DALY DL-R16LM-B TJ

Contents

DALY Smart Inverter BMS LiFePo4 User Manual

Model: DL-R16LM-B TJ

Brand: DALY

1. Introduction

This DALY Smart Inverter BMS (Battery Management System) is specifically designed for energy storage battery systems, integrating collection, management, and communication functions. With the increasing application of lithium iron batteries, there is a growing demand for high-performance, reliable, and cost-effective battery management solutions. This 4th generation BMS is suitable for both indoor and outdoor energy storage applications, including home energy storage, photovoltaic energy storage, and communication energy storage.

The integrated design of the BMS enhances assembly and test efficiency for battery pack manufacturers, reducing production costs and improving overall installation quality.

2. Product Features

  • 4th Generation Home Energy Storage BMS: Designed for modern energy storage needs.
  • Optional 2A Active Balancing: Features peak 1A or 2A active balancing current (depending on model) to quickly balance battery voltage differences, reduce energy loss, and extend battery life.
  • APP/IoT Management: Connects via Bluetooth (BT) or WiFi for remote monitoring and management through a self-developed mobile application and the DALY Cloud platform.
  • 10A Parallel Expansion: Supports peak current limit of 10A for parallel expansion, allowing up to 16 battery packs to be connected in parallel, preventing high current shock.
  • Intelligent Interaction with 3.5-inch HD Screen: Provides a better interactive experience with single pack data, parallel summary data, information alarms, customizable UI, and display for up to 16 parallel packs.
  • Modular Design: Improves assembly efficiency and features bottom-side cooling with an aluminum heatsink and wavy heatsink for enhanced heat dissipation and longer life.
  • Automatic Inverter Protocol Identification: Automatically identifies mainstream inverter protocols, with manual setup available via APP or PC master for non-auto-recognized protocols.
  • Automatic BMS Address Identification: Saves time in debugging DIP switches and avoids communication conflicts.
  • Multi-interface Expandability: Dual UART, CAN, RS485, and other communication interfaces allow for expansion with smart accessories like GPS modules, heating modules, and various display screens.
  • Multiple Security Protections: Includes overcharge, over-discharge, overcurrent, short circuit, temperature, and static electricity protection.
DALY 4th Gen Home Energy Storage BMS with 2A balancing and APP/IoT management
Figure 1: DALY 4th Gen Home Energy Storage BMS highlighting key features like 2A balancing, APP/IoT management, and 10A parallel expansion.
Smart technology for new energy storage experience
Figure 2: Overview of the smart technology and new energy storage experience provided by the BMS.
Intelligent Interaction with 3.5-inch HD Screen
Figure 3: Intelligent interaction via the 3.5-inch HD screen, showing data and customizable UI.
Modular Design with Bottom-side Cooling and Wavy Heatsink
Figure 4: Exploded view illustrating the modular design, bottom-side cooling with an aluminum heatsink, and wavy heatsink for improved heat dissipation.
Multi-interface Expand Freely
Figure 5: Diagram showing the multi-interface expandability with dual UART, CAN, RS485, and various smart accessories.
Self-developed APP and DALY Cloud for remote monitoring
Figure 6: Illustration of the self-developed APP and DALY Cloud for remote monitoring and efficient management via BT, WiFi, or GPS modules.
Automatically Identify Mainstream Inverter Protocols and BMS Address
Figure 7: The BMS automatically identifies mainstream inverter protocols and BMS addresses, simplifying setup and preventing communication conflicts.
Multiple Security Protection features
Figure 8: Visual representation of the multiple security protections including overcharge, over-discharge, overcurrent, short circuit, temperature, and static electricity protection.

3. Packing List

The following components are typically included with your DALY Smart Inverter BMS. Please note that the list may vary based on the specific model (e.g., WiFi model includes a WiFi module, non-display model does not include a display).

Packing List for DALY BMS
Figure 9: Visual representation of the components included in the packing list.
  1. BMS (Main Board)
  2. Interface Board
  3. 3.5-inch Display (Optional, for models with display)
  4. RJ45-RS485 Line (Gift)
  5. Bluetooth Module (Gift, for BT models)
  6. Key Switch (Gift)
  7. Display Line
  8. NTC (Temperature Sensor) x2 (4-way)
  9. Packing Box
  10. Interface Board Cable 1 & 2
  11. Sampling Cable
  12. Manual (PDF version available online)
  13. Screws x2

4. Specifications

4.1 General Specifications

AttributeValue
Brand NameDALY
TypeLiFePO4 Battery BMS
Handware or SmartSMART BMS
Usage ScenarioEnergy Storage BMS
CertificationCE, FCC, RoHS
FunctionOvercharge Protection, Over Discharge Protection, Overcurrent Protection, Short Circuit Protection
Communication MethodUART/RS485/CAN
Inverter BMS TypeSplit Type
OriginMainland China

