CERTEON TA60 Series

Contents

CERTEON TA60 Series Handheld Infrared Thermometer

User Manual

1. Product Description

The TA60 Series Handheld Infrared Thermometer is a non-contact temperature measuring instrument designed for industrial and commercial applications. It utilizes infrared sensing technology with laser targeting to measure surface temperature quickly and safely without physical contact.

The device is suitable for monitoring temperature of oil, water, food processing surfaces, HVAC systems, metal processing equipment, ovens, and cold storage facilities. Selected models support K-type thermocouple input and ambient environmental measurements.

This series offers a wide temperature range, adjustable emissivity, 9-point laser targeting, a VA color display, and high/low temperature alarms. The TA602D model also includes voice broadcast, ambient temperature, dew point, and wet bulb readings for comprehensive monitoring.

Handheld Infrared Thermometer TA60 series with key specifications
Overview of the CERTEON TA60 Series Infrared Thermometer, highlighting its features and specifications.

2. Setup

2.1. Package Contents

Product packaging and contents including thermometer, pouch, manual, and batteries
The product package typically includes the infrared thermometer, a fabric pouch, a lanyard, a user manual, a certificate of conformity, and 2x AAA batteries (batteries not included unless specified by seller).

2.2. Battery Installation

  1. Locate the battery compartment on the handle of the thermometer.
  2. Open the battery cover.
  3. Install two AAA batteries according to the polarity markings inside the compartment.
  4. Ensure the battery cover is securely closed.
Battery compartment of the infrared thermometer showing AAA batteries installed
The battery compartment is designed for two AAA batteries, ensuring long-lasting performance.

2.3. Initial Settings

  • Temperature Unit: Select the desired temperature unit (°C or °F) using the appropriate button on the device.
  • Emissivity: Adjust the emissivity setting according to the surface material being measured for more accurate readings. The default emissivity is 0.95, and it is adjustable from 0.10 to 1.00 in 0.01 steps.
Diagram showing adjustable emissivity feature and controls
Adjusting emissivity for different object surfaces is crucial for accurate temperature measurements.

3. Operating Instructions

3.1. Basic Measurement

  1. Hold the thermometer by the handle and point the laser toward the target surface.
  2. Maintain an appropriate measuring distance according to the 12:1 distance-to-spot ratio.
  3. Press and hold the trigger to initiate measurement.
  4. Read the measured value directly from the VA color display.
  5. Release the trigger to hold the displayed value. The device will automatically power off after a period of inactivity.
Infrared thermometer performing a fast temperature measurement on an air conditioner
One-click instant measurement provides fast and efficient temperature readings without contact.

3.2. Distance-to-Spot Ratio (D:S)

The D:S ratio for this thermometer is 12:1. This means that as the distance between the thermometer and the target increases, the measurement area also enlarges accordingly. Ensure the target surface is larger than the calculated spot size to avoid measurement errors.

Diagram illustrating the 12:1 Distance-to-Spot Ratio
Understanding the 12:1 D:S ratio is essential for accurate targeting and measurement.

3.3. Laser Targeting

When the device is powered on, gently press the "triangle" button to turn the laser on/off. The 9-point laser positioning helps to quickly and precisely lock onto the measurement area.

Infrared thermometer using 9-point laser positioning for quick target locking
9-Point Laser Positioning ensures quick and accurate target locking within the measurement range.

3.4. K-Type Thermocouple Measurement (TA602D only)

For the TA602D model, connect a compatible K-type probe if contact measurement is required. This allows for a wider range of temperature measurements, typically -50°C to 300°C.

Infrared thermometer with K-Type Thermocouple in use
The K-Type Thermocouple extends the measurement capabilities for specific applications.

3.5. Screen Display Overview (TA602D)

Screen display overview for TA602D model showing various indicators
The TA602D model's VA color display provides a comprehensive overview including adjustable emissivity, ambient humidity, MAX/MIN/AVG values, K-Type temperature, dew point, wet bulb temperature, data hold, and non-contact temperature readings.

