Wallpad Wallpad Wall Box

Contents

Wallpad 86 Type Dry Lining Box Instruction Manual

1. Product Overview

The Wallpad 86 Type Dry Lining Box is designed for installing electrical switches and sockets in gypsum board, drywall, and plasterboard walls. Its robust PVC construction ensures durability and fire resistance, making it suitable for modern interior electrical installations.

Assortment of Wallpad 50mm Depth Dry Boxes

Figure 1: Wallpad 50mm Depth Dry Boxes

2. Safety Information

WARNING: Always cut off the power supply before installation and use an electric tester to confirm no electricity. Do not drill or chisel without checking the position of hidden wires, water pipes, or gas pipes to avoid leakage or short circuit. Use tools correctly to prevent injury. The installation height must comply with home electrical safety requirements. Do not modify the box structure or use non-compatible electrical components. If you are not familiar with electrical operations, please hire a professional electrician.

  • Not suitable for industrial high-load electrical equipment.
  • Do not install in damp areas (e.g., bathroom without waterproof treatment) or outdoor environments.
  • Maximum load capacity: 2kg (total weight of installed electrical components).

3. Setup and Installation

3.1 Tools and Materials Needed

Tools: Electric drill, screwdriver, level, tape measure, pencil.

Materials: Wallpad 86-type wall mount box, expansion screws/plastic expansion tubes, self-tapping screws, decorative cover.

3.2 Installation Procedure

The Wallpad Dry Lining Box features adjustable clips/clamps suitable for plasterboard thicknesses between 5.3mm and 32mm.

Installation diagram showing adjustable clip mechanism

Figure 2: Adjustable Clip/Clamp for Plasterboard Installation

  1. Adjustable Clip/Clamp plasterboard with the edge of the bottom box.
  2. Cross Section of Drywall/Plasterboard (suitable thickness: 5.3-32mm).
  3. The Body of Box.
  4. The exposed edge of Box.

3.2.1 Concealed Installation (New Decoration)

  1. Mark the installation position with a pencil (socket: 30cm above ground; switch: 120-130cm above ground).
  2. Chisel a groove slightly larger than the box (86x86x40/50mm) on the wall.
  3. Place the box into the groove, adjust it to be level using a level tool, and fix it with cement mortar.
  4. Wait 24 hours for the mortar to cure. Then, install the switches/sockets and cover with the decorative cover.

3.2.2 Surface-mounted Installation (Renovation)

  1. Mark screw hole positions on the wall according to the box's hole spacing (60mm).
  2. Drill holes and insert expansion screws/plastic expansion tubes.
  3. Align the box with the drilled holes and fix it firmly with self-tapping screws (check for levelness).
  4. Install the electrical components and decorative cover.

4. Operating and Usage

The Wallpad Dry Lining Boxes are designed to accommodate various standard switch and socket plates.

4.1 Compatible Switch and Socket Types

Box TypeCompatible Switch & Socket SizeDescription
86 Type Box (1 Gang)86x86mmFor single switch or socket plates.
Double 86 Socket (2 Gang)172x86mm or 2pcs (86x86mm)For double switch/socket plates or two single plates side-by-side.
Triple Dry Box (3 Gang)258x86mm or 3pcs (86x86mm)For triple switch/socket plates or three single plates side-by-side.
118 Type Box118x75mmFor specific 118-type electrical components.
146 Type Box146x86mmFor specific 146-type electrical components.
EU BoxEU StandardFor EU standard switches and sockets.
1 Gang Dry Box with dimensions2 Gang Dry Box with dimensions3 Gang Dry Box with dimensions

Figure 3: Dimensions for 1, 2, and 3 Gang Dry Boxes

5. Maintenance

The Wallpad Dry Lining Box requires minimal maintenance. To clean, simply wipe the exposed surfaces with a dry or slightly damp cloth. Avoid using abrasive cleaners or solvents that could damage the PVC material.

6. Troubleshooting

As a passive electrical component, troubleshooting for the dry lining box is limited. Most issues relate to installation.

  • Box not fitting flush: Ensure the wall opening is correctly sized and free of debris. For concealed installation, ensure mortar is applied evenly. For surface-mounted, check screw alignment.
  • Switch/socket plate not attaching securely: Verify that the mounting screws (M3.5) are correctly aligned with the box's internal threads and are tightened appropriately. Ensure the box itself is firmly secured to the wall.
  • Box appears unstable: Recheck all mounting points. For concealed installation, ensure the mortar has fully cured and provides solid support. For surface-mounted, ensure expansion plugs are properly seated and screws are tight.

7. Specifications

FeatureSpecification
Brand NameWallpad
Model NumberWallpad Wall Box
MaterialPlastic (PVC)
Depth50mm
OriginMainland China
CertificationCE
EU LVD VoltageLow voltage: Below 50Vac or 75Vdc
Screws Included3.5mm Screws
Plasterboard ThicknessAdjustable for 5.3mm - 32mm
Load CapacityMax. 2kg
Fire ResistanceFireproof PVC Material
High-concerned chemicalNone
Product details showing fire retardant, rust prevention, sturdy, wiring hole

Figure 4: Key Features and Construction Details

8. Warranty and Support

8.1 Warranty Information

This Wallpad product comes with a 12-year warranty. We guarantee to replace any product found to have manufacturing defects within this period (excluding man-made damage).

8.2 Manufacturer Information

Manufacturer Full Name: WenZhou Wallpad Electric Co.,LTD
Manufacturer Country: China
Manufacturer City: Wenzhou Zhejiang Province
Manufacturer Detailed Address: No.86 Jin Feng Xi Lu, Tian He Street, Long Wan Qu, Wen Zhou City, China
Postal Code: 325000
Phone Number: 86-15167890330
Email Address: 278907249@qq.com

8.3 Compliance Information

Compliance Mark: CE Mark
Applicable Directives & Standards:

  • EU Directive: 2014/35/EU (Low Voltage Directive)
  • Harmonized Standards: EN 60670-1:2018, IEC 60670-1:2018
  • National Standard (China): GB/T 17466-2022

8.4 Responsible Person for Compliance (EU Region)

Name: Humiss International B.V.
Country: Netherlands
Address: Joop Geesinkweg 701, Amsterdam-Duivendrecht, the Netherlands
Phone Number: +31 (0)20 369 8116
Email Address: business@humiss.com

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.