1. Introduction
Thank you for purchasing the Myoslim Neo Portable EMS Electromagnetic Muscle Stimulate Fat Burn Body Slimming Shaping Muscle Build Beauty Machine. This manual provides essential information regarding the instrument's working principle, precautions, operation, and maintenance. Please read it carefully before use to ensure proper operation and to prevent damage to the instrument or potential harm.
This instrument is designed for general human body shaping, utilizing innovative compression and vibration to improve lymphatic drainage, enhance blood circulation, reduce cellulite, relieve skin relaxation and aging, and contribute to the conditioning and detoxification of facial and body muscles.
The manufacturer is responsible for the safety and reliability of the instrument under the following conditions:
- Installation, reorganization, modification, and maintenance are carried out by professionals designated or authorized by the company.
- Electrical equipment connected meets the technical parameters specified in this manual.
- Operation is performed according to this user manual.
Improper use, or use for functions other than those specified, may lead to malfunction, endanger health, or damage the instrument. All consequences arising from such use will be borne by the user.
2. Product Overview and Features
The Myoslim Neo machine employs advanced EMS (Electromagnetic Muscle Stimulation) technology combined with RF (Radio Frequency) for comprehensive body sculpting. It features a continuous brand new air-cooled system for stable performance.
2.1 Instrument Principle
The inner ball roller handle rotates 360° to create compression micro-vibration. As the ball rotates and applies pressure, it generates a "pulsation compression" effect, facilitating continuous push-pull motions. This action stretches cells, stimulates cell activity, improves blood flow and oxygenation, and helps loosen fat deposits for decomposition, reducing cellulite and smoothing skin.
2.2 Key Benefits (Five Improvements)
- Reshaping Action: Reshapes body contour and smooths wrinkles.
- Sedation: Improves oxygen and eliminates pain.
- Drain Action: Eliminates toxins and helps lymphatic drainage.
- Vascular Effect: Improves blood circulation and nourishes tissues.
- Muscle Action: Tones muscles and tightens tissues.
Diagram illustrating the five key improvements of the Myoslim Neo treatment.
2.3 Functions and Operating Range
The Myoslim Neo is designed to address various body concerns:
| Function Category | Specific Functions |
|---|---|
| When applied to the body |
|
| When applied to the face |
|
2.4 Characteristics of Inner Ball Roller Handle
- Unique 360° intelligent rotating drum handle, offering continuous long-term operation, safety, and stability.
- An LED display on the handle shows the current speed.
- The roller handle includes a key for controlling start or pause.
- The steel ball is flexible and smooth, ensuring a gentle and non-stinging rolling process for optimal massage and lifting results.
- No need for the user to apply excessive pressure; operation is simple and safe.
2.5 EMS Technology Overview
The Myoslim Neo utilizes EMS technology to stimulate nerves, causing muscles to continuously expand and contract. This extreme training deepens muscle remodeling, leading to myofibril growth (muscle enlargement) and the production of new collagen chains and muscle fibers (muscle hyperplasia), ultimately increasing muscle density and volume.
The 100% limit muscle contraction triggered by this technology facilitates significant fat decomposition. Fatty acids are broken down from triglycerides and accumulate in fat cells. High concentrations of fatty acids induce apoptosis in fat cells, which are then excreted from the body through normal metabolism within a few weeks. This process allows the EMS treatment to strengthen and increase muscles while simultaneously reducing fat.
The HI-EMT technology induces approximately 20,000 forced muscle contractions per session, which are supramaximal contractions not achievable through voluntary muscle action. The continuous freezing technology ensures the treatment head does not generate high temperatures, maintaining a stable magnetic wave output. The Myoslim Neo machine delivers a magnetic wave intensity of 14 Tesla, offering unparalleled results.
3. Setup Instructions
Before operating the Myoslim Neo machine, ensure all components are correctly connected and secured.
3.1 Unpacking and Component Identification
Refer to the "Packing List" section for a complete list of components. Ensure all items are present and undamaged.
Front view of the Myoslim Neo machine.
Side view of the Myoslim Neo machine.
Rear view of the Myoslim Neo machine, highlighting connection ports.
3.2 Connecting the Handles
The machine comes with various handles for different applications. Connect the desired handles to the corresponding ports on the machine. Ensure a secure connection.
