Gaqqee KWS-X1 Type C Tester

Contents

Gaqqee KWS-X1 Type C Tester User Manual

Model: KWS-X1 Type C Tester

1. Introduction

The Gaqqee KWS-X1 Type C Tester is a highly reliable and safe voltage and current testing meter designed for mobile communication terminals. It features a CNC metal case for durability, an HD IPS display, and supports real-time charging power detection. This multi-functional device is capable of curve measurement, ripple measurement, and comprehensive protocol testing for various fast charging standards.

It is fully compatible with fast charging protocols such as PD (Power Delivery) and Qualcomm QC3.0/4.0, and supports a wide range of other protocols including PD/QC2.0/3.0/4.0 and MTK.

KWS-X1 Type C Tester main display showing voltage, current, power, and protocol detection

Figure 1: KWS-X1 Type C Tester main display

2. Package Contents

  • KWS-X1 Type C Tester x 1

3. Product Overview

3.1 Physical Features

The KWS-X1 Type C Tester features a compact design with an aluminium metal housing, making it dust-proof and drop-proof. It is equipped with an HD IPS display for clear readings.

KWS-X1 Type C Tester with aluminium metal housing

Figure 2: KWS-X1 Type C Tester highlighting metal housing

3.2 Dimensions

The device measures 54.96mm in length, 24.45mm in width, and 11.15mm in thickness.

Product size diagram of KWS-X1 Type C Tester

Figure 3: Product Dimensions

3.3 Buttons

With the screen facing forward, the buttons from left to right are: (Back), (Confirm), (-), (+).

Back view of KWS-X1 Type C Tester showing model, voltage, current, and protocol support

Figure 4: Back view of the tester with model information

4. Setup

To begin using the KWS-X1 Type C Tester, simply connect it inline with your Type-C charging setup. Plug the male Type-C connector into your power source (charger, power bank, etc.) and connect your device (phone, tablet, etc.) to the female Type-C port on the tester. The device will power on automatically and display real-time measurement data.

5. Operating Instructions

5.1 Menu Navigation

To access the main menu, long press the (Back) button from the "Home - Measurement" screen. Options in the menu are distinguished by deep and light colors; deep color indicates unselected, while light color indicates the currently active option. Use the (+/-) buttons to select options and the (Confirm) button to enter. To exit an option's specific page and return to the menu, press the (Back) button.

Menu - Home Page display on KWS-X1 Type C Tester

Figure 5: Main Menu - Home Page

5.2 Home - Measurement

This screen provides real-time display of voltage, current, and power measurements. It also shows the handshake protocol name (e.g., PD protocol gear or current QC gear) and real-time data IO DP DN CC1 CC2 bus voltage, with automatic highlighting of the IO used in protocol transmission over CC pins. The current direction indicator light changes color based on power level (green for lower power, purple for higher power).

Home - Measurement screen showing real-time voltage, current, power, and protocol information

Figure 6: Home - Measurement Screen

5.3 Home - Statistical Information

This screen displays real-time voltage, current, and power, along with the real-time protocol status. It includes capacity statistics (which supports offline power-off saving and can be reset by long pressing the (Confirm) button), statistics for maximum current, voltage, and power, and the MCU on-chip temperature sensor reading.

Home - Statistical Information screen showing various measurement statistics

Figure 7: Home - Statistical Information Screen

5.4 Menu - Ripple Measurement

This mode allows for ripple measurement. It shows the status (real-time or paused measurement, toggled with Confirm button), sampling speed (adjustable with +/-), a drawing curve area, real-time voltage and current (supports pausing), and real-time display of average ripple within 100ms, tracking VBUS voltage changes.

Ripple Measurement screen displaying a waveform

Figure 8: Menu - Ripple Measurement Screen

5.5 Menu - Curve Measurement

In this mode, the per-grid voltage in area 4 adapts automatically to the total voltage. It displays the sampling time (total time of the displayed section, adjustable with +/-), current direction indication (updates flow rate based on current magnitude), real-time drawing of curves, and real-time display of voltage, current, and power.

Curve Measurement screen displaying voltage and current curves

Figure 9: Menu - Curve Measurement Screen

5.6 Menu - Settings

The settings menu allows configuration of various device parameters:

  • Language Selection: Choose between Chinese and English.
  • Screen Saver Timing: Configure the screen saver, including an 'always on' option.
  • Screen Brightness Adjustment: The brightness adjustment uses a logarithmic curve, similar to commercial displays, meaning the percentage adjusted is not linear.
  • Gravity Sensing: Enable or disable gravity sensing for UI display rotation.
Settings screen showing language, screen saver, brightness, and gravity sensing options

Figure 10: Menu - Settings Screen

5.7 Menu - Protocol Test - Entry

This interface allows you to trigger fast charging protocols. When activated, it can trigger the corresponding proprietary protocol or simulate brand information. The purpose is to obtain the maximum test gear when deceiving with a male plug without a data connection, or to use a mother socket deception with a non-chip data cable to achieve the maximum gear. Note that simulated information may exceed the actual current carrying capacity of the data cable.

To trigger the default tab, use (+/-) to switch and (Confirm) to select. For Emarker simulation, the dip switch needs to be set to deception mode, not pass-through mode.

Protocol Test Interface showing options for EMarker and protocol testing

Figure 11: Menu - Protocol Test - Entry Screen

5.8 Menu - Protocol Test - Automatic Test

This mode performs an automatic test of charging protocols. Green indicates support, red indicates no support.

