MILESEEY TR10

Rate this product if you’ve used it
Contents

MILESEEY TR10 Thermal Camera User Manual

Model: TR10

Introduction

Thank you for your purchase of the MILESEEY TR10 handheld infrared thermal camera. This manual provides detailed instructions for optimal use, understanding, and maintenance of your device. The TR10 is designed to enhance efficiency in maintenance and inspection tasks, offering accurate and user-friendly temperature detection.

MILESEEY TR10 Thermal Camera front view
MILESEEY TR10 Thermal Camera

Safety Instructions

To ensure your safety and the accuracy of measurements, please adhere to the following guidelines:

  • General Use: Use this product strictly according to the guidelines provided in this user manual. Failure to adhere to these instructions may lead to damages not covered under warranty.
  • Cleaning: Gently wipe the exterior with a damp cloth or a mild soap solution. Avoid abrasive cleaners, isopropyl alcohol, or any solvents on the casing, lens, and windows, as these can cause damage.
  • Environment: Avoid operating this product in flammable, explosive, high steam, high humidity, or corrosive environments. Such conditions can impair performance and pose safety risks.
  • Damage: Cease using the product immediately if it becomes damaged, has been dropped, or has been modified. Continued use under these conditions may lead to inaccurate measurements and compromise safety.
  • Emissivity: Adjust the correct emissivity for the target material to obtain accurate temperature readings.
  • Charging: The internal temperature may increase during charging, affecting measurement accuracy. Do not perform measurements while charging or immediately after.
  • Warm-up: If the device has not been used for a long time, allow it to warm up for 2 minutes before use to maintain measurement accuracy.

Product Overview & Key Features

The MILESEEY TR10 is a handheld infrared thermal camera designed for efficiency and precision. Its key features include:

  • 2.8-Inch Color LCD Display: Offers an expansive viewing area for easy identification and analysis of fault zones.
  • Adjustable Emissivity: Allows for personalized settings to refine detection accuracy based on different materials.
  • Image Capture and Storage: Built-in 8GB memory stores up to 30,000 images with temperature data for comprehensive analysis.
  • Convenient Data Transfer: USB connection for quick export of images to PC.
  • Integrated Lithium Battery: Built-in battery with a TYPE-C charging interface for simplified charging and data transfer.
  • Automatic Hot and Cold Spot Tracking: Identifies and locks onto the highest and lowest temperature points, enhancing diagnostic capabilities.
  • Cross-hair Display: For easy targeting of the measuring spot.
  • Customizable Temperature Alarms: Set individual high and low temperature alarms for immediate attention to critical areas.
  • Extensive Temperature Range: Measures temperatures up to 550°C (1022°F), suitable for various industrial applications.
  • Portable and User-Friendly Design: Ideal for professionals in maintenance and inspection.
Key features of MILESEEY TR10 including 192x192 resolution, temperature range, sensitivity, and tracking.
Key Features Summary

Setup

What's in the Box

Upon unboxing your MILESEEY TR10, you should find the following items:

  • TR10 Thermal Camera
  • Quick User Guide
  • USB-C Cable
  • Hanging Strap
Contents of the MILESEEY TR10 box: thermal camera, user guide, USB-C cable, and hanging strap.
Contents of the Box

Device Layout and Controls

Familiarize yourself with the camera's components and controls:

  1. USB-C Charging Port: For charging and data transfer.
  2. LCD Screen: Displays thermal images and settings.
  3. Picture Memory Record: Indicates image storage status.
  4. Up/Down/Left/Right Buttons: Short press to navigate menus.
  5. Power On/Off/Return Button: Long press to power on or off; short press to return.
  6. Settings Button: Short press to enter setting options.
  7. Thermal Camera Lens: Captures infrared radiation.
  8. Picture Capturing Trigger: Short press to capture and save pictures.
Diagram showing the layout of the MILESEEY TR10 thermal camera with numbered components.
Device Layout
Close-up of the MILESEEY TR10 controls, showing navigation, set, power, and capture buttons.
Control Buttons

Operating Instructions

Display Icons

The LCD screen displays various information during operation:

  1. Battery Status
  2. Center Temperature
  3. Center Point/Cross-Hairs
  4. Max Temperature and Position
  5. Min Temperature and Position
  6. Time
  7. Max Temperature on the Bar
  8. Temperature Bar
  9. Min Temperature on the Bar
  10. N: Normal (Note: N shifts to H when High Temp Range is selected)
  11. Emissivity
  12. Detection Distance
Diagram explaining the icons and information displayed on the MILESEEY TR10 screen.
Display Icon Explanation

Settings Interface Navigation

To access and adjust settings:

  • Press the SET button to enter the settings menu.
  • Navigate to your desired option using the Up/Down buttons.
  • Press SET again to access the specific setting.
  • Adjust values or select sub-options using the Up/Down buttons.
  • Confirm and save changes by pressing the SET button.
  • To return to the main settings menu, briefly press the Return button.

