1. Introduction
This DALY Smart Inverter BMS (Battery Management System) is specifically designed for energy storage battery systems, integrating collection, management, and communication functions. With the increasing application of lithium iron batteries, there is a growing demand for high-performance, reliable, and cost-effective battery management solutions. This 4th generation BMS is suitable for both indoor and outdoor energy storage applications, including home energy storage, photovoltaic energy storage, and communication energy storage.
The integrated design of the BMS enhances assembly and test efficiency for battery pack manufacturers, reducing production costs and improving overall installation quality.
2. Product Features
- 4th Generation Home Energy Storage BMS: Designed for modern energy storage needs.
- Optional 2A Active Balancing: Features peak 1A or 2A active balancing current (depending on model) to quickly balance battery voltage differences, reduce energy loss, and extend battery life.
- APP/IoT Management: Connects via Bluetooth (BT) or WiFi for remote monitoring and management through a self-developed mobile application and the DALY Cloud platform.
- 10A Parallel Expansion: Supports peak current limit of 10A for parallel expansion, allowing up to 16 battery packs to be connected in parallel, preventing high current shock.
- Intelligent Interaction with 3.5-inch HD Screen: Provides a better interactive experience with single pack data, parallel summary data, information alarms, customizable UI, and display for up to 16 parallel packs.
- Modular Design: Improves assembly efficiency and features bottom-side cooling with an aluminum heatsink and wavy heatsink for enhanced heat dissipation and longer life.
- Automatic Inverter Protocol Identification: Automatically identifies mainstream inverter protocols, with manual setup available via APP or PC master for non-auto-recognized protocols.
- Automatic BMS Address Identification: Saves time in debugging DIP switches and avoids communication conflicts.
- Multi-interface Expandability: Dual UART, CAN, RS485, and other communication interfaces allow for expansion with smart accessories like GPS modules, heating modules, and various display screens.
- Multiple Security Protections: Includes overcharge, over-discharge, overcurrent, short circuit, temperature, and static electricity protection.








3. Packing List
The following components are typically included with your DALY Smart Inverter BMS. Please note that the list may vary based on the specific model (e.g., WiFi model includes a WiFi module, non-display model does not include a display).

- BMS (Main Board)
- Interface Board
- 3.5-inch Display (Optional, for models with display)
- RJ45-RS485 Line (Gift)
- Bluetooth Module (Gift, for BT models)
- Key Switch (Gift)
- Display Line
- NTC (Temperature Sensor) x2 (4-way)
- Packing Box
- Interface Board Cable 1 & 2
- Sampling Cable
- Manual (PDF version available online)
- Screws x2
4. Specifications
4.1 General Specifications
| Attribute | Value |
|---|---|
| Brand Name | DALY |
| Type | LiFePO4 Battery BMS |
| Handware or Smart | SMART BMS |
| Usage Scenario | Energy Storage BMS |
| Certification | CE, FCC, RoHS |
| Function | Overcharge Protection, Over Discharge Protection, Overcurrent Protection, Short Circuit Protection |
| Communication Method | UART/RS485/CAN |
| Inverter BMS Type | Split Type |
| Origin | Mainland China |
4.2 Model-Specific Specifications (8/16S | LiFePO4 | 100-200A)

