1. Introduction
This high-performance industrial endoscope is equipped with an HD color LCD screen. It is designed to assist with automotive maintenance, pipeline repairs, and other inspection tasks. This efficient tool will help you complete tasks more quickly and discover the microscopic world.
The main unit features an ergonomic design, allowing one-handed operation of the primary function buttons. The adjustable stand on the back frees your hands! The product supports photo and video capture, with files saved to a TF storage card (Micro-SD card). The built-in 2600mAh rechargeable lithium battery provides up to 3 hours of continuous operation.
The camera probe is replaceable, and various specifications for length, diameter, depth of field, and viewing angle are available to meet different inspection and filming scenarios.
Video: Overview and demonstration of the VISHRT Endoscope in use.
2. Safety Warnings
⚠️ Warning! Read all safety warnings and instructions before using this product. Failure to follow the warnings and instructions may result in product damage.
Camera products can only be used for purposes permissible under applicable law and regulations. Misuse of the product for any illegal activities is strictly forbidden. Please comply with the applicable laws and regulations in your country/area.
3. Package Contents
Please check the package contents upon receipt. The exact accessories may vary depending on the lens configuration purchased.

Figure 3.1: Typical package contents including the endoscope unit, camera probe, USB cable, and accessories.

Figure 3.2: Free accessories included with different lens configurations (hooks, magnets, side-view mirrors).
4. Product Overview
Familiarize yourself with the endoscope's components and controls:

