DALY Smart BMS 4S-24S

Contents

DALY Smart BMS User Manual

Model: Smart BMS 4S-24S

1. Introduction

This manual provides essential information for the safe and efficient operation of your DALY Smart Battery Management System (BMS). Please read this manual thoroughly before installation and use to ensure optimal performance and longevity of your battery pack.

Play video
Watch video online

Video: DALY Smart Active Balance BMS overview, demonstrating balancing and key features.

2. Safety Information

  • Sampling Cables: Cables from different manufacturers are not universal. Always use the provided sampling cables from DALY.
  • Anti-Static Measures: When testing, installing, contacting, and using the BMS, anti-static measures must be taken to prevent damage.
  • Heat Dissipation: Do not allow the heat dissipation surface of the BMS to directly contact the battery cell. Direct contact will transfer heat to the battery cell, potentially affecting battery safety.
  • No Disassembly: Do not disassemble or change the components of the BMS yourself. Unauthorized modifications can void the warranty and lead to malfunction.
  • Electrical Conductivity: The outer shell of the BMS conducts electricity. Avoid contact with the battery cell and nickel strip during assembly operations due to the electrostatic protection design. The shell and motherboard share the same ground, and it is normal for voltage to appear during measurement.
  • Environmental Conditions: All products undergo strict ex-factory inspection. Ensure the BMS is used according to parameter instructions and avoid high or ultra-low temperature environments (normal applicable temperature: -40°C to 85°C) to prevent failure.

3. Product Overview

The DALY Smart BMS is an intelligent active balance battery management system designed for various battery chemistries including LiFePO4, Li-ion, and LTO. It features built-in Bluetooth for APP control, and supports multiple communication interfaces like UART, CANBUS, and RS485.

DALY Smart BMS main unit

Image: Main product view of the DALY Smart BMS.

3.1. Packing List

Upon unpacking, please verify that all items are present:

  • Smart Active Balance BMS unit
  • P-&B-cable
  • Screws
  • Sampling cable
  • B+ cable
  • Key switch cable
  • NTC (Negative Temperature Coefficient) sensor
  • User Manual (this document)
  • Packaging box
Packing list for DALY Smart BMS

Image: Visual representation of the DALY Smart BMS packing list, including the BMS unit, various cables, screws, NTC sensor, and user manual.

4. Specifications

4.1. General Specifications

Index Specification
Battery pack type Li-ion, LiFePO4, LTO
Number of battery strings Li-ion: 4-8S/8-17S/8-20S
LiFePO4: 4-8S/8-17S/8-24S
LTO: 6-8S/8-17S/8-24S
Cell sampling voltage range 1.5V-4.9V
Operating voltage range > 10V
Balance method Active Balance
Working power consumption <1.25W
Sleep current ≤0.025W
Working temperature -40°C - 85°C
Indicator light Green: works properly
Red: Alarm or protection

4.2. Model-Specific Dimensions and Current Ratings

Product Specification table with dimensions and continuous current ratings for various DALY Smart BMS models (40A-500A)

Image: Detailed specifications for different DALY Smart BMS models, including sustained current, number of strings, size, and weight. Data tolerance range ±0.5mm.

Detailed product specification for 40A/60A DALY Smart BMS model

Image: Specific dimensions and weight for the 40A/60A DALY Smart BMS model (125*66*15.8mm, 177g).

Small size and flexible installation of DALY Smart BMS

Image: Illustrates the compact size of the BMS (125mm x 65mm x 14mm) and its universal compatibility for 4-24S battery configurations.

4.3. Product Parameters

Table of DALY Smart BMS product parameters

Image: Table detailing battery compatible strings, discharge/charging currents, overcurrent protection values, active balance function parameters (turn-on voltage, pressure difference, balance current), short circuit protection conditions, and communication methods (UART, RS485, CAN, Bluetooth, GPS, LCD, SOC display module).

Table of DALY Smart BMS advanced features and options

Image: Table outlining activation voltage settings, balancing current, communication interfaces, parallel function, APP default parameters, and optional modules like WiFi, GPS, Display, Pre-Charge, Heating, and Key Switch.

5. Installation and Wiring

5.1. Wiring Precautions

  • Pay close attention to the positions of B- and P- on the BMS. Connect wires strictly according to B- to the total negative terminal of the battery and P- to the negative terminal of the load or charger.
  • When soldering wires, ensure they are soldered in the correct order before plugging into the BMS. Miswiring protection is limited to 6 strings; more than 6 strings of miswiring will damage the BMS.
  • Weld the sampling cables to the battery pack. If using an incomplete string configuration (e.g., a 4-string battery with an 8-string BMS), wrap the extra cables for insulation treatment. Follow the wiring sequence strictly; reversing it will damage the BMS.

5.2. Power-On Sequence

  1. Install B-
  2. Insert the collection line
  3. Connect the B+ line
  4. Install P-

5.3. Power-Off Sequence

  1. Remove B+ cable
  2. Remove collection cable
  3. Remove B-
  4. Remove P-

5.4. NTC Cable Connection

The NTC cable needs to be plugged into the NTC-1 or NTC-A port first.

5.5. Wiring Diagrams

Wiring diagram for 4-8 strings DALY Smart BMS

Image: Wiring diagram for 4-8 strings BMS, showing connections for load, charger, B+ total positive electrode, and B- total negative pole. Note: The extra 4 cables must be wrapped for insulation treatment if using a 4-string battery with an 8-string BMS.

Wiring diagram for 7-24 strings DALY Smart BMS

Image: Wiring diagram for 7-24 strings BMS, illustrating connections for load, charger, B+ total positive electrode, and B- total negative pole. BMS requires initial charging to activate upon first installation. Default parameters are for LiFePO4; Li-ion/LTO parameters can be switched via the App. The wiring diagram uses the AK BMS as an example; others are the same. The matching rule for red wiring harnesses to the number of battery strings is: number of cables = number of battery strings + 1 (with 1 black wire designated as B0). Taking a 24-string battery as an example: 25 cables correspond to 24 strings, 17 cables correspond to 16 strings, and other string counts follow this pattern by analogy. If using an 8-string battery, connect 9 cables (including 1 B0 black wire), leave the remaining cables unconnected, and ensure proper insulation treatment for the excess sampling wires.

Wiring diagram for 8-24 strings DALY Smart BMS

Image: Wiring diagram for 8-24 strings BMS, showing connections for load, charger, B+ total positive electrode, and B- total negative pole. Please refer to the user manual for detailed information.

Wiring diagram for 8-17 strings DALY Smart BMS

Image: Wiring diagram for 8-17 strings BMS, showing connections for load, charger, B+ total positive electrode, and B- total negative pole. Please refer to the user manual for detailed information.

6. Operating Instructions

6.1. APP and PC Software Installation

  1. Scan QR Code: Scan the QR code provided on the BMS unit or in the manual to download the APP.
  2. Search APP: Search for "DALY BMS" in the iOS App Store or Google Play Store.
  3. PC Software: Scan the QR code to download the PC Master software.
DALY Smart BMS communication and management options

Image: Overview of communication and management options including PC Host, Bluetooth APP, GPS module, and IoT Cloud.

6.2. Parameter Settings

  • When using the BMS for the first time, the battery type and capacity need to be set in the APP or PC software. The factory default is LFP parameters.
  • The capacity of the battery pack needs to be set according to the actual capacity of the battery pack.
  • The battery needs to be fully charged (100%) for calibration during the first use.
  • Other protection parameters can be set according to your specific needs.
  • The factory default password for modifying parameters on the APP is 123456.
  • The factory default password for modifying parameters on the PC host is 20211115.

6.3. Active Balance Function

The BMS features an active balance function to equalize cell voltages. Balance occurs when:

  • The set balance on voltage is reached (default: 3V).
  • The set balance on voltage difference is reached (default: 10mV).

If either condition is not met, balancing will be paused. The balance current is typically 900±200mA.

DALY Smart BMS with 1A Active Balance feature

Image: Highlights the 1A Active Balance feature, suitable for 4-24S strings with 40-200A continuous current, ensuring efficient, safe, and intelligent battery management.

7. Maintenance

  • Environmental Protection: Ensure the BMS is protected from water and moisture. Maintain proper insulation around the battery pack and BMS.
  • Temperature: Operate the BMS within the specified working temperature range of -40°C to 85°C.
  • Firmware Updates: Regularly check for firmware updates via the APP or PC software to ensure optimal performance and access to new features.

8. Troubleshooting

  • BMS Sleep Mode: When there is no charging or discharging, the BMS will enter sleep mode after 3600 seconds by default. It will wake up automatically when charging or discharging is detected. The sleep time can be modified via the APP or PC. Setting it to 65535 means no sleep.
  • Indicator Light: A green indicator light means the BMS is working properly. A red indicator light indicates an alarm or protection event.
  • Voltage Measurement: Use a multimeter or line sequence detection equipment to measure whether the voltage of each string of pinholes in the cable is within the normal range. If not, check for misconnections, false soldering, or missing soldering in the wiring.
  • Parallel Connection Issues: Ensure battery pack voltages are the same when connecting in parallel. A total pressure difference of <1V is recommended to prevent high-current charging from a high-voltage pack to a low-voltage pack, which can trigger BMS short-circuit protection.
  • Parallel Connection with Discharging MOS: When paralleling lithium battery packs, manually disconnect the discharging MOS in the Bluetooth APP control center interface before paralleling to prevent battery packs from firing.

9. User Tips

  • For initial setup, ensure your battery pack is fully charged for accurate calibration of the BMS.
  • Utilize the Bluetooth APP for convenient monitoring and adjustment of parameters.
  • Always double-check all wiring connections before powering on the system to prevent damage.

10. Frequently Asked Questions (FAQ)

Q: What is the default password for the APP and PC host?
A: The default password for modifying parameters on the APP is 123456. For the PC host, it is 20211115.
Q: How do I activate the BMS?
A: After connecting all accessories and sampling cables, insert the sampling cable into the BMS to activate it automatically.
Q: Can I use sampling cables from another brand?
A: No, cables from different manufacturers are not universal. Always use the sampling cables provided by DALY.

11. Warranty and Support

For any technical assistance, warranty claims, or further inquiries, please contact the DALY customer support team or refer to the official DALY website: www.dalybms.com.

A user manual in PDF format is available for download: Download User Manual (PDF).

© 2024 DALY. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.