CERTEON TD-32A/TD-55A/TD-32/TD-55

Contents

Digital Sugar Refractometer User Manual

Model: TD-32A / TD-55A / TD-32 / TD-55

Brand: CERTEON

1. Product Description

The Handheld Digital Brix Meter is a portable optical measuring instrument designed to determine the sugar concentration of liquids such as fruit juice, beverages, and other food products. The device measures Brix value, temperature, and refractive index using an integrated optical prism and digital sensor system. Automatic Temperature Compensation ensures reliable readings under varying environmental conditions. The compact battery-powered design makes the instrument suitable for field testing, laboratories, agriculture, food processing, and quality control applications.

Digital Refractometer Display showing temperature, Brix, and Refractive Index
Close-up of the refractometer display showing current temperature, Brix value, and refractive index.

2. Product Components

Diagram of refractometer components including light shield, optical prism, chamber, display, and buttons
Diagram of refractometer components: Light Shield, Optical Prism, Chamber, Temperature, Measured Value, Battery Level, Refractive Index, Hold to Reset (1s to clear), Power On/Off (Press 1s), Measure Button.

3. Package Contents

The product package typically includes the following items:

  • Digital Brix Meter (Refractometer)
  • User Manual
  • 2 x AA Batteries
  • Screwdriver
  • Cleaning Cloth
Contents of the product package including the refractometer, batteries, screwdriver, and cleaning cloth
Illustration of typical package contents.

4. Specifications

Parameter Value
Model TD-32A / TD-55A / TD-32 / TD-55
Measuring Range 0-32% Brix (TD-32/TD-32A) or 0-55% Brix (TD-55/TD-55A)
Measured Items Brix value, Temperature, Refractive Index (TD-32A/TD-55A models only)
Temperature Compensation Automatic Temperature Compensation (ATC)
Display HD Backlit Digital Display
Optical System High-transmission optical prism with anti-scratch coating
Power Supply 2 × AA Batteries
Application Media Fruit juice, beverages, soft drinks, and other sugar-containing liquids
Common Fruit Brix Reference Table
Common Fruit Brix Reference Table (Data for reference only).

5. Setup

5.1 Battery Installation

  1. Open the battery compartment cover.
  2. Insert two AA batteries, ensuring correct polarity (+/-) as marked inside the compartment.
  3. Close the battery compartment cover securely.

5.2 Initial Preparation

  • Ensure the prism surface is clean before measurement. If necessary, gently wipe the prism using a soft lint-free cloth.

6. Operation

6.1 Measurement Steps

  1. Power On: Press the power button (usually marked with a power symbol) to start the device.
  2. Apply Sample: Place a small sample of the liquid to be tested onto the optical prism in the measurement groove. Ensure the liquid fully covers at least two-thirds of the prism surface.
  3. Measure: Press the measurement button (usually marked 'MEAS') to initiate the test.
  4. Read Data: The instrument will automatically analyze the sample and display the Brix value, temperature, and refractive index (if applicable to your model) on the backlit display.
  5. Clean: After measurement, clean the prism with distilled water and wipe it dry using a soft cloth before proceeding to the next measurement.
Visual guide for measurement steps: Power on, Add sample, Measure, Clean
Step-by-step visual guide for using the refractometer.

7. Precautions

  • This instrument is a precision optical device. Avoid drops or strong impacts.
  • Do not scratch the optical prism in the groove with hard or sharp objects.
  • Ensure the prism is clean before each measurement to prevent inaccurate readings.
  • Do not immerse the instrument in water or other liquids. The instrument is NOT waterproof.
  • Store the instrument in a dry environment when not in use.
  • Remove the batteries if the device will not be used for a long period to prevent leakage damage.
  • Operate the device within normal environmental temperature and humidity conditions.
  • USB charging voltage must not exceed DC 6V (if applicable to your model).

8. Maintenance and Storage

  • Clean the prism after each measurement using distilled water and a soft cloth.
  • Avoid using abrasive materials or chemical solvents on the optical surface.
  • Store the instrument in a dry and dust-free location.
  • For long-term storage, remove the batteries to prevent leakage damage.
  • Regularly check the prism surface and battery contacts to maintain measurement reliability.

9. Troubleshooting

  • Inaccurate Readings: Ensure the optical prism is perfectly clean, the sample fully covers the prism surface, and the device has been zeroed correctly. Verify that the sample temperature is within the operating range for accurate Automatic Temperature Compensation (ATC).
  • Device Not Turning On: Check if the AA batteries are installed correctly with the right polarity. Replace batteries if they are depleted.
  • Display Issues: If the display is dim or unreadable, check battery level and replace if necessary. Ensure the device is not exposed to extreme temperatures.

10. User Tips

  • For quick and accurate sugar content checks, always ensure the prism is clean and the liquid sample completely covers the sample well.
  • When measuring pulpy juices (e.g., citrus), filter out any solid particles or pulp before applying the sample to the prism for the best accuracy.

11. Warranty and Support

For technical assistance, warranty inquiries, or any questions regarding your CERTEON Digital Sugar Refractometer, please contact the seller directly:

  • WhatsApp: +86-19542723588
  • Email: celiachen008@gmail.com

Please refer to the official seller's website or contact information for the most up-to-date support details.

12. Compliance and Warning Information (EU Market Reference)

General Warnings:

  • Do not disassemble or modify the device. Unauthorized modifications may affect measurement accuracy and safety.
  • Do not expose the instrument to extreme temperatures, strong vibration, or corrosive substances.
  • Batteries must be installed correctly and replaced with the same type to prevent leakage or damage.
  • Keep out of reach of children.
  • Proper disposal is required. Electronic products and batteries must be disposed of according to the WEEE Directive and local environmental regulations.

Note: The above warning information is for reference only. Final warning language must comply with the official language requirements of the destination EU country.

Compliance Disclaimer:

This document is provided for product instruction purposes only. It does not constitute legal advice. The seller is responsible for ensuring compliance with destination market regulations.

For a comprehensive user manual, please refer to the official PDF document: User Manual (PDF)

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.