3.6. Special Measurement Notes

When measuring boiling liquids, avoid smoke or steam contacting the sensor's temperature detection area. Maintain a measuring angle of approximately 45° to 60°. For reflective surfaces like stainless steel, it's recommended to apply black tape to the surface or open the lid to measure the temperature of the boiling water inside.

Diagram showing correct and incorrect methods for water/oil temperature measurement
Proper technique for measuring water/oil temperature to ensure accuracy.

3.7. Product Overview Video

Watch this video for an overview of the industrial automation processes related to CERTEON products.

4. Maintenance

4.1. Storage

  • Store the instrument in a dry and clean environment within the specified storage temperature range (-20°C to 60°C).
  • Remove batteries if the instrument will not be used for an extended period to prevent leakage.

4.2. Cleaning

  • Clean the lens gently with a soft cloth.
  • Do not use solvents or abrasive cleaners.

4.3. General Care

  • Regularly inspect the battery compartment for corrosion or leakage. Replace batteries when the low battery indicator appears.
  • Avoid dropping or subjecting the device to mechanical shock. The ABS material provides durability, but excessive force can cause damage.
Infrared thermometer made of ABS material, highlighting its drop-resistant and dustproof features
The robust ABS material ensures the thermometer is durable, drop-resistant, and dustproof for safe and worry-free use.

5. Troubleshooting

  • "LO" or "HI" Indication: If the measured value exceeds the selected temperature range, "LO" (low) or "HI" (high) will be displayed on the screen. Ensure the target temperature is within the device's specified range.
  • Low Battery Indicator: If the low battery indicator appears, replace the AAA batteries promptly to ensure accurate readings and proper device function.
  • Inaccurate Readings: Ensure emissivity is correctly set for the material being measured. Verify the distance-to-spot ratio is maintained. Avoid strong electromagnetic fields or sudden temperature changes that could cause condensation.
  • Device Not Responding: Check battery installation and charge. If the issue persists, remove and reinsert batteries.

6. Specifications

6.1. General Specifications

  • Power Supply: 2 x 1.5 V AAA batteries
  • Rated Voltage: 3 V DC
  • Size: 155 × 92 × 42 mm
  • Net Weight: Approx. 180 g (without batteries)
  • Display Type: VA color screen with backlight
  • Operating Temperature: 0°C to 50°C
  • Operating Humidity: 10% to 95% RH non-condensing
  • Storage Temperature: -20°C to 60°C
  • Response Time: <500 ms
  • Spectral Response: 8–14 μm
  • Distance to Spot Ratio: 12:1
  • Laser Class: Class II, <1 mW, 650 nm
  • Auto Power Off: Supported

6.2. Model-Specific Specifications

TA601 and TA602 Series Specifications
Parameter TA601A TA601B TA601C TA602D
Temperature Range -50℃~480℃ (-58℉~896℉) -50℃~680℃ (-58℉~1256℉) -50℃~880℃ (-58℉~1616℉) -50℃~880℃ (-58℉~1616℉)
Accuracy ±(1.5% of reading ±1℃)
Repeatability ±0.5% of reading or ±1℃ (2℉)
Resolution 0.1℃ / 0.1℉
Emissivity 0.1–1.0 adjustable (0.01 step)
Unit Switch (°C/°F) Yes Yes Yes Yes
Backlight Display Yes Yes Yes Yes
K-type Probe Temp. No No No -50℃~300℃
Ambient Temp. & Humidity Display No No No Yes
Dew Point Temp No No No -50~60℃
Wet Bulb Temp No No No -20~60℃
Voice Broadcast No No No Yes
Overrange Alert “LO” or “HI”
Product Specifications table for TA601A, TA601B, TA601C, TA602D
Detailed specifications for TA601 and TA602 series models.
TA603 