Close-up of the handles and their connection to the main unit.
3.3 Power Connection
Connect the power cord to the machine's power input and then to a suitable power outlet (AC 110V-220V, 50/60Hz). Ensure the power switch on the back of the machine is in the OFF position before connecting.
Video demonstrating the power connection and initial setup of the Myoslim Neo machine.
As shown in the video:
- Connect the power cord of the machine.
- Turn on the switch button on the back of the machine.
4. Operating Instructions
The Myoslim Neo features a diversified touch screen interface for easy operation. All handles can only be operated by professional operators.
4.1 Powering On and Interface Navigation
After connecting the power, press the power button on the front of the machine. The screen will display the Myoslim logo and then transition to the main interface.
Diversified touch screen interface for easy navigation.
From the main interface, you can select "LIST", "PATTERN", or "RECORDS".
4.2 Selecting Treatment Mode (Pattern)
The machine offers different patterns (modes) for treatment. You can choose between Pattern 1 and Pattern 2.
Pattern selection screen.
As shown in the video:
- Mode 1 (Pattern 1): Allows adjustment of machine details, gender, age, and usage according to customer needs. This mode is suitable for new practitioners or new treatments.
- Mode 2 (Pattern 2): Provides more detailed energy adjustment and allows adjusting the size of the machine according to the customer's own needs.
4.3 Applying the Handles
Once the mode is selected and parameters are set, apply the handles to the target area.
Application positions for the inner ball roller handle.
As shown in the video:
- Place the large handle on your abdomen or hips.
- Tie the small handle to the handle or leg using the provided straps.
- Tie the bandage, adjust the energy of the machine, click the start button, and the machine will achieve the effect of weight loss through electromagnetic and high-frequency vibration.
Note: Before starting the operation, touch the EMS handle vertically to the use part, and then turn on the main switch to adjust the intensity of the operation mode. Always start with the lowest intensity level and gradually increase it based on user comfort and skin tolerance.
4.4 Interface Parameters for Big Wheel (Example)
| Instruction | Description |
|---|---|
| Energy adjustment key | RF, 0~50 |
| Time adjustment key | 1~60 min |
| Rotating speed adjustment key | 0~10 |
| Rotation direction adjustment key | FWD: clockwise, / REV: counterclockwise. |
| Stop therapy | Shut down the handle |
| Start/pause therapy | Handle start/pause operation |
| Return | Return to the "Function Selection" |
The parameters for the small wheel are similar, allowing for precise control over the treatment.
5. Maintenance
5.1 Daily Inspection
- Check instruments and components regularly.
- Regularly check whether the connection between the power socket and the grounding wire is reliable.
- Regularly check whether the connection between the power socket and the grounding wire is reliable.
5.2 Cleaning
- Clean the instrument regularly to ensure sanitary conditions and normal operation.
- Do not clean internal circuits with liquids.
- Before cleaning, turn off the power and unplug the instrument. Wipe the equipment shell with a wet cloth, soapy water, or neutral detergent.
5.3 Replacing the Fuse
- When replacing the fuse, always turn off the power supply and unplug the machine to prevent electric shock.
6. Troubleshooting
This section outlines common issues and their solutions.