4.2 Model-Specific Specifications (8/16S | LiFePO4 | 100-200A)

DALY BMS 8/16S LiFePO4 100-200A Specifications Table
Figure 10: Detailed specifications for 4th Gen-LK and 4th Gen-LM BMS models.
Product Model4th Gen-LK BMS4th Gen-LM BMS
Continuous Charge/Discharge Current100A150A/200A
Applicable Battery TypeLiFePO4LiFePO4
Series Range8S/16S8S/16S
Active Balancing Current (Optional)Peak 1APeak 2A
Passive Balancing Current150mA150mA
Parallel Current LimitingPeak 10A (Continuous 3A)Peak 10A (Continuous 3A)
UART✓✓
RS485OptionalOptional
CANOptionalOptional
Key Switch✓✓
Dry ContactOptionalOptional
Integrated Type Passive Balancing BMS Dimension230*110*24.5mm320*110*27.7mm
Integrated Type Active Balancing BMS Dimension230*110*35mm320*110*35.2mm
Split Type Passive Balancing BMS DimensionMainboard: 230*110*25mm
Interface board: 155*30*25mm
Mainboard: 320*110*24.5mm
Interface board: 155*30*25mm
Split Type Active Balancing BMS DimensionMainboard: 230*110*32mm
Interface board: 155*30*25mm
Mainboard: 320*110*32mm
Interface board: 155*30*25mm
Sampling Cable24AWG L=600mm (8S) / 800mm (16S)24AWG L=650mm
NTC24AWG L=650mm24AWG L=650mm
Optional Accessories3.2-inch display screen, 3.5-inch TFT color high-definition screen, 4.3-inch IPS high-definition capacitive touchscreen, Bluetooth module, WiFi module, 4G positioning module, Heating module3.2-inch display screen, 3.5-inch TFT color high-definition screen, 4.3-inch IPS high-definition capacitive touchscreen, Bluetooth module, WiFi module, 4G positioning module, Heating module

Note: Product dimensions are given as length * width * thickness, with a dimensional tolerance range of ±0.5 mm.

4.3 Electrical Parameters (Charge/Discharge & Equalization)

Test ContentDefault Parameters (Li-ion)Default Parameters (LiFePO4)Unit
Rated Discharge Current150/200A
Charge Voltage=4.2*n=3.65*nV
Rated Charging Current150/200A
Balance Turn-on Voltage4.03.4V
Balance Off Voltage4.23.6V
Equalize Opening Voltage Difference20mV
Balance CurrentMax 2000mA

4.4 Protection Parameters

Protection TypeTest ContentDefault ParametersUnit
Single Cell Overcharge Level 1Over-charge alarm voltage4.2±0.05 (Li-ion), 3.6±0.05 (LiFePO4)V
Over-charge alarm delay1±0.8S
Over-charge release voltage4.1±0.05 (Li-ion), 3.5±0.05 (LiFePO4)V
Single Cell Over-discharge Level 1Discharge alarm voltage2.8±0.05V
Discharge alarm delay1±0.8S
Discharge alarm release voltage2.9±0.05V
Short-circuit ProtectionShort-circuit protection current1500/2000A
Short-circuit protection delay300±200uS
Charging High Temperature Level 1High temperature level 1 alarm55±2°C
High temperature level 1 alarm delay1±0.8S
High temperature level 1 alarm release50±2°C
Discharging High Temperature Level 1High temperature level 1 alarm60±2°C
High temperature level 1 alarm delay1±0.8S
High temperature level 1 alarm release55±2°C
Charging Low Temperature Level 1Low temperature level 1 alarm5±2°C
Low temperature level 1 alarm delay1±0.8S
Low temperature level 1 alarm release10±2°C
Discharging Low Temperature Level 1Low temperature level 1 alarm-15±2°C
Low temperature level 1 alarm delay1±0.8S
Low temperature level 1 alarm release-10±2°C

4.5 BMS Dimensions

ComponentDimensions (L*W*H)
BMS Main Board320*110*33 mm

Note: This dimension does not include cables/accessories. Refer to 2D/3D models for detailed installation space.