| Product Model | 4th Gen-LK BMS | 4th Gen-LM BMS |
|---|---|---|
| Continuous Charge/Discharge Current | 100A | 150A/200A |
| Applicable Battery Type | LiFePO4 | LiFePO4 |
| Series Range | 8S/16S | 8S/16S |
| Active Balancing Current (Optional) | Peak 1A | Peak 2A |
| Passive Balancing Current | 150mA | 150mA |
| Parallel Current Limiting | Peak 10A (Continuous 3A) | Peak 10A (Continuous 3A) |
| UART | ✓ | ✓ |
| RS485 | Optional | Optional |
| CAN | Optional | Optional |
| Key Switch | ✓ | ✓ |
| Dry Contact | Optional | Optional |
| Integrated Type Passive Balancing BMS Dimension | 230*110*24.5mm | 320*110*27.7mm |
| Integrated Type Active Balancing BMS Dimension | 230*110*35mm | 320*110*35.2mm |
| Split Type Passive Balancing BMS Dimension | Mainboard: 230*110*25mm Interface board: 155*30*25mm | Mainboard: 320*110*24.5mm Interface board: 155*30*25mm |
| Split Type Active Balancing BMS Dimension | Mainboard: 230*110*32mm Interface board: 155*30*25mm | Mainboard: 320*110*32mm Interface board: 155*30*25mm |
| Sampling Cable | 24AWG L=600mm (8S) / 800mm (16S) | 24AWG L=650mm |
| NTC | 24AWG L=650mm | 24AWG L=650mm |
| Optional Accessories | 3.2-inch display screen, 3.5-inch TFT color high-definition screen, 4.3-inch IPS high-definition capacitive touchscreen, Bluetooth module, WiFi module, 4G positioning module, Heating module | 3.2-inch display screen, 3.5-inch TFT color high-definition screen, 4.3-inch IPS high-definition capacitive touchscreen, Bluetooth module, WiFi module, 4G positioning module, Heating module |
Note: Product dimensions are given as length * width * thickness, with a dimensional tolerance range of ±0.5 mm.
4.3 Electrical Parameters (Charge/Discharge & Equalization)
| Test Content | Default Parameters (Li-ion) | Default Parameters (LiFePO4) | Unit |
|---|---|---|---|
| Rated Discharge Current | 150/200 | A | |
| Charge Voltage | =4.2*n | =3.65*n | V |
| Rated Charging Current | 150/200 | A | |
| Balance Turn-on Voltage | 4.0 | 3.4 | V |
| Balance Off Voltage | 4.2 | 3.6 | V |
| Equalize Opening Voltage Difference | 20 | mV | |
| Balance Current | Max 2000 | mA | |
4.4 Protection Parameters
| Protection Type | Test Content | Default Parameters | Unit |
|---|---|---|---|
| Single Cell Overcharge Level 1 | Over-charge alarm voltage | 4.2±0.05 (Li-ion), 3.6±0.05 (LiFePO4) | V |
| Over-charge alarm delay | 1±0.8 | S | |
| Over-charge release voltage | 4.1±0.05 (Li-ion), 3.5±0.05 (LiFePO4) | V | |
| Single Cell Over-discharge Level 1 | Discharge alarm voltage | 2.8±0.05 | V |
| Discharge alarm delay | 1±0.8 | S | |
| Discharge alarm release voltage | 2.9±0.05 | V | |
| Short-circuit Protection | Short-circuit protection current | 1500/2000 | A |
| Short-circuit protection delay | 300±200 | uS | |
| Charging High Temperature Level 1 | High temperature level 1 alarm | 55±2 | °C |
| High temperature level 1 alarm delay | 1±0.8 | S | |
| High temperature level 1 alarm release | 50±2 | °C | |
| Discharging High Temperature Level 1 | High temperature level 1 alarm | 60±2 | °C |
| High temperature level 1 alarm delay | 1±0.8 | S | |
| High temperature level 1 alarm release | 55±2 | °C | |
| Charging Low Temperature Level 1 | Low temperature level 1 alarm | 5±2 | °C |
| Low temperature level 1 alarm delay | 1±0.8 | S | |
| Low temperature level 1 alarm release | 10±2 | °C | |
| Discharging Low Temperature Level 1 | Low temperature level 1 alarm | -15±2 | °C |
| Low temperature level 1 alarm delay | 1±0.8 | S | |
| Low temperature level 1 alarm release | -10±2 | °C |
4.5 BMS Dimensions
| Component | Dimensions (L*W*H) |
|---|---|
| BMS Main Board | 320*110*33 mm |
Note: This dimension does not include cables/accessories. Refer to 2D/3D models for detailed installation space.
4.6 Inverter Communication Protocols
| Protocol Type | Protocol Abbreviation | Protocol Name | Remark |
|---|---|---|---|
| RS485 Protocol | SUNSYNK | 阳光 | |
| RS485 Protocol | DEYE | 德业 | Support inverter self-identification |
| RS485 Protocol | PYLON | 派能 | Support inverter self-identification |
| RS485 Protocol | SOROTEC | 索瑞德 | |
| RS485 Protocol | SACOLAR | 尚科 | Support inverter self-identification |
| RS485 Protocol | GROWAT | 古瑞瓦特 | Support inverter self-identification |
| RS485 Protocol | SOFAR | 首航 | Support inverter self-identification |
| RS485 Protocol | SRNE | 硕日 | Support inverter self-identification |
| RS485 Protocol | VOLTRONICPOWER | 日月元 | Support inverter self-identification |
| RS485 Protocol | STUDER | 特能 | |
| CAN Protocol | SUNSYNK | 阳光 | |
| CAN Protocol | GOODWE | 固德威 | |
| CAN Protocol | DEYE | 德业 | |
| CAN Protocol | XMT | ||
| CAN Protocol | SOLARK | ||
| CAN Protocol | PYLON | 派能 | |
| CAN Protocol | MEGAREVO | 迈格瑞能 | |
| CAN Protocol | SOROTEC | 索瑞德 | |
| CAN Protocol | SRNE | 硕日 | |
| CAN Protocol | SOLIS | 锦浪 | |
| CAN Protocol | LUXPOWERTEK | 鹏程 | |
| CAN Protocol | SACOLAR | 尚科 | |
| CAN Protocol | GROWAT | 古瑞瓦特 | |
| CAN Protocol | SOFAR | 首航 | |
| CAN Protocol | MUST | 美克 | |
| CAN Protocol | VICTRONENERGY | ||
| CAN Protocol | SMA | ||
| CAN Protocol | AISWEI | 爱士惟 | |
| CAN Protocol | STUDER | 特能 |
5. Setup Instructions
5.1 Wiring Diagram (Split Type - 100A Active Balancing Example)