Emissivity Setting

Correct emissivity is crucial for accurate temperature measurements. To set:

  1. Select 'Emissivity' from the settings menu and press SET.
  2. Adjust the value using the Up/Down buttons (range 0.01 to 0.99).
  3. Press SET to confirm.
  4. Refer to the table below for common material emissivity values.
Emissivity of Common Objects
Materials Emissivity Materials Emissivity
Wood0.85Black Paper0.86
Water0.96Polycarbonate0.8
Brick0.75Concrete0.97
Stainless Steel0.14Copper Oxide0.78
Adhesive Tape0.96Cast Iron0.81
Aluminium Plate0.09Rust0.8
Copper Plate0.96Gypsum0.75
Black Aluminum0.75Paint0.9
Human Skin0.98Rubber0.95
Asphalt0.96Soil0.93
PVC Plastic0.93

Distance Setting

For accurate temperature detection, set the distance to the target:

  1. Select 'Distance' from the settings menu and press SET.
  2. Adjust the distance value using the Up/Down buttons (range 0.3 to 3 meters).
  3. Press SET to confirm.

Temperature Range Setting

The TR10 offers two temperature ranges:

  • Normal: -20°C to 150°C (-4°F to 302°F)
  • High: 100°C to 550°C (212°F to 1022°F)

To set the temperature range:

  1. Select 'Temp Range' from the settings menu and press SET.
  2. Toggle between 'Normal' and 'High' using the Up/Down buttons.
  3. Press SET to confirm.

Note: Switching ranges takes approximately 10 seconds. Wait for the device to complete the switch before further operations.

Temperature Units Setting

To change temperature units:

  1. Select 'Temperature Units' from the settings menu and press SET.
  2. Toggle between °C and °F using the Up/Down buttons.
  3. Press SET to confirm.
  4. You can also set ambient temperature for enhanced accuracy with low emissivity materials.

Palette Setting

The TR10 offers 8 color palettes to visualize thermal data:

  • White Hot
  • Black Hot
  • Iron
  • Rainbow
  • Blend
  • Red Hot
  • Blue Hot
  • Green Hot

To set the color palette:

  1. Select 'Palette' from the settings menu and press SET.
  2. Toggle through the palettes using the Up/Down buttons.
  3. Press SET to confirm.
Examples of different color palettes: White Hot, Black Hot, Iron, Rainbow, Blend, Red Hot, Blue Hot, Green Hot.
Available Color Palettes

HI/LO Alarm Setting

Set high and low temperature alarms to be alerted to critical conditions:

  1. Select 'HI/LO Alarm' from the settings menu and press SET.
  2. Toggle the alarm on/off using the Up/Down buttons.
  3. Adjust the high and low temperature thresholds using the Up/Down buttons.
  4. Press SET to confirm.
Diagram showing high and low temperature alarm settings on the MILESEEY TR10.
High/Low Temperature Alarm Interface

Display Options

Customize the on-screen display elements:

  1. Select 'Display' from the settings menu and press SET.
  2. Scroll through options like High/Low Temp Dot, Center Dot, Palette (color bar), and parameter (emissivity and distance) using the Up/Down buttons.
  3. Press SET to toggle elements on or off.

Brightness Setting

Adjust the screen brightness for optimal viewing:

  1. Select 'Display Brightness' from the settings menu and press SET.
  2. Toggle between Low, Mid, and High options using the Up/Down buttons.
  3. Press SET to confirm.

Date & Time Setting

Set the correct date and time:

  1. Select 'Date & Time' from the settings menu and press SET.
  2. Toggle between 12H and 24H formats using the Up/Down buttons.
  3. Navigate to the desired field (Year, Month, Day, Hour, Minute) using Left/Right buttons.
  4. Adjust values using the Up/Down buttons.
  5. Press SET to confirm.

Image Capture and Browsing

To capture thermal images, short press the Picture Capturing trigger (button 8 on the device layout). Images are automatically saved to the 8GB internal memory.

To browse captured images:

  1. Short press the Picture Memory Record button (button 3 on the device layout) to enter the photo album.
  2. Use the Up/Down buttons to scroll through different pictures.
  3. Press SET to open a specific picture.
MILESEEY TR10 Thermal Camera side view with trigger button highlighted.
Picture Capturing Trigger

Maintenance

Cleaning the Device

As mentioned in the safety instructions, gently wipe the exterior with a damp cloth or a mild soap solution. Avoid harsh chemicals.

Correction (Image Clarity)

If image clarity is compromised due to sensor noise after prolonged use, perform a correction:

  1. Select 'Correction' from the settings menu and press SET.
  2. The device will process the correction to eliminate noise and restore optimal thermal image clarity.