4.6 Inverter Communication Protocols

Protocol TypeProtocol AbbreviationProtocol NameRemark
RS485 ProtocolSUNSYNK阳光
RS485 ProtocolDEYE德业Support inverter self-identification
RS485 ProtocolPYLON派能Support inverter self-identification
RS485 ProtocolSOROTEC索瑞德
RS485 ProtocolSACOLAR尚科Support inverter self-identification
RS485 ProtocolGROWAT古瑞瓦特Support inverter self-identification
RS485 ProtocolSOFAR首航Support inverter self-identification
RS485 ProtocolSRNE硕日Support inverter self-identification
RS485 ProtocolVOLTRONICPOWER日月元Support inverter self-identification
RS485 ProtocolSTUDER特能
CAN ProtocolSUNSYNK阳光
CAN ProtocolGOODWE固德威
CAN ProtocolDEYE德业
CAN ProtocolXMT
CAN ProtocolSOLARK
CAN ProtocolPYLON派能
CAN ProtocolMEGAREVO迈格瑞能
CAN ProtocolSOROTEC索瑞德
CAN ProtocolSRNE硕日
CAN ProtocolSOLIS锦浪
CAN ProtocolLUXPOWERTEK鹏程
CAN ProtocolSACOLAR尚科
CAN ProtocolGROWAT古瑞瓦特
CAN ProtocolSOFAR首航
CAN ProtocolMUST美克
CAN ProtocolVICTRONENERGY
CAN ProtocolSMA
CAN ProtocolAISWEI爱士惟
CAN ProtocolSTUDER特能

5. Setup Instructions

5.1 Wiring Diagram (Split Type - 100A Active Balancing Example)

Installation Diagram for Split Type BMS
Figure 11: Wiring diagram for a split-type BMS, showing connections for battery pack, sampling cables, display, NTC, inverter, and load.

5.2 BMS Connection Steps

  1. Weld the cable: The first cable (black cable) is connected to the negative terminal of the battery. The second cable (red cable) is connected to the positive terminal of the first string of batteries, and the third cable (red cable) is connected to the positive terminal of the second string of batteries. Continue this pattern until all cables are connected.
  2. Check the cables: After connecting the cables, measure the voltage between two adjacent cables to confirm there are no wrong or missing connections in the cable welding sequence.
  3. Fix the BMS: Secure the BMS, then measure and confirm that the voltage between B- and P- of the BMS is correct. Insert the cable into the BMS.
  4. Plug in the NTC cable: Use the B+ line to connect the positive terminal of the battery pack.
  5. Awaken the BMS: After completing the above steps, the BMS should awaken and work normally. If not, please review and repeat the steps.

5.3 Parallel Communication Wiring Diagram

Parallel Communication Wiring Diagram
Figure 12: Diagram illustrating parallel communication wiring for multiple BMS units connected to an inverter. This example uses a 100A home energy storage BMS (split model).

5.4 Interface Definitions

The BMS features various interfaces for communication and control. Refer to the diagrams below for detailed pinouts and connections.

Interface Schematic Diagram
Figure 13: Overall interface schematic diagram of the BMS main board.

B-/P-/B+ Interface

  • B- Interface: Battery negative terminal. Connects to the battery negative.
  • P- Interface: Protection board charge/discharge negative terminal. Connects to the charging and discharging negative terminal.
  • B+ Interface: Cell/PACK positive terminal. Used to supply power to the BMS. The positive power terminal P+ is directly connected to the positive electrode of the cell.

RJ45 Network Port

The RJ45 single network port integrates RS485 and CAN functions. It allows communication with a host computer to monitor battery information (voltage, current, temperature, status, production info). Default baud rate is 9600bps.

RJ45 Network Port Pinout
Figure 14: Pinout for the external communication (top) and internal communication parallel interface (bottom) RJ45 ports.

Other Interfaces

Includes interfaces for sampling cables, NTC sensors, UART, and optional accessories. Refer to the detailed pinout diagrams in the PDF manual for specific connections.

5.5 Main Cable Description

The main cables included are for B-, C-/P-, B+, NTC, RJ45 (RS485 to USB converter), Key Switch, and Interface Board connection. Ensure to use the correct cables for each connection as specified in the packing list and detailed manual.

5.6 APP Download and Wiring Instructions

For detailed wiring instructions and to download the mobile application, scan the QR code provided in the product packaging or visit the official website: https://www.dalyelec.com/service.html.

6. Operation

6.1 LED Indication

The LED indicators provide visual feedback on the BMS status, including alarm, charging, discharging, and remaining battery power.

StatusRUN LEDAlarm LEDBattery Indicator LEDDescription
Power Off/SleepOffOffAll Off
StandbyFlash 1Off / Flash 3Refer to 6.2Standby state; A level one alarm triggered but no protection activated (if Flash 3)
ChargeOnOff / Flash 3Refer to 6.2Normal charge; Overcharge alarm (if Flash 3)
DischargeFlash 3Flash 3Refer to 6.2Normal discharge; Over-discharge alarm
Failure StateOffOnAll OffSystem in temperature, over-current, short circuit protection, etc. Cannot charge or discharge.

