MYOSLIM CO2 Fractional Laser Machine

Contents

MYOSLIM CO2 Fractional Laser System User Manual

Model: CO2 Fractional Laser Machine

1. Product Overview

The MYOSLIM CO2 Fractional Laser System is a versatile and powerful professional workstation designed for a comprehensive range of aesthetic and therapeutic concerns. It combines a 10,600nm wavelength with advanced fractional scanning, precise cutting, and specialized intimate applications for skin revitalization, scar revision, and vaginal tightening.

MYOSLIM CO2 Fractional Laser System main unit

Figure 1: MYOSLIM CO2 Fractional Laser System

1.1 Key Features

  • Multifunctional System: Integrates Fractional Resurfacing, Surgical Cutting, and Vaginal Rejuvenation modes.
  • High-Precision Scanning Head: German-imported, ensuring long lifespan, deep & accurate energy penetration, strong output, and minimal failure rate.
  • High-Power Output: 60W output with a 360° articulating arm for stable, high-energy delivery and operational flexibility.
  • Multi-Dimensional Lattice Technology: Creates microscopic treatment zones (MTZs) for targeted ablation and coagulation.
  • Versatile Treatment Probes: Includes dedicated fractional, cutting, and vaginal probes.
  • Integrated Cooling System: Improves patient comfort and protects the epidermis.
  • No Melanin Precipitation: 10,600nm wavelength is safe for all skin types with reduced risk of dyspigmentation.
CO2 Laser Product Features: Remove acne marks, stretch mark removal, mole removal, tighten vagina

Figure 2: Product Features and Applications

2. Accessories List

The following items are included with your CO2 Laser System:

Item Description
CO2 main unit The primary laser system console.
Guide light arm Articulated arm for precise laser delivery.
Power cord For connecting the unit to a power source.
Key Security key for operating the machine.
Foot switch For activating the laser during treatment.
Fractional laser head Handpiece for fractional resurfacing treatments.
Vaginal tightening head Specialized probe for vaginal rejuvenation.
Pulse head Handpiece for pulse mode treatments.

3. Specifications

Parameter Value
Wavelength 10600nm
Laser apparatus Sealed off laser device simulated by direct current
Optical beam quality TEM00
Output power 40W (up to 60W mentioned in description)
Spot size 0.02~0.05mm²
Aiming beam Red semiconductor laser (635nm, less than 5mw)
Beam transport device Articulated arm with 7-joint and balance weight
Working mode Continuous operation
Output Mode Continuous, single pulse, interval pulse and super pulse
Scan scope Max 20mmx20mm
Scan graphics Circle, triangle, square, rectangle, hexagon, ellipse, line
Scanning Mode Random, Normal and Midsplit scan
Scanning speed More than 10m/s
Energy 1-40W
Distance 0.1-2.6mm
Cooling system Air circulation
Power 220V/110V
Material ABS+Steel
Style PORTABLE

4. Setup and Installation

Follow these steps to set up your CO2 Fractional Laser System:

  1. Install the guide light arm securely into the base of the main unit.
  2. Connect the scan head to the appropriate port on the main unit.
  3. Connect the power cord to the machine and a suitable power outlet (220V/110V).
  4. Connect the foot switch to its designated port.
  5. Add enough water (approximately 5 Liters) to the cooling system. Ensure the water level is adequate before operation.
Rear view of the CO2 Fractional Laser System showing connections

Figure 3: Rear connections of the main unit

Video 1: Demonstrates machine startup and fractional laser test on paper.

5. Operating Procedures

This section details the operation of the CO2 Fractional Laser System for various treatment modes.

5.1 General Operation

  1. Turn on the machine using the key switch.
  2. The main screen will appear, displaying various treatment modes.
  3. Select the desired mode (Normal, Fractional, 3D, 4D, Vulvae) and adjust parameters as needed.
  4. Operate the laser by stepping on the foot switch after completing all procedure settings.

