, arbitrary (except DC)
Voltage control function Frequency control, amplitude control, and duty cycle control
Sweep mode Linear, logarithmic
Start/stop frequency Consistent with the upper and lower limits of the corresponding carrier frequency
Start/stop amplitude Consistent with the upper and lower limits of the corresponding carrier amplitude
Start/stop duty cycle Consistent with the upper and lower limits of the corresponding carrier duty cycle
Voltage control voltage range 0V-5V, start point and stop point can be set arbitrarily

7.11 General Parameters

Characteristic Value
Display screen 2.8 inch TFT color LCD screen
Store and load quantity 100 groups
Store and load location 00 to 99 (data of 00 storage location is loaded by default)
Interface method USB to serial interface
Extension interface Serial port with TTL level, convenient for secondary development
Communication rate Standard 115200bps
Protocol Using the command line, the protocol is open.

7.12 Power and Environment

Characteristic Value
AC power supply voltage 85V-264V, 47-63Hz
AC power consumption <30W
Fuse 250VAC, T3.15A
DC power voltage/current DC5V±0.5V 3A
Operating temperature -10°C~50°C
Humidity <80%

8. User Tips

  • For precise pulse width adjustments, utilize the dedicated pulse width modulation function rather than just the duty cycle setting.
  • When using the mobile app, ensure your device's Bluetooth is enabled and location services are granted for proper connection.
  • Always use appropriate BNC cables and ensure secure connections for accurate waveform observation on an oscilloscope.
  • Take advantage of the PC software for complex arbitrary waveform drawing and editing, which can then be easily uploaded to the generator.

9. Warranty and Support

9.1 Warranty Conditions

The instrument comes with a one-year warranty from the date of shipment. During this period, Hangzhou Junce Instruments Co., Ltd. will repair or replace faulty instruments as needed. For maintenance, please contact our after-sales service.

Conditions Not Covered by Warranty:

  • Improper operation or maintenance by the user.
  • Use of user-provided software or power interface.
  • Disassembly and repair of the instrument without permission.

9.2 Contact Us

For any problems or requirements regarding our products or this manual, please contact JUNCTEK:

Additional resources, including operation videos, PC software, communication protocols, and detailed user manuals, are available on the JUNCTEK official website.

A user manual in PDF format is also available for download: JDS8000 Series User Manual (PDF).

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.