HoldPeak HP-5000G

Contents

HP-5000G Anemometer User Manual

Model: HP-5000G | Brand: HoldPeak

1. Introduction

The HoldPeak HP-5000G Anemometer is a compact, waterproof digital instrument designed for accurate measurement of wind speed, air volume, and temperature. Equipped with anti-interference touch buttons, a clear LCD display, and a rechargeable Type-C battery, it is suitable for a wide range of applications including navigation, shooting, drone test flights, mountain climbing, outdoor sports, and HVAC system checks.

Video: Product demonstration, including battery installation, wind tunnel testing, and outdoor usage scenarios.

HP-5000G Anemometer with labeled buttons for wind speed, air volume, unit switch, power, data hold, and backlight.

Figure 1: HP-5000G Anemometer with labeled controls and display showing 360° wind speed measurement capabilities.

HP-5000G Anemometer displaying various measurement modes including unit switching, temperature, auto-off, data hold, MAX/MIN/average, wind chill, wind scale, and backlight.

Figure 2: Multifunctional measurement capabilities of the HP-5000G Anemometer.

2. Package Contents

Please check the package contents upon receipt to ensure all items are present:

  • 1x HP-5000G Anemometer
  • 1x Type-C Charging Cable
  • 1x Operation Manual
  • 1x Screwdriver
  • 1x Hand Strap
  • 1x Packing Box
Image showing the HP-5000G Anemometer, packing box, screwdriver, hand strap, and manual as package contents.

Figure 3: Contents included in the HP-5000G Anemometer package.

3. Setup

3.1 Battery Installation

Before initial use, the internal rechargeable lithium battery needs to be connected. Follow these steps:

  1. Use the small screwdriver provided to unscrew the screws on the battery cover located at the back of the device.
  2. Carefully remove the battery cover.
  3. Connect the battery line, ensuring correct polarity (connect wires of the same color together).
  4. Place the battery inside the compartment.
  5. Close the battery cover and secure it with the screws.
Diagram showing the steps to unscrew the battery cover, connect the battery, and close the cover.

Figure 4: Battery installation steps for the HP-5000G Anemometer.

3.2 Charging

The HP-5000G uses a Type-C interface for charging. Connect the provided Type-C charging cable to the device and a suitable power source. The battery capacity is 400mAh and takes 2 to 3 hours to fully charge. A low battery icon will be displayed on the LCD when the battery is low.

3.3 Tripod Mounting

The anemometer is equipped with a metal tripod screw hole on the bottom, allowing it to be mounted on a tripod for continuous wind measurement and hands-free operation.

HP-5000G Anemometer mounted on a tripod, showing the hand strap and a compass on top.

Figure 5: Anemometer mounted on a tripod, highlighting the tripod screw hole, hand strap, and integrated compass.

4. Operating Instructions

The HP-5000G Anemometer features anti-interference touch buttons for easy operation. Refer to the diagram below for button identification and functions.

Diagram of the anemometer's control panel with numbered buttons and their corresponding functions: Power On/Off, Wind Speed/Air Volume Function Switch, MAX/MIN/Real-time Value Switch, Wind Speed/Air Volume Unit Switch, Set Air Volume Area/Temperature Unit Switch, Data Hold/Backlight Switch.

Figure 6: Control panel and button functions.

