1. Introduction
This manual provides essential information for the safe and efficient use of your LISHEN 20Ah 3.2V LiFePO4 Prismatic Battery Cell. Please read this manual thoroughly before installation and operation to ensure optimal performance and longevity of the battery.
2. Safety Information
⚠ WARNING: KEEP OUT OF REACH OF CHILDREN
In case of ingestion, seek medical attention immediately.
Always handle battery cells with care. Improper handling can lead to injury or damage to the battery.
2.1 General Safety Guidelines
- Do not short-circuit the battery terminals.
- Do not expose the battery to extreme temperatures (above 60°C or below -20°C for discharge, below 0°C for charge).
- Do not immerse the battery in water or other liquids.
- Do not disassemble, crush, puncture, or modify the battery.
- Use only compatible charging equipment.
- Ensure proper ventilation when charging or discharging.
2.2 Safety Performance
The LISHEN LiFePO4 battery cells have undergone rigorous safety testing, demonstrating robust performance under various conditions:
| Test Type | Result |
|---|---|
| Over-discharge test | No exshaion, no fire, no leakage |
| Drop test | No exshaion, no fire, no leakage |
| Temperature cycling test | No exshaion, no fire, no leakage |
| Low pressure test | No exshaion, no fire, no leakage |
| Overcharge test | No exshaion, no fire |
| Short circuit test | No exshaion, no fire |
| Heating test | No exshaion, no fire |
| Squeeze test | No exshaion, no fire |
| Sea water immersion test | No exshaion, no fire |
3. Product Overview
The LISHEN 20Ah 3.2V LiFePO4 Prismatic Battery Cell is a high-performance lithium iron phosphate battery designed for various energy storage and power applications. Its prismatic design offers efficient space utilization, and its robust construction ensures reliability.
3.1 Key Features
- Safe Chemical Composition: Utilizes LiFePO4 chemistry, known for its inherent safety and stability, with no high-concerned chemicals.
- Prismatic Design: Offers an optimized form factor for compact integration into various systems.
- High Capacity: Provides a nominal capacity of 20Ah, suitable for demanding applications.
- High Rate Discharge: Capable of rapid power delivery, making it ideal for applications requiring quick energy release.
- Long Cycle Life: Designed for 6000+ cycles, ensuring extended operational life.
- Maintenance-Free: Requires no regular maintenance, reducing operational hassle.
3.2 Wide Applications
This battery cell is suitable for a broad range of applications, including but not limited to:
- E-bikes and Light Electric Vehicles (LEV)
- Electric Forklifts
- Uninterruptible Power Supplies (UPS)
- Motor Homes and RVs
- Solar Power Systems
- Wind Power Systems
- Home Power Reserves
- Communication Reserve Power
- Electric Buses and Cars
- DIY Battery Packs
4. Specifications
Detailed technical specifications for the LISHEN 3.2V 20Ah LiFePO4 Prismatic Battery Cell:
| No. | Item | Value |
|---|---|---|
| 1 | Model Number | LISHEN 3.2V 20Ah |
| 2 | Battery Type | LiFePO4/Lithium Battery |
| 3 | Nominal Voltage | 3.2V |
| 4 | Nominal Capacity | 20Ah |
| 5 | Net Weight of cell | 514±10g |
| 6 | Dimension (not include the studs) | 70*133.5*27-29mm |
| 7 | Nominal Energy | 64 Wh |
| 8 | Cycle Life | 5000+ Cycles |
| 9 | Charge voltage | 3.65±0.05V |
| 10 | Cut-off voltage | 2.0±0.05V |
| 11 | Battery internal resistance (1KHz) | <6mΩ |
| 12 | Standard charging current | 0.5C |
| 13 | Standard discharge current | 0.5C |
| 14 | Max. Charge Current | 1C |
| 15 | Max. Continuous Discharge Current | 1C |
| 16 | Max Pulse Discharging Current | 2C |
| 17 | Monthly self-discharge | <3.5% |
| 18 | Charging Temperature | 0~60°C |
| 19 | Discharging Temperature | -20~60°C |
| 20 | Storage Temperature | -20°C~45°C |
For a comprehensive user manual in PDF format, please refer to the official document: LISHEN 3.2V 20Ah LiFePO4 Battery Cell User Manual (PDF).
5. Setup and Installation
Proper setup is crucial for the performance and safety of your battery cells. These are general guidelines; specific application requirements may vary.
5.1 Pre-Installation Checks
- Inspect each battery cell for any physical damage (e.g., dents, leaks, swollen casing). Do not use damaged cells.
- Verify the voltage of each cell before connecting them in series or parallel. Cells should be within a close voltage range.