| Fault Phenomenon | Causes | Exclusions and Workarounds |
|---|---|---|
| Device not working |
|
|
| Handle not working | Check the handle for looseness. | Reposition the handle. |
7. Specifications
Detailed technical specifications for the Myoslim Neo machine:
| Attribute | Value |
|---|---|
| Brand Name | MYOSLIM |
| Item Type | Massage & Relaxation |
| Application | BODY (Abdomen, Buttocks, Thighs, Arms, Calves) |
| Material | ABS |
| Origin | Mainland China |
| Certification | CE, RoHS |
| Power Supply | AC 110V-220V, 50/60Hz |
| Maximum Output Power | 6500W |
| Max Output Working Frequency | 200Hz+ |
| Magnetic Wave Intensity | 14 Tesla |
| Screen Size | 15 inches |
| Screen Type | Resistance screen |
| Screen Resolution | 1024*768 |
| Equipment Size | 52x32x43cm |
| Net Weight of Equipment | 16.6kg |
| Packing Size | 55x55x64cm (from PRODUCT_PACKAGE) |
| Packing Weight | 44.4kg (from PRODUCT_PACKAGE) |
| Frequency | 448KHz |
| Small Handle Speed | 400rpm |
| Large Handle Speed | 400rpm |
| Fuse | 500V 3A Φ6×30 |
| Color | White |
| Handle Quantity Options | 2/4/5 pcs |
| Accessories | Belts (3 sizes), Power Cable, User Manual |
| Function | Muscle Building, Fat Burning, Body Sculpting, Skin Tightening |
| Technology | EMS Hiemt+ (R/F), EMS/HIEMT+RF 2 in 1 Slimming, High Intensity Pulsed Electromagnetic Body Sculpting |
| Technology Advantage | No-invasive non-exercise healthy slimming |
| Advantage | Non Exercise Body Sculpt Machine |
8. Packing List
The following items are included in the product package:
| Serial | Name | Quantity | Picture |
|---|---|---|---|
| 1 | Host | 1 set | ![]() |
| 2 | Roller handle | Big*1 Small*1 | ![]() |
| 3 | Abdominal Muscle Piece and Connecting Line | 1 | ![]() |
| 4 | Power cable | 1 | ![]() |
| 5 | Electronic manual | 1 copy | ![]() |
9. User Tips
- The machine is noted for its simple operation and beautiful design.
- Users appreciate the painless treatment and lack of recovery period, making it convenient for home use while engaging in other activities like watching TV.
- It's a good investment for those who want to receive treatments at home without frequent visits to beauty salons.
10. Warranty and Support
The Myoslim Neo machine comes with a comprehensive warranty and support:
- Machine Replacement: A new machine can be replaced within 7 days from the date of purchase (with receipt).
- Mainframe Warranty: The mainframe is guaranteed for one year from the date of receipt, excluding fragile parts and other non-warranty parts or expired warranty periods.
- Maintenance & Updates: Maintenance and updates are available, with fees charged appropriately.
- Freight for Repairs: If the instrument is damaged and needs repair, the company covers all freight within six months of receipt. For repairs between six months and one year, freight costs are split. After one year, the buyer bears all freight costs.
- Accessories Warranty: The warranty period for accessories is 3 months (note: non-human damage).
- After-Sale Service: Online service and technical support are provided. Free shipping of accessories is available if necessary.
10.1 Exclusions from Free Warranty Service
Free warranty service is not provided for failures caused by personal reasons, including:
- Faults caused by unauthorized disassembly and modification of the product.
- Failure caused by accidental fall.
- Failure caused by lack of reasonable maintenance.
- Failing to follow the correct instructions in the manual.
For any questions, service needs, or information, please contact the manufacturer directly.
11. Storage and Transportation Management
11.1 Storage
The instrument should be stored in its original packing box, in a well-ventilated room, with an ambient temperature of -10°C to 40°C and relative humidity not exceeding 93%. It must not be placed near harmful, flammable, explosive, or corrosive gases.
11.2 Transportation
The packaged instrument is suitable for road, railway, air, and water transportation. During loading, unloading, and transit, prevent severe vibration, moisture, and mixing with flammable or corrosive substances. Specific requirements are detailed in the order contract.
12. Safety Precautions and Contraindications
12.1 General Precautions
- Do not use the instrument immediately after a full meal; wait at least one hour.
- Remove any metal jewelry before using the instrument.
- After use, replenish water in time.
- Avoid overeating; maintain a balanced diet and sufficient sleep.
- Strengthen moisturizing and sun protection after use.
- Avoid spicy food.
- Avoid soaking in hot springs and saunas for three days after use.
12.2 Contraindications
The Myoslim Neo machine should NOT be used by individuals with the following conditions:
- People with large wounds or ulcers on their skin.
- Patients with heart disease (e.g., arrhythmia), especially those with pacemakers.
- Cancer patients.
- Patients with infectious diseases.
- Pregnant women, lactating women, and menstruating women.
- Major surgical patients and diabetic patients.
- People with any metal implants in their bodies.
- People with cerebrovascular disease (stroke patients).
WARNING: DO NOT USE OVER HEART AREA HEAD AREA OR ON PATIENTS WITH IMPLANTS.