  • Status Indicator: Waits for automatic operation to complete.
  • PD Status Indicator: Includes PD2.0-3.1 Fixed AVS EPR.
  • Maximum PDO Gear and Power Display.
  • PPS Support: Displays support for PPS and maximum adjustable PPS gear power.
  • Fixed Gear Support: Shows supported voltages for Fixed gear, and the number and range of adjustable PDO voltages.
  • QC2.0 Fixed Gear Support Status.
  • QC3.0 Adjustable Gear: Displays maximum trigger voltage, with steps of 200mV.
  • PD Protocol Version Indicator: Special protocols (e.g., Xiaomi's private) will show specific information.
Auto Protocol Detection Interface showing various fast charging protocols detected

Figure 12: Menu - Protocol Test - Automatic Test Screen

5.9 Menu - Protocol Test - PD Single Deception

In this mode, the selected gear will not trigger immediately. You must press the (Confirm) button again to confirm the deception, which will then be displayed at the top and the operation executed. Display colors (red + green) follow this logic.

  • Detailed Protocol Version and Number of Gears: Typically highlights PDOs that support AVS EPR extensions.
  • Current Gear Display.
  • Real-time Current.
  • Current Direction.
  • Supported Gear Listing: Intervals automatically merge if exceeding maximum displayable amount.
  • Selected Gear Information.
Individual decoys screen showing detailed protocol version and gear information

Figure 13: Menu - Protocol Test - PD Single Deception Screen

5.10 Menu - Protocol Test - PD Single Deception - PPS

This interface is accessed after selecting the PPS gear in "Protocol Test - PD - Single Deception". The adjustment logic here is real-time and does not require confirmation. The voltage adjustment panel is divided into voltage and current settings. A white underline in a red solid frame represents the selected cursor.

5.11 Menu - Protocol Test - QC

This section covers QC protocol testing:

  • QC2.0: Has fixed gears. Status information displays DP DN handshake voltage. Protocol voltage selection uses the (+/-) selection logic, confirmed with the (Confirm) button.
  • QC3.0/QC4+: Supports 200mV step adjustment (0.2V minimum adjustment unit). Status information displays DP DN handshake voltage. QC protocol voltage adjustment panel uses the same grey depth for (+/-) selection logic, confirmed with the (Confirm) button.
Voltage and current display showing QC3.0 with adjustable voltage

Figure 14: Menu - Protocol Test - QC Screen

6. Specifications

NOTE: Normal and stable use should not exceed the typical recommended values for extended periods.

Parameter Minimum Value Typical Value Maximum Value
Absolute Withstand Voltage0.0V-40.0V
Absolute Current0.0A-16.0A
Absolute Power0.0W0.0-140.0W240.0W
Measured Voltage3.3V3.3-30.0V40.0V
Measured Current0.0A0.0-8.0A0.0-12.0A
Measured Power-280.0W-
Temperature Measurement Range (°C)0.0-99.0
Power-Off Memory Count1-1
Supported PD Protocol Versions2.03.03.1 AVS EPR
PPS Supported Range3.3V-36.0V
Number of PDOs Captured0-7
Supported QC Protocol Versions2.03.04.0+
Sampling Frequency2MHz-5Mhz
Ripple Measurement Range0mV-1.0V
Screen Dimming Frequency-10KHz-
Screen Dimming Range-50%100%
Current Direction Threshold--0.02A
Voltage Threshold--0.02V
CC and IO Power Measurement Range0.0V0.4-1.2V5.0V
DN and DP Power Measurement Range0.0V-3.3V
Auto-Rotate ScreenSupport--
Offline SaveSupport--
Emarker SimulationSupport--
PDO Message ParsingSupport--
Language SwitchingChinese (English)--
PDO Mode DeceptionSupport--
QC Mode DeceptionSupport--
Statistical InformationSupport--
Capacity MeasurementSupport--
Data IO Voltage DisplaySupport--
Ripple MeasurementSupport--
Curve PlottingSupport--
Ripple Sampling, Mode SwitchingSupport--
Pause Display DataSupport--
Protocol Combination TestSupport--
Pass-Through ModeSupport--
Current Direction IndicationSupport--
Real-Time Range DisplaySupport--
Auto Screen SaverSupport--
Screen Brightness AdjustmentSupport--
Body Temperature ReadingSupport--

7. Maintenance

  • Keep the device clean and free from dust.
  • Avoid exposing the device to extreme temperatures or humidity.
  • Do not attempt to disassemble or repair the device yourself, as this will void the warranty.
  • Store in a dry place when not in use.

8. Troubleshooting

If you encounter any issues with your KWS-X1 Type C Tester, please consider the following:

  • No Display/Power: Ensure the tester is correctly connected between a powered source and a device.
  • Inaccurate Readings: Verify that the cables used are in good condition. Compare readings with other reliable meters if available.
  • Ripple Measurement Issues: If ripple measurement takes a few seconds to stabilize or shows unusually high initial values (e.g., 1000), this might be a software behavior. Allow it to settle for accurate readings.
  • Protocol Detection Failure: Ensure the connected devices support the fast charging protocols you are trying to test.

For persistent issues, refer to the official support channels or contact the seller.

9. User Tips

  • Users have found this device to be accurate, especially when compared to cheaper models like KWS-2301C, 2302C, and 2303C.
  • The PD triggering function works reliably.
  • The device is generally well-regarded for its performance.

10. Warranty and Support

For warranty information and technical support, please refer to the documentation provided by your retailer or contact the manufacturer directly. Keep your proof of purchase for any warranty claims.

A user manual in PDF format is available for download: View User Manual (PDF)