- Ensure all connection points are clean and free from corrosion.
5.2 Connection Guidelines
- When connecting multiple cells, use appropriate busbars or cables that can handle the expected current.
- For series connections, connect the positive terminal of one cell to the negative terminal of the next. This increases the total voltage.
- For parallel connections, connect positive to positive and negative to negative. This increases the total capacity.
- Always use a Battery Management System (BMS) for multi-cell configurations to monitor voltage, current, and temperature, and to provide balancing and protection.
- Tighten all connections securely to prevent loose contacts, which can cause resistance and heat buildup.
5.3 Environmental Considerations
- Install the battery in a well-ventilated area, away from direct sunlight, heat sources, and flammable materials.
- Ensure the operating temperature remains within the specified range (Charging: 0~60°C; Discharging: -20~60°C).
6. Operating Instructions
6.1 Charging
- Use a charger specifically designed for LiFePO4 batteries with the correct voltage and current settings.
- The recommended charge voltage is 3.65V ± 0.05V per cell.
- Standard charging current is 0.5C (10A for a 20Ah cell). The maximum charge current is 1C (20A for a 20Ah cell).
- Do not overcharge the battery. A BMS will help prevent this.
- Charging temperature should be between 0°C and 60°C.
6.2 Discharging
- The nominal voltage is 3.2V per cell.
- The cut-off voltage is 2.0V ± 0.05V per cell. Do not discharge below this voltage to prevent damage. A BMS is essential for this protection.
- Standard discharge current is 0.5C (10A for a 20Ah cell).
- Maximum continuous discharge current is 1C (20A for a 20Ah cell).
- Maximum pulse discharging current is 2C (40A for a 20Ah cell).
- Discharging temperature should be between -20°C and 60°C.
7. Maintenance
LiFePO4 batteries are generally maintenance-free, but following these guidelines will help prolong their lifespan:
- Regular Inspection: Periodically check the battery cells and connections for any signs of damage, corrosion, or loose terminals.
- Cleaning: Keep the battery terminals and surfaces clean and dry. Use a dry cloth to wipe off any dust or dirt.
- Storage: If storing the battery for an extended period, ensure it is charged to approximately 50% of its capacity (around 3.2V-3.3V per cell). Store in a cool, dry place with a storage temperature between -20°C and 45°C.
- Avoid Deep Discharge: While LiFePO4 batteries tolerate deep discharge better than other chemistries, consistently avoiding discharge below the cut-off voltage will maximize cycle life.
- Cell Balancing: For multi-cell packs, ensure your Battery Management System (BMS) is actively balancing the cells to maintain voltage consistency.
8. Troubleshooting
This section addresses common issues you might encounter. Always prioritize safety when troubleshooting.
8.1 Battery Not Charging
- Check Connections: Ensure all charging cables are securely connected to the battery and charger.
- Verify Charger: Confirm the charger is functioning correctly and is compatible with LiFePO4 batteries.
- Temperature: Ensure the charging temperature is within the specified range (0°C to 60°C).
- BMS Protection: If a BMS is installed, it might have triggered a protection mode (e.g., over-discharge protection). Check the BMS status.
8.2 Low Voltage Output
- State of Charge: The battery might be deeply discharged. Attempt to charge it.
- Load: The connected load might be too high, causing voltage sag. Reduce the load or check for short circuits.
- Connections: Loose or corroded connections can cause voltage drops. Inspect and clean terminals.
- Cell Imbalance: In multi-cell packs, an imbalanced cell could be causing the overall pack voltage to drop prematurely. Check individual cell voltages with a multimeter.
8.3 Excessive Heat During Operation
- Overload: The battery might be subjected to currents exceeding its maximum continuous discharge current. Reduce the load.
- Internal Resistance: High internal resistance can lead to heat generation. This might indicate a faulty cell or an aging battery.
- Ventilation: Ensure adequate airflow around the battery to dissipate heat.
9. User Tips
While specific user reviews or Q&A were not provided, here are some general tips for maximizing the performance and lifespan of your LiFePO4 battery cells:
- Initial Charge: It's often recommended to fully charge new cells before their first use to ensure they are balanced and ready for operation.
- BMS is Key: For any multi-cell battery pack, a reliable Battery Management System (BMS) is indispensable for safety, balancing, and overall longevity.
- Parallel First, Then Series: When building a large battery pack, it's often advised to parallel cells first to balance them, then connect the parallel groups in series.
- Temperature Management: Avoid operating or storing the batteries at the extreme ends of their temperature ranges for prolonged periods. Moderate temperatures contribute to better performance and lifespan.
10. Warranty and Support