Figure 4.1: Endoscope Unit Components
- Camera Probe Interface: Connects the camera probe to the main unit.
- Power Button: Press and hold for 2 seconds to turn on/off. Short press to adjust camera lighting.
- Down/Zoom Out Button: In menu interface, acts as "Down". In image interface, functions as "Zoom Out".
- Up/Zoom In Button: In menu interface, acts as "Up". In image interface, functions as "Zoom In".
- OK/Toggle Button: In menu interface, short press to confirm. Press and hold to switch to the album. In image interface, press and hold to toggle between front and side cameras (dual-camera models only).
- Back/Menu Button: In menu interface, acts as "Back". In image interface, functions as "Menu".
- 180° Image Rotation Button: Click to rotate the live image by 180°.
- Photo/Video Button: Short press to take a photo. Press and hold to record a video; short press again to stop recording.
- Charging Port: Charge the endoscope via a Type-C cable.
- Reset Button: Short press to shut down the device.
- TF Card Slot: Supports TF cards up to 64GB. The TF card is pre-installed; format it before first use.
- Microphone
- Stand
- Speaker
5. Setup
5.1. Charging the Device
- Use a 5V household charger (1A or 2A) that complies with safety regulations to charge the device. Fast charging is not supported.
- The device can be operated while charging.
- The red indicator remains lit during charging and turns off when fully charged.
- If the device is left unused for an extended period, ensure it is charged at least once every 3 months to prevent irreversible damage caused by over-discharging the battery.
5.2. Inserting and Formatting the TF Card
- The endoscope supports TF cards up to 64GB.
- Ensure the TF card is inserted correctly into the TF Card Slot (11).
- Before first use, it is recommended to format the TF card:
- Short press the Menu button (6).
- Navigate to "Format" using the Up/Down buttons (3, 4).
- Select "Format" and confirm with the OK button (5).
5.3. Attaching the Camera Probe
- Connect the camera probe to the Camera Probe Interface (1) on the main unit. Ensure a secure connection.
- The cable is rigid and contains an iron wire, allowing it to be bent and shaped for various inspection angles.
6. Operating Instructions
6.1. Power On/Off
- To turn on the device, press and hold the Power Button (2) for 2 seconds.
- To turn off the device, press and hold the Power Button (2) for 2 seconds. Alternatively, short press the Reset Button (10) to shut down.
6.2. Adjusting Camera Lighting
- Short press the Power Button (2) to adjust the brightness of the LED lights on the camera probe. There are 3 levels of adjustable screen brightness for different scenarios.
6.3. Photo and Video Capture
- To take a photo: Short press the Photo/Video Button (8).
- To record a video: Press and hold the Photo/Video Button (8) to start recording. Short press it again to stop recording.
6.4. Viewing Photos and Videos
- Press and hold the OK button (5) to enter the album.
- Use the Up/Down buttons (3, 4) to browse through photos and videos.
- Press the Menu button (6) again to exit the album.
6.5. Deleting Photos and Videos
- While in the album (see 6.4), press and hold the Menu button (6) to delete the current photo/video or all photos/videos.
- Press the Menu button (6) again to exit the album.
6.6. Image Rotation
- Click the 180° Image Rotation Button (7) to rotate the live image by 180°.
6.7. Zoom Function
- In the image interface, use the Up/Zoom In Button (4) to zoom in and the Down/Zoom Out Button (3) to zoom out. The device supports 3x digital zoom.
6.8. Lens Toggle (for Dual/Triple-Lens Models Only)
- In the image interface, press and hold the OK button (5) to toggle between the main lens, auxiliary lens, and dual-lens modes.
6.9. Waterproof Usage
- The camera lens is IP67 waterproof, allowing it to be submerged up to 1 meter for 30 minutes. This makes it ideal for wet or oily environments.
7. Maintenance
7.1. Battery Care
- To prolong battery life, charge the device fully before first use.
- If the device is not used for an extended period, charge it at least once every 3 months to prevent deep discharge.
- Avoid exposing the device to extreme temperatures, especially cold environments, as this can affect battery performance.
7.2. TF Card Management
- Regularly back up important photos and videos from the TF card to another storage device.
- Format the TF card periodically to maintain optimal performance and free up space.
7.3. Cleaning
- Wipe the screen and device body with a soft, dry cloth.
- For the camera lens, use a soft, lint-free cloth, possibly slightly dampened with lens cleaner, to remove dirt or smudges. Ensure the lens is dry before submerging.
8. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| No Image or Black Screen | Camera probe not properly connected or device malfunction. | Remove and reattach the camera probe, or restart the device. |
| Laggy Image Display | Low battery or connection issue. | Check if the battery is sufficiently charged. Restart the device or reattach the camera probe. |
| Endoscope Won't Turn On | Low battery, especially in cold environments. | Fully charge the endoscope for 4-5 hours and try again. |
| Unable to Take Photos or Videos | TF card not inserted or not formatted. | Ensure the TF card is inserted and formatted before first use. (See Section 5.2) |
| Image Quality Not as Advertised | Incorrect focal distance or insufficient brightness. | Adjust the distance between the camera and the object to the focal range: 40-80mm for single-lens models, or 50-80mm/20-50mm for dual-lens models. Adjust LED brightness for optimal results. |
9. Specifications
| Feature | Specification |
|---|---|
| Display Size | 5-inch IPS Color LCD |
| Screen Resolution | 854 x 480 pixels |
| Photo Resolution | 1920 x 1080 (1080P Full HD) |
| Video Resolution | 1920 x 1080 (1080P Full HD) |
| Camera Options | Single Lens, Dual Lens, Triple Lens, Autofocus Lens |
| Camera Diameter | 3.9mm, 5.5mm, 8mm |
| Viewing Angle (Single Lens) | 70° |
| Viewing Angle (Dual/Triple Lens) | 78° |
| Auxiliary Lighting | Adjustable LEDs (6, 8, 6+1, 8+1, 8+1+1 depending on model) |
| Focal Length (Single Lens) | 20-100mm |
| Focal Length (Dual Lens Front Camera) | 20-150mm |
| Focal Length (Dual Lens Side Camera) | 20-50mm |
| Focal Length (Triple Lens Front Camera) | 20-150mm |
| Focal Length (Triple Lens Side Camera 1 & 2) | 20-50mm |
| Focal Length (Autofocus Lens) | 2cm~∞ (automatically adjusts) |
| Cable Type | Rigid Cable (with internal iron wire) |
| Cable Length Options | 1m, 2m, 3.5m, 5m, 10m, 15m |
| Waterproof Rating | IP67 (lens only, submersible up to 1m for 30 minutes) |
| Digital Zoom | 3x |
| Battery Capacity | 2600mAh |
| Battery Life | Approx. 3 hours (3-5 hours stated in description) |
| Charging Time | Approx. 2 hours |
| Power Input | DC 5V 500mA/1A |
| Operating Temperature | 0°C to 45°C |
| Image Format | JPG |
| Video Format | MP4 |
| TF Card Support | Up to 64GB (not included with all models) |
10. User Tips
- The resolution and picture quality are generally very impressive, making it a handy tool for various inspections.
- For fixed-focus lenses (Single, Dual, Triple), keep the target object approximately 4-10cm (front camera) or 2-6cm (side camera) from the lens for the sharpest image. The resolution may decrease if the distance is too far or too close.
- The device is well-built and easy to use, making it a helpful addition to any toolbox.
- The screen quality is good, providing vivid colors and a wide viewing angle.
11. Warranty and Support
For detailed warranty information and customer support, please refer to the official product page or contact the seller directly. A user manual in PDF format is available for download at: User manual (PDF).