5.2 BMS Connection Steps
- Weld the cable: The first cable (black cable) is connected to the negative terminal of the battery. The second cable (red cable) is connected to the positive terminal of the first string of batteries, and the third cable (red cable) is connected to the positive terminal of the second string of batteries. Continue this pattern until all cables are connected.
- Check the cables: After connecting the cables, measure the voltage between two adjacent cables to confirm there are no wrong or missing connections in the cable welding sequence.
- Fix the BMS: Secure the BMS, then measure and confirm that the voltage between B- and P- of the BMS is correct. Insert the cable into the BMS.
- Plug in the NTC cable: Use the B+ line to connect the positive terminal of the battery pack.
- Awaken the BMS: After completing the above steps, the BMS should awaken and work normally. If not, please review and repeat the steps.
5.3 Parallel Communication Wiring Diagram

5.4 Interface Definitions
The BMS features various interfaces for communication and control. Refer to the diagrams below for detailed pinouts and connections.

B-/P-/B+ Interface
- B- Interface: Battery negative terminal. Connects to the battery negative.
- P- Interface: Protection board charge/discharge negative terminal. Connects to the charging and discharging negative terminal.
- B+ Interface: Cell/PACK positive terminal. Used to supply power to the BMS. The positive power terminal P+ is directly connected to the positive electrode of the cell.
RJ45 Network Port
The RJ45 single network port integrates RS485 and CAN functions. It allows communication with a host computer to monitor battery information (voltage, current, temperature, status, production info). Default baud rate is 9600bps.