5.2 Face Treatment (Lattice Mode)

This mode is used for skin resurfacing, wrinkle reduction, and scar revision.

  1. From the main screen, select the 'Fractional' or '2D Fractional' option to enter the treatment interface.
  2. Adjust parameters using the touch screen:
    • LASER POWER: 1-30W. Use '+' or '-' to adjust.
    • RESIDENCE TIME: 0.1-10.0ms.
    • POINTS: 1-5000ms.
    • ROW SPACING: 0.1mm-2.6mm.
    • SCAN MODE: Midsplit, Sequence, Disorder.
    • SCAN TIMES: 1-5th.
  3. Select the desired scan shape (Square, round, triangular, hexagonal, straight) from the options.
  4. Adjust the shape size and preview it to ensure suitability.
  5. Once parameters are set, press "Ready" and then use the foot switch to activate the laser.
  6. To return to the main screen, touch "BACK".

Recommended Parameters for Face Treatment:

Parameter Skin Peeler Striae Gravidarum Depressed Scar Flat Scar Raised Scar Acne
Shape Square Square Uncertain Uncertain Uncertain Uncertain
Shape size 20 20 Uncertain Uncertain Uncertain Uncertain
POWER W 5~6 15~20 8~10 7~8 15~20 8~10
RESIDENCE TIME ms 1 1 1 1 1 1
INTERVAL TIME ms 1 1 1 1 1 1
POINT SPACING mm 1 1 1 1 1 1
SCAN MODE Random Random Random Random Random Random

5.3 3D Mode (Pulse Mode)

This mode is used for specific pulsed laser applications.

  1. From the main screen, select the '3D' option to enter the PULSE MODE interface.
  2. Adjust parameters using the touch screen:
    • POWER: 1-30W.
    • MODE: Adjust impulse, continue, single, etc.
    • POINT STAY: 1-5000ms.
    • PULSE WIDTH: 1-10ms.
    • INTERVAL: 1-10ms.
  3. Once parameters are set, press "Ready" and then use the foot switch to activate the laser.

Recommended Parameters for 3D Mode:

Parameter Value
SCAN TIMES th 1
Courses Uncertain
Interval of courses 1 month

5.4 4D Mode

This mode is similar to the Lattice Mode for face treatment, offering advanced fractional settings.

  1. From the main screen, select the '4D' option.
  2. Adjust parameters (LASER POWER, RESIDENCE TIME, POINTS, ROW SPACING, SCAN MODE, SCAN TIMES) as described for Face Treatment.
  3. Select desired scan shape and size.
  4. Press "Ready" and use the foot switch to activate.

5.5 Vagina Treatment (Private Mode)

This mode uses a specialized vaginal probe for rejuvenation.

  1. From the main screen, select the 'Private Mode' option.
  2. Adjust parameters (LASER POWER, RESIDENCE TIME, POINTS, ROW SPACING, SCAN MODE, SCAN TIMES) as described for Face Treatment.
  3. Insert the support into the vagina.
  4. Insert the 360-degree head to the bottom of the support.
  5. Pay attention to the number on the 360-degree head.
  6. Press the foot switch, then pull out 0.5cm. Repeat this step three times.
  7. After the 360-degree head reaches the vulva, insert it to the bottom of the support again and repeat the process three times.
Diagram of vaginal probe and tightening mechanism

Figure 4: Vaginal probe and treatment mechanism

5.6 Vulva Treatment (Vulvae Mode)

This mode is for vulva treatment.

  1. From the main screen, select the 'Vulvae Mode' option.
  2. Adjust parameters (POWER, RESIDENCE TIME, INTERVAL TIME, POINT SPACING, SCAN MODE, SCAN TIMES).
  3. Use the vulva head, maintaining a distance of 5cm.
  4. Treat the vulva by pressing the foot switch multiple times until the vulva tightens up.