6.2 SOC Indication

Battery SOCChargingDischargingStandby
L4L3L2L1L4L3L2L1L4L3L2L1
0-25%OffOffOffFlash 2OffOffOffOnOffOffOffOn
25-50%OffOffFlash 2OnOffOffOnOnOffOffOnOn
50-75%OffFlash 2OnOnOffOnOnOnOffOnOnOn
75-100%Flash 2OnOnOnOnOnOnOnOnOnOnOn

6.3 Sleep and Wake Up

The BMS can enter sleep mode under specific conditions (e.g., prolonged over-discharge protection, manual button press, or extended inactivity without communication/protection/balancing/current). To wake up the BMS, connect a charger/load, press the reset button, or activate 485/CAN communication.

6.4 Reset Button Functionality

  • From Sleep State: Press and release the button to activate the protection board. The LED indicator will light up sequentially for 0.5 seconds from "RUN".
  • From Active State (Hibernate): Press and hold the button for 3-6 seconds, then release. The protection board will hibernate, and the LED indicator will light up sequentially for 0.5 seconds from the lowest power indicator.
  • From Active State (Reset): Press and hold the button for 6-10 seconds, then release. The protection board will reset, and all LED lights will extinguish.
  • From Active State (Auto-coding): Press the button three times within 5 seconds to automatically re-code the BMS.

6.5 Buzzer Logic

  • Fault: The buzzer sounds for 0.25 seconds every 1 second.
  • Protection: The buzzer sounds for 0.25 seconds every 2 seconds (except for overvoltage protection; for undervoltage, it sounds for 0.25 seconds every 3 seconds).
  • Alarm: The buzzer sounds for 0.25 seconds every 3 seconds (except for overvoltage alarm).

7. Maintenance

7.1 Important Precautions

  1. Voltage Platform Compatibility: Do not mix protection boards from different voltage platforms.
  2. Wiring Compatibility: Wiring from different manufacturers is not common. Ensure to use the matching wiring provided by DALY.
  3. Static Electricity Protection: When testing, installing, touching, and using the protection board, take necessary measures to discharge static electricity.
  4. Heat Dissipation: Do not allow the heat dissipation surface of the protection plate to directly contact the battery. Otherwise, heat will transfer to the battery, affecting its safety.
  5. Unauthorized Modifications: Do not disassemble or change the components of the protection board.
  6. Abnormal Operation: If the protection board operates abnormally, stop using it immediately and only resume use after the issue is resolved.
  7. Correct Polarity: Do not reverse the B- and P- connections, as this may damage the board.

8. Troubleshooting

The DALY Smart Inverter BMS is equipped with various protection mechanisms and indicators to help diagnose issues. Refer to the LED indications and buzzer logic for initial troubleshooting.

8.1 General Fault Conditions

  • Failure State (LEDs Off, Alarm LED On): Indicates the system is in temperature, over-current, or short circuit protection. It cannot charge or discharge. Investigate the cause.
  • Overcharge Alarm (Charging LED On, Alarm LED Flash 3): Unplug the charger.
  • Over-discharge Alarm (Discharge LED Flash 3, Alarm LED Flash 3): Charge the battery.
  • Undervoltage Sleep (Discharge LED Off, Alarm LED Off): Charge the battery to exit this state.

8.2 Buzzer Alerts

The buzzer provides audible alerts for faults, protections, and alarms. Understanding these patterns can help identify the type of issue:

  • Fault: 0.25s sound every 1s.
  • Protection: 0.25s sound every 2s (except overvoltage; undervoltage is 0.25s sound every 3s).
  • Alarm: 0.25s sound every 3s (except overvoltage).

For more detailed troubleshooting, refer to the comprehensive PDF manual available online, which includes specific parameter configurations and system diagrams.

9. User Tips

  • Regular Monitoring: Utilize the self-developed APP or the 3.5-inch HD display to regularly monitor battery status, voltage, current, and temperature. This proactive approach can help identify potential issues early.
  • Proper Ventilation: Ensure the BMS and battery pack are installed in a well-ventilated area to prevent overheating, especially during high charge/discharge cycles.
  • Firmware Updates: Check the DALY official website or APP for any available firmware updates to ensure optimal performance and access to new features.
  • Cable Management: Keep all wiring neat and secure to prevent accidental disconnections or short circuits. Double-check connections periodically.

10. Warranty & Support

10.1 Warranty Information

From the date of purchase, the product is guaranteed free of charge within one year under normal use. Any round-trip freight costs for warranty service will be borne by the user.

10.2 Additional Resources & Support

For a complete user manual and detailed documentation, please refer to the official PDF:

Download User Manual (PDF)

For technical support or inquiries, you may contact DALY at:

Telephone: 0769-82822953

Address: 21/F, building 7, Tian'an Yungu, No. 14, Gongye South Road, Songshanhu District, Dongguan, China