Other Interfaces
Includes interfaces for sampling cables, NTC sensors, UART, and optional accessories. Refer to the detailed pinout diagrams in the PDF manual for specific connections.
5.5 Main Cable Description
The main cables included are for B-, C-/P-, B+, NTC, RJ45 (RS485 to USB converter), Key Switch, and Interface Board connection. Ensure to use the correct cables for each connection as specified in the packing list and detailed manual.
5.6 APP Download and Wiring Instructions
For detailed wiring instructions and to download the mobile application, scan the QR code provided in the product packaging or visit the official website: https://www.dalyelec.com/service.html.
6. Operation
6.1 LED Indication
The LED indicators provide visual feedback on the BMS status, including alarm, charging, discharging, and remaining battery power.
| Status | RUN LED | Alarm LED | Battery Indicator LED | Description |
|---|---|---|---|---|
| Power Off/Sleep | Off | Off | All Off | |
| Standby | Flash 1 | Off / Flash 3 | Refer to 6.2 | Standby state; A level one alarm triggered but no protection activated (if Flash 3) |
| Charge | On | Off / Flash 3 | Refer to 6.2 | Normal charge; Overcharge alarm (if Flash 3) |
| Discharge | Flash 3 | Flash 3 | Refer to 6.2 | Normal discharge; Over-discharge alarm |
| Failure State | Off | On | All Off | System in temperature, over-current, short circuit protection, etc. Cannot charge or discharge. |
6.2 SOC Indication
| Battery SOC | Charging | Discharging | Standby | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| L4 | L3 | L2 | L1 | L4 | L3 | L2 | L1 | L4 | L3 | L2 | L1 | |
| 0-25% | Off | Off | Off | Flash 2 | Off | Off | Off | On | Off | Off | Off | On |
| 25-50% | Off | Off | Flash 2 | On | Off | Off | On | On | Off | Off | On | On |
| 50-75% | Off | Flash 2 | On | On | Off | On | On | On | Off | On | On | On |
| 75-100% | Flash 2 | On | On | On | On | On | On | On | On | On | On | On |
6.3 Sleep and Wake Up
The BMS can enter sleep mode under specific conditions (e.g., prolonged over-discharge protection, manual button press, or extended inactivity without communication/protection/balancing/current). To wake up the BMS, connect a charger/load, press the reset button, or activate 485/CAN communication.
6.4 Reset Button Functionality
- From Sleep State: Press and release the button to activate the protection board. The LED indicator will light up sequentially for 0.5 seconds from "RUN".
- From Active State (Hibernate): Press and hold the button for 3-6 seconds, then release. The protection board will hibernate, and the LED indicator will light up sequentially for 0.5 seconds from the lowest power indicator.
- From Active State (Reset): Press and hold the button for 6-10 seconds, then release. The protection board will reset, and all LED lights will extinguish.
- From Active State (Auto-coding): Press the button three times within 5 seconds to automatically re-code the BMS.
6.5 Buzzer Logic
- Fault: The buzzer sounds for 0.25 seconds every 1 second.
- Protection: The buzzer sounds for 0.25 seconds every 2 seconds (except for overvoltage protection; for undervoltage, it sounds for 0.25 seconds every 3 seconds).
- Alarm: The buzzer sounds for 0.25 seconds every 3 seconds (except for overvoltage alarm).
7. Maintenance
7.1 Important Precautions
- Voltage Platform Compatibility: Do not mix protection boards from different voltage platforms.
- Wiring Compatibility: Wiring from different manufacturers is not common. Ensure to use the matching wiring provided by DALY.
- Static Electricity Protection: When testing, installing, touching, and using the protection board, take necessary measures to discharge static electricity.
- Heat Dissipation: Do not allow the heat dissipation surface of the protection plate to directly contact the battery. Otherwise, heat will transfer to the battery, affecting its safety.
- Unauthorized Modifications: Do not disassemble or change the components of the protection board.
- Abnormal Operation: If the protection board operates abnormally, stop using it immediately and only resume use after the issue is resolved.
- Correct Polarity: Do not reverse the B- and P- connections, as this may damage the board.
8. Troubleshooting
The DALY Smart Inverter BMS is equipped with various protection mechanisms and indicators to help diagnose issues. Refer to the LED indications and buzzer logic for initial troubleshooting.
8.1 General Fault Conditions
- Failure State (LEDs Off, Alarm LED On): Indicates the system is in temperature, over-current, or short circuit protection. It cannot charge or discharge. Investigate the cause.
- Overcharge Alarm (Charging LED On, Alarm LED Flash 3): Unplug the charger.
- Over-discharge Alarm (Discharge LED Flash 3, Alarm LED Flash 3): Charge the battery.
- Undervoltage Sleep (Discharge LED Off, Alarm LED Off): Charge the battery to exit this state.
8.2 Buzzer Alerts
The buzzer provides audible alerts for faults, protections, and alarms. Understanding these patterns can help identify the type of issue:
- Fault: 0.25s sound every 1s.
- Protection: 0.25s sound every 2s (except overvoltage; undervoltage is 0.25s sound every 3s).
- Alarm: 0.25s sound every 3s (except overvoltage).
For more detailed troubleshooting, refer to the comprehensive PDF manual available online, which includes specific parameter configurations and system diagrams.
9. User Tips
- Regular Monitoring: Utilize the self-developed APP or the 3.5-inch HD display to regularly monitor battery status, voltage, current, and temperature. This proactive approach can help identify potential issues early.
- Proper Ventilation: Ensure the BMS and battery pack are installed in a well-ventilated area to prevent overheating, especially during high charge/discharge cycles.
- Firmware Updates: Check the DALY official website or APP for any available firmware updates to ensure optimal performance and access to new features.
- Cable Management: Keep all wiring neat and secure to prevent accidental disconnections or short circuits. Double-check connections periodically.
10. Warranty & Support
10.1 Warranty Information
From the date of purchase, the product is guaranteed free of charge within one year under normal use. Any round-trip freight costs for warranty service will be borne by the user.
10.2 Additional Resources & Support
For a complete user manual and detailed documentation, please refer to the official PDF:
For technical support or inquiries, you may contact DALY at:
Telephone: 0769-82822953
Address: 21/F, building 7, Tian'an Yungu, No. 14, Gongye South Road, Songshanhu District, Dongguan, China