5.7 General Operation Steps for Vagina Treatment

Preparation:

  • Alcohol
  • Cotton ball
  • Sterile treatment head

Operation:

  1. Clean the treatment area with alcohol and a cotton ball.
  2. Insert the vaginal probe carefully.
  3. Follow the specific instructions for Vagina Treatment (Private Mode) or Vulva Treatment (Vulvae Mode) as described above.

Postoperative Care and Notes:

  • Pay attention to genital health after surgery.
  • Ensure adequate rest.
  • Avoid intimate activity for one week post-treatment.

6. Maintenance

Proper maintenance ensures the longevity and optimal performance of your CO2 Fractional Laser System:

  • Cleaning: Wipe handpieces with alcohol wipes after each use to maintain hygiene and prevent residue buildup.
  • Water Level: Regularly check and maintain the water level in the cooling system. Ensure it is always sufficient for operation.
  • Storage: Store the machine in a clean, dry environment when not in use.
  • Professional Service: For any complex issues or routine checks, contact qualified technical support.

7. Troubleshooting

If you encounter any issues with your CO2 Fractional Laser System, please refer to the following common problems and solutions:

  • Machine Not Powering On:
    • Ensure the power cord is securely connected to both the machine and the power outlet.
    • Check if the key switch is turned to the 'ON' position.
    • Verify the power outlet is functional.
  • Laser Not Firing:
    • Confirm that all parameters are correctly set for the selected treatment mode.
    • Ensure the 'Ready' button (or equivalent) has been pressed on the touch screen.
    • Check if the foot switch is properly connected and being pressed firmly.
    • Verify that the water level in the cooling system is adequate.
  • Abnormal Screen Display:
    • Restart the machine. If the issue persists, contact technical support.

For persistent issues or problems not listed here, please contact our technical support team.

8. User Tips

  • Pre-Treatment Consultation: Always conduct a thorough consultation to determine the most suitable treatment mode and parameters for each client's skin type and concerns.
  • Parameter Adjustment: Start with lower energy settings and gradually increase as needed, observing the client's skin response.
  • Safety First: Ensure proper eye protection for both the operator and the client during all laser procedures.
  • Post-Treatment Care: Advise clients on appropriate aftercare, including sun protection and moisturizing, to optimize results and minimize side effects.
  • Training: Utilize the provided user manual and online training resources to fully understand the machine's capabilities and safe operation.

9. Frequently Asked Questions (FAQ)

Q1: Is this machine safe for all skin types?
A: Yes, the fractional CO2 laser uses 10,600 nm wavelength which is safe for all skin types with minimal risk of pigmentation.
Q2: What is the recovery time after treatment?
A: Most clients experience 3–5 days of redness and slight peeling. Full recovery typically within 7–10 days depending on treatment depth.
Q3: Can I use it for under-eye wrinkles?
A: Yes, with fractional mode and low energy settings, it is safe for periocular areas.
Q4: How many sessions are needed for acne scars?
A: Usually 3–5 sessions spaced 4–6 weeks apart for optimal improvement.
Q5: Is the vaginal probe safe and effective?
A: Yes, it uses controlled thermal energy to stimulate collagen without damaging surrounding tissue. Results improve over 1–3 sessions.
Q6: What is the lifespan of the laser tube?
A: The imported German laser tube is designed for long-term use with unlimited shots under normal operating conditions.
Q7: Can I treat stretch marks on the body?
A: Yes, both fractional and cutting modes can be used on stretch marks on abdomen, thighs, and arms.
Q8: How do I clean the handpieces?
A: Wipe handpieces with alcohol wipes after each use.

10. Warranty and Support

  • Warranty: We offer a 1-year warranty on the main unit and 6 months on handpieces.
  • After-sales Service: Free spare parts, video technical support, and online support are provided.
  • Technical Support: A professional technology supporting team is available for timely services via telephone, webcam, or online chat.
  • Repair Centers: Dual repair centers in Mexico and Europe offer faster overseas local after-sales service, reducing international shipping costs and repair times.
  • User Manual: A complete user manual for instruction and application is provided.

For further assistance, please refer to the official user manual PDF: View User Manual (PDF)

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.