1. Product Overview
The Wallpad 86 Type Dry Lining Box is designed for installing electrical switches and sockets in gypsum board, drywall, and plasterboard walls. Its robust PVC construction ensures durability and fire resistance, making it suitable for modern interior electrical installations.

Figure 1: Wallpad 50mm Depth Dry Boxes
2. Safety Information
WARNING: Always cut off the power supply before installation and use an electric tester to confirm no electricity. Do not drill or chisel without checking the position of hidden wires, water pipes, or gas pipes to avoid leakage or short circuit. Use tools correctly to prevent injury. The installation height must comply with home electrical safety requirements. Do not modify the box structure or use non-compatible electrical components. If you are not familiar with electrical operations, please hire a professional electrician.
- Not suitable for industrial high-load electrical equipment.
- Do not install in damp areas (e.g., bathroom without waterproof treatment) or outdoor environments.
- Maximum load capacity: 2kg (total weight of installed electrical components).
3. Setup and Installation
3.1 Tools and Materials Needed
Tools: Electric drill, screwdriver, level, tape measure, pencil.
Materials: Wallpad 86-type wall mount box, expansion screws/plastic expansion tubes, self-tapping screws, decorative cover.
3.2 Installation Procedure
The Wallpad Dry Lining Box features adjustable clips/clamps suitable for plasterboard thicknesses between 5.3mm and 32mm.

Figure 2: Adjustable Clip/Clamp for Plasterboard Installation
- Adjustable Clip/Clamp plasterboard with the edge of the bottom box.
- Cross Section of Drywall/Plasterboard (suitable thickness: 5.3-32mm).
- The Body of Box.
- The exposed edge of Box.
3.2.1 Concealed Installation (New Decoration)
- Mark the installation position with a pencil (socket: 30cm above ground; switch: 120-130cm above ground).
- Chisel a groove slightly larger than the box (86x86x40/50mm) on the wall.
- Place the box into the groove, adjust it to be level using a level tool, and fix it with cement mortar.
- Wait 24 hours for the mortar to cure. Then, install the switches/sockets and cover with the decorative cover.
3.2.2 Surface-mounted Installation (Renovation)
- Mark screw hole positions on the wall according to the box's hole spacing (60mm).
- Drill holes and insert expansion screws/plastic expansion tubes.
- Align the box with the drilled holes and fix it firmly with self-tapping screws (check for levelness).
- Install the electrical components and decorative cover.
4. Operating and Usage
The Wallpad Dry Lining Boxes are designed to accommodate various standard switch and socket plates.
4.1 Compatible Switch and Socket Types
| Box Type | Compatible Switch & Socket Size | Description |
|---|---|---|
| 86 Type Box (1 Gang) | 86x86mm | For single switch or socket plates. |
| Double 86 Socket (2 Gang) | 172x86mm or 2pcs (86x86mm) | For double switch/socket plates or two single plates side-by-side. |
| Triple Dry Box (3 Gang) | 258x86mm or 3pcs (86x86mm) | For triple switch/socket plates or three single plates side-by-side. |
| 118 Type Box | 118x75mm | For specific 118-type electrical components. |
| 146 Type Box | 146x86mm | For specific 146-type electrical components. |
| EU Box | EU Standard | For EU standard switches and sockets. |



Figure 3: Dimensions for 1, 2, and 3 Gang Dry Boxes
5. Maintenance
The Wallpad Dry Lining Box requires minimal maintenance. To clean, simply wipe the exposed surfaces with a dry or slightly damp cloth. Avoid using abrasive cleaners or solvents that could damage the PVC material.
6. Troubleshooting
As a passive electrical component, troubleshooting for the dry lining box is limited. Most issues relate to installation.
- Box not fitting flush: Ensure the wall opening is correctly sized and free of debris. For concealed installation, ensure mortar is applied evenly. For surface-mounted, check screw alignment.
- Switch/socket plate not attaching securely: Verify that the mounting screws (M3.5) are correctly aligned with the box's internal threads and are tightened appropriately. Ensure the box itself is firmly secured to the wall.
- Box appears unstable: Recheck all mounting points. For concealed installation, ensure the mortar has fully cured and provides solid support. For surface-mounted, ensure expansion plugs are properly seated and screws are tight.
7. Specifications
| Feature | Specification |
|---|---|
| Brand Name | Wallpad |
| Model Number | Wallpad Wall Box |
| Material | Plastic (PVC) |
| Depth | 50mm |
| Origin | Mainland China |
| Certification | CE |
| EU LVD Voltage | Low voltage: Below 50Vac or 75Vdc |
| Screws Included | 3.5mm Screws |
| Plasterboard Thickness | Adjustable for 5.3mm - 32mm |
| Load Capacity | Max. 2kg |
| Fire Resistance | Fireproof PVC Material |
| High-concerned chemical | None |

Figure 4: Key Features and Construction Details
8. Warranty and Support
8.1 Warranty Information
This Wallpad product comes with a 12-year warranty. We guarantee to replace any product found to have manufacturing defects within this period (excluding man-made damage).
8.2 Manufacturer Information
Manufacturer Full Name: WenZhou Wallpad Electric Co.,LTD
Manufacturer Country: China
Manufacturer City: Wenzhou Zhejiang Province
Manufacturer Detailed Address: No.86 Jin Feng Xi Lu, Tian He Street, Long Wan Qu, Wen Zhou City, China
Postal Code: 325000
Phone Number: 86-15167890330
Email Address: 278907249@qq.com
8.3 Compliance Information
Compliance Mark: CE Mark
Applicable Directives & Standards:
- EU Directive: 2014/35/EU (Low Voltage Directive)
- Harmonized Standards: EN 60670-1:2018, IEC 60670-1:2018
- National Standard (China): GB/T 17466-2022
8.4 Responsible Person for Compliance (EU Region)
Name: Humiss International B.V.
Country: Netherlands
Address: Joop Geesinkweg 701, Amsterdam-Duivendrecht, the Netherlands
Phone Number: +31 (0)20 369 8116
Email Address: business@humiss.com