USB Mode (Data Transfer)

To transfer images to a PC:

  1. Select 'USB Mode' from the settings menu and press SET.
  2. Toggle between 'USB Disk' and 'USB Camera' using the Up/Down buttons. Select 'USB Disk'.
  3. Press SET to confirm.
  4. Restart the thermal imager and connect it to your computer using the USB-C cable.
  5. The device will appear as a removable disk, allowing you to browse and transfer images.

Note: Do not rename the 'Image' folder or image files to prevent reading errors.

Format Disk

To erase all data on the internal storage:

  1. Select 'Format Disk' from the settings menu and press SET.
  2. Toggle between 'Yes' and 'No' using the Up/Down buttons.
  3. Press SET to confirm.

Caution: Confirming this action will permanently erase all data on the disk.

Factory Reset

To restore the device to its original factory settings:

  1. Select 'Factory Reset' from the settings menu and press SET.
  2. Toggle between 'Yes' and 'No' using the Up/Down buttons.
  3. Press SET to confirm.

Caution: Confirming this action will permanently erase all data and settings on the device.

Troubleshooting

If you encounter issues with your MILESEEY TR10, consider the following:

  • Inaccurate Readings:
    • Check and adjust the emissivity setting for the target material.
    • Ensure the device has warmed up for at least 2 minutes if it hasn't been used recently.
    • Avoid taking measurements while the device is charging.
    • Verify the detection distance is set correctly.
  • Image Clarity Issues:
    • Perform a 'Correction' from the settings menu to eliminate sensor noise.
  • Device Not Connecting to PC:
    • Ensure 'USB Mode' is set to 'USB Disk' in the settings.
    • Restart the thermal imager after changing the USB mode.
    • Check the USB-C cable for damage and ensure it's properly connected.
    • Do not rename the 'Image' folder or image files on the device.
  • Device Not Powering On:
    • Ensure the battery is charged. Connect the device to a power source using the USB-C cable.
    • Perform a long press on the Power button.
  • Settings Not Saving:
    • Ensure you press the SET button to confirm changes after adjusting a setting.

Specifications

Feature Specification
ModelTR10
NETD< 50mK
Super-Resolution192x192
Minimum Imaging Distance0.3m
HFOV (Horizontal Field of View)50°x50°
IFOV (Instantaneous Field of View)8.89 mrad
Frame Rate25 Hz
Focal Length1.35mm
Gross Storage Capacity8GB
Usable Storage Capacity6GB
Output PortType-C
Battery3.7V, 3200mAh Rechargeable Lithium
Temperature Measuring Range-20°C to 550°C (-4°F to 1022°F)
Accuracy±2°C/±2%
Picture Storage Capacity30,000
Picture FormatJPEG
Screen2.8" LCD Display
Max Picture Size240 x 240
Color PalettesWhite Hot, Black Hot, Iron, Rainbow, Blend, Red Hot, Blue Hot, Green Hot
Dimensions224*76*91mm
Net Weight345g

User Tips

  • Great Value: Many users find the TR10 offers excellent value and quality for its price point.
  • Versatile Applications: The camera is highly effective for structural analysis, identifying hydraulic leaks, and diagnosing electrical problems.
  • Well-Built: Users appreciate the robust construction and comfortable feel of the device.
  • High Sensitivity: The TR10's sensitivity allows it to detect heated objects even through walls, making it useful for hidden issues.
  • Learning Curve: While user-friendly, some users note that it may take a little time to get fully accustomed to all its features.
  • Heating Component Search: Works well for locating and analyzing heating components.

Warranty & Support

Warranty Terms

This product comes with a one-year guarantee against non-artificial damage. Certain maintenance costs may be charged under the following circumstances:

  • Damages caused by improper usage or maintenance.
  • The machine has been disassembled or mended by unauthorized third parties.
  • Absence of a warranty card or purchase invoice.
  • The serial number on the warranty card differs from that on the product.
  • The serial number has been altered or abraded.
  • Damage due to force majeure factors.
  • Replacement of worn-out accessories.
  • Damages caused by abnormal factors such as extreme temperature/humidity during usage.
  • Damages caused by improper operation.

Please send the machine with the warranty card and purchase invoice to your local dealer if maintenance is needed. The warranty card will not be reissued if lost; please keep it carefully for maintenance.

Contact Information

Manufacturer: Shenzhen Mileseey Technology Co., Ltd.

Address: No.3601 Block A, Tanglang Town Plaza West, Fuguang Community, Taoyuan Street, Nanshan District, Shenzhen, China

Website: www.mileseey.net

Store: www.mileseeytools.com

E-mail: service@mileseey.com

Made in: China

For the full user manual in PDF format, please refer to the official documentation available at MILESEEY TR10 User Manual (PDF).

Product Video

Play video
Watch video online
Unboxing and demonstration of the MILESEEY TR10 Thermal Camera, showcasing its features and ease of use.
Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.