  1. Power On/Off (Button ①): Press and hold for 1 second to turn on the device. The screen will fully display upon startup. Briefly press to turn off.
  2. Automatic Power-Off Mode (Button ①): In the power-off state, press and hold Button ① for 5 seconds. The LCD will show "ON" (automatic power-off enabled) or "OFF" (automatic power-off disabled). Release the button, then briefly press Button ① to toggle between ON/OFF. After selecting, briefly press Button ① to enter the power-on state. In automatic power-off mode, the "" symbol indicates a 5-minute auto-off timer.
  3. Wind Speed/Air Volume Function Switch (Button ②): Briefly press Button ② to switch between wind speed and air volume measurement functions.
  4. Wind Speed Maximum/Minimum/Real-time Value Switch (Button ③): Briefly press Button ③ to cycle through maximum value (MAX), minimum value (MIN), and real-time value (Actual) for wind speed and air volume.
  5. Wind Speed/Air Volume Unit Switch (Button ④):
    • Wind Speed Mode: Briefly press Button ④ to switch between units: m/s, km/h, ft/min, knots, and MPH.
    • Air Volume Mode: Briefly press Button ④ to switch between units: CFM, CMS, CMM.
    • Secondary Display Area Units: In air volume mode, press and hold Button ④ to switch between square meters (m²) and square feet (ft²) for the secondary display area.
  6. Set Air Volume Area Key & Temperature Unit Switch (Button ⑤):
    • Wind Speed Mode: Briefly press Button ⑤ to toggle between secondary display temperature units: Celsius (℃) and Fahrenheit (℉).
    • Air Volume Mode: Briefly press Button ⑤ to set the area value. The "AREA" symbol will flash. Press the "UNIT" button to select the desired digit position (hundreds, tens, units, decimal). Press the "MAX/MIN" button to adjust the numeric value (0~9). After adjusting, press Button ⑤ again to confirm and exit the area setting.
  7. Data Hold and Backlight Switch (Button ⑥): Briefly press Button ⑥ to activate the data hold function for current measurements. Press and hold Button ⑥ for more than 3 seconds to activate or deactivate the backlight.
Detailed diagram of the HP-5000G Anemometer with labels for Wind Chill Sensor, Type-C Port, Battery Cover, LCD Screen, Power On/Off Button, Wind Speed/Air Volume Function Switch Button, Wind Speed Maximum/Minimum/Real-time Value Switch Button, Wind Speed/Air Volume Unit Switch Button, Air Volume Area Button & Temperature Unit Switch Button, Data Hold & Backlight Button, and Tripod Screw Hole. Dimensions are also shown.

Figure 7: Labeled parts and dimensions of the HP-5000G Anemometer.

5. Specifications

ParameterRangeResolutionAccuracy
Wind Speed Measurement
m/s0.3 ~ 300.1±5%
ft/min59 ~ 590519
Knots (kt)1 ~ 550.2
km/h2 ~ 900.3
MPH1 ~ 650.2
Temperature Measurement
°C-10°C ~ 45°C0.2±2°C
°F14°F ~ 113°F0.36±3.6°F
Air Volume Measurement
CMM (M³/MIN)0 ~ 9999000.001 ~ 1000.001 ~ 9999 (Area)
CMS (M³/S)0 ~ 9999000.001 ~ 1000.001 ~ 9999 (Area)
CFM (FT³/MIN)0 ~ 9999000.001 ~ 1000.001 ~ 9999 (Area)
General Specifications
BatteryLithium Battery Model: 60204 (400mAh). Takes 2 to 3 hours to fully charge.
Operating Temperature-10°C ~ 45°C (14°F ~ 113°F)
Relative Humidity≤90%RH
Storage Temperature-20°C ~ 50°C (-4°F ~ 122°F)
Current ConsumptionApproximately 3mA
Dimensions203*87.3*87.3mm
WeightApproximately 180g (including battery)

Note: The product images and content are for reference only. Please refer to the actual product for any discrepancies or updates. The manufacturer reserves the right to make changes without prior notice.

HP-5000G Anemometer measuring air flow in an HVAC system, with a table showing CMM, CMS, and CFM units, ranges, resolutions, and area settings.

Figure 8: Anemometer used for HVAC air flow measurement, detailing air volume specifications.

6. Maintenance

  • Cleaning: Use a soft, damp cloth to clean the device. Do not use abrasive cleaners or solvents.
  • Storage: When not in use for extended periods, store the anemometer in a dry, cool place away from direct sunlight.
  • Battery Care: Ensure the battery is charged periodically if stored for a long time to maintain its lifespan.

7. Troubleshooting

  • Device not turning on: Ensure the battery is correctly connected and fully charged.
  • Low Battery Indication: If the low battery icon appears on the LCD, recharge the device using the Type-C charging cable.
  • Inaccurate Readings: Ensure the wind cups are free from obstructions and rotate smoothly. For air volume measurements, ensure the correct area value is set.

8. User Tips

  • The anemometer is designed for ease of use and provides stable, accurate readings.
  • Its compact and waterproof design makes it highly suitable for various outdoor activities and challenging weather conditions.
  • Remember to connect the battery after unscrewing the cover before the first use.

9. Warranty and Support

The HP-5000G Anemometer comes with a one-year warranty. For any problems or concerns, professional technical support is available. To ensure a prompt response and quick processing of your requests, please email the support team with the following information:

  • Order Number
  • Platform of Your Purchase
  • Full Model Number (HP-5000G)
  • Description of the Problem (Attaching videos or photos can help troubleshoot faster)

Support Email: AFTERSALES1010@HOTMAIL.COM

You can also refer to the official user manual PDF for more detailed information: View User Manual (PDF)

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.