1. Introduction
This manual provides detailed instructions for the installation, operation, and maintenance of your meterk 1/8NPT Thread Stainless Steel Pressure Transducer Sensor. This advanced pressure transducer offers stable and accurate performance, designed to replace traditional mechanical pressure transducers directly.
It is suitable for measuring pressure in various media including oil, fuel, diesel, gas, water, and air, making it ideal for applications in oil tanks, gas tanks, diesel tanks, hydraulic systems, HVAC, and constant pressure water supply systems.
2. Safety Warnings
- WARNING: To avoid danger of suffocation, keep any plastic packaging away from babies and children.
- Ensure proper electrical connections to prevent short circuits or damage to the sensor and connected equipment.
- Do not exceed the rated pressure or operating temperature limits specified for your sensor model.
- Installation should be performed by qualified personnel familiar with pressure systems and electrical wiring.
3. Specifications
The meterk pressure transducer is designed for high accuracy and durability. Key features include a small output error (±2%FS), complete surge voltage protection, and compatibility with various media.
| Feature | Description |
|---|---|
| Material | Stainless steel (compatible with 316L stainless steel for pressure medium) |
| Voltage | DC 5V |
| Thread Type | 1/8" NPT (1/8"-27 NPT for 30PSI, 100PSI, 200PSI) |
| Output | 0.5V~4.5V linear voltage output |
| Protection Class | IP67 |
| Explosion-proof Class | ExiaTTCT6 |
| Response Time | ≤1ms |
| Insulation Resistance | >100mΩ 500VDC |
Pressure Range Specifics
| Pressure (PSI) | Input Range | Accuracy | Working Temp. | Overload Capacity |
|---|---|---|---|---|
| 30 | 0-30 psi | within 2% FS | -40℃~+120℃ | 2-4 times |
| 100 | 0-100 psi | within 2% FS | -40℃~+120℃ | 2-4 times |
| 150 | 0-150 psi | +/-0.5%FS | -40℃~+120℃ | 2-4 times |
| 200 | 0-200 psi | ±1%FS | -40℃~+125℃ | 2 times |
| 300 | 0-300 psi | +/-0.5%FS | -40℃~+120℃ | 2-4 times |
| 500 | 0-500 psi | +/-1%FS | -40℃~+120℃ | 2-4 times |
4. Installation
The pressure transducer is designed to be lightweight and small, making it convenient to install. It can directly replace mechanical sensors.
- Preparation: Ensure the system is depressurized and de-energized before installation.
- Mounting: Thread the sensor into the appropriate 1/8" NPT port. Use thread sealant if necessary to ensure a leak-free connection. Do not overtighten.
- Orientation: The sensor can be installed in any orientation, but ensure the wiring connector is accessible for connection.
5. Wiring Instructions
The transducer comes with a water-sealed quick disconnect mating connector and wire harness (pigtail). Ensure correct wiring to prevent damage and ensure accurate readings.
Standard Wiring Color Code:
- Red Wire: +5V (Power Supply Input)
- Black Wire: Ground
- Blue/Green/Yellow Wire: Signal Output (Specific color may vary by PSI range, refer to the table below)
| Pressure (PSI) | Red | Black | Signal Output |
|---|---|---|---|
| 30 | +5V | Ground | Blue |
| 100 | +5V | Ground | Blue |
| 150 | +5V | Ground | Green |
| 200 | IN+ | GND | OUT (Green) |
| 300 | +5V | Ground | Green |
| 500 | +5V | Ground | Yellow (Green) |
Connect the signal output wire to your data acquisition system or display unit. The output is a linear voltage from 0.5V (0 psi) to 4.5V (full scale pressure).
6. Operation
Once installed and wired correctly, the pressure transducer will provide a linear voltage output corresponding to the measured pressure. This sensor features complete surge voltage protection for enhanced reliability.
- Power On: Apply DC 5V power to the red (+5V) and black (Ground) wires.
- Read Output: Monitor the voltage on the signal output wire (Blue/Green/Yellow).
- Interpretation: The output voltage scales linearly with pressure. For example, a 150 PSI sensor will output 0.5V at 0 PSI, 2.5V at 75 PSI, and 4.5V at 150 PSI.
7. Maintenance
The meterk pressure transducer is designed for stable performance and long-term reliability with minimal maintenance.
- Regular Inspection: Periodically check the sensor and wiring for any signs of physical damage, corrosion, or loose connections.
- Cleaning: If necessary, gently clean the exterior of the sensor with a soft, damp cloth. Avoid using harsh chemicals or abrasive materials.
- Pressure Medium: Ensure the pressure medium remains compatible with 316L stainless steel to prevent sensor degradation.
- Calibration: While designed for stable performance, periodic calibration checks may be performed by qualified technicians if high precision is critical for your application.
8. Troubleshooting
If you encounter issues with your pressure transducer, consider the following common troubleshooting steps:
- No Output/Incorrect Reading:
- Verify the 5V DC power supply is correctly connected (Red to +5V, Black to Ground).
- Check all wiring connections for looseness or damage.
- Ensure the sensor is correctly threaded and sealed in the pressure port.
- Confirm the pressure medium is within the sensor's specified range.
- Check for blockages in the pressure port or sensor inlet.
- Unstable Output:
- Check for electrical noise in the environment. Ensure proper shielding if necessary.
- Verify the power supply is stable and free from fluctuations.
- Inspect for vibrations in the system that might affect readings.
- Leakage:
- Ensure the thread sealant (if used) is appropriate and applied correctly.
- Check for proper tightening of the sensor into the port.
9. User Tips
- For critical applications, consider using a multimeter to verify the sensor's output voltage at known pressure points during initial setup.
- When replacing a mechanical sensor, ensure the new electronic transducer's pressure range matches or exceeds the requirements of your application.
10. Manufacturer & Support Information
Manufacturer:
- Company Name: Dongguan Wanbaole Industrial Co., Ltd
- Address: No. 11, Lane 18, Haoxiajiao District 1, Wanjiang Street, Dongguan City, Guangdong Province
- Email: a213sumaitn2925@163.com
- Telephone: 86-17776659325
EU Authorized Representative:
- Company Name: SOLID AUTHORITY LIMITED
- Address: IE-51 BRACKEN ROAD, Sandyford, Dublin 18, Ireland
- Email: phoebe8706@gmail.com
- Telephone: 33-761441379