MYOSLIM CO2 Fractional Laser System

Contents

MYOSLIM CO2 Fractional Laser System

User Manual

Model: CO2 Fractional Laser System | Brand: MYOSLIM

1. Introduction

The MYOSLIM CO2 Fractional Laser System is a cutting-edge skincare tool designed to rejuvenate and improve skin with advanced laser technology. It utilizes a unique dot matrix system to stimulate collagen production for smoother, firmer skin and treats a variety of skin concerns. This device is suitable for both professional and at-home use, offering a non-surgical solution to enhance skin quality.

It is ideal for addressing fine lines, wrinkles, pigmentation, acne scars, enlarged pores, stretch marks, and for skin resurfacing, scar revision, syringomas, and blepharoplasty. The system features an imported laser arm with three working modes: Fractional, Normal, and Vaginal, ensuring a 360° treatment with the highest energy output and minimal energy loss.

2. Safety Information

WARNING: This device is not intended for medical supervision. Always consult with a qualified professional before use, especially for sensitive areas or pre-existing skin conditions.

  • Ensure the device is properly grounded before use.
  • Do not operate the device if any part is damaged or malfunctioning.
  • Keep the device away from water and other liquids.
  • Wear appropriate protective eyewear during operation to prevent eye injury from laser exposure.
  • Keep out of reach of children.
  • Do not use on irritated, broken, or infected skin.
  • Avoid direct eye contact with the laser beam.
  • Ensure adequate ventilation during operation.

3. Package Contents

Please check the package carefully to ensure all items are present and undamaged.

  • CO2 main unitCO2 Main Unit: The primary control and power unit of the laser system.
  • Guide light armGuide Light Arm: Articulated arm for precise laser delivery.
  • Fractional laser head and other accessoriesFractional Laser Head: For skin resurfacing and scar treatment.
  • Vaginal tightening headVaginal Tightening Head: Specialized head for vaginal rejuvenation treatments.
  • Pulse headPulse Head: For specific pulse mode treatments.
  • Key for device operationKey: For turning the device on/off and security.
  • Foot switch for hands-free operationFoot Switch: For hands-free operation during treatment.
  • Power cordPower Cord: To connect the device to a power source.

4. Specifications

FeatureSpecification
Wavelength10600nm
Laser ApparatusSealed off laser device simulated by direct current
Optical Beam QualityTEMOO
Output Power40W
Spot Size0.02~0.05mm²
Aiming BeamRed semiconductor laser (635nm, less than 5mw)
Beam Transport DeviceArticulated arm with 7-joint and balance weight
Working ModeContinuous operation
Output ModeContinuous, single pulse, interval pulse and super pulse
Scan ScopeMax 20mmx20mm
Scan GraphicsCircle, triangle, square, rectangle, hexagon, ellipse, line
Scanning ModeRandom, Normal and Midsplit scan
Scanning SpeedMore than 10m/s
Energy1-40W
Distance0.1-2.6mm
Cooling SystemAir circulation
Power Input220V/110V
Maximum Power Consumption2.3kVA
Output Power6500W
MaterialMetal
CertificationCE, ROHS
Treatment AreaButtocks, thighs, hips, arms, ABS (and face, vaginal, vulva)
EffectReduced fat by 21%, Increased muscle mass by 16% (Note: These effects are typically associated with body contouring, not CO2 laser. Please verify with manufacturer.)
Contraction (30 min)More than 20000 times
ApplicationFor Commercial

5. Setup Instructions

5.1 Initial Assembly

  1. Install the Arm: Carefully install the guide light arm into the base unit.
  2. Connect Scan Head: Connect the desired scan head (e.g., fractional laser head) to the guide light arm.
  3. Connect Power & Foot Switch: Connect the power cord to the main unit and a suitable power outlet. Connect the foot switch to its designated port on the main unit.

5.2 Water Filling

Before first use, or if the water level is low, add distilled water to the cooling system.

  1. Locate the water inlet port on the back of the main unit.
  2. Using a funnel, slowly add approximately 5 liters of distilled water into the system until the water level indicator shows full.
  3. Ensure no water spills onto the device.
Video: Demonstrates the water filling process for the CO2 Fractional Laser System. A person is shown pouring water into the designated inlet on the back of the machine using a funnel.

6. Operating Instructions

6.1 Power On and Main Screen

  1. Turn On: Insert the key into the key switch and turn it to the ON position.
  2. Main Screen: The main screen will appear on the display. From here, you can select the desired treatment mode.
Main unit with display showing treatment options
Image: The main unit of the CO2 Fractional Laser System, displaying the touch screen interface with various treatment options and settings.

6.2 Face Treatment (Lattice Mode)

This mode is used for general facial skin concerns like fine lines, wrinkles, and acne scars.

  1. From the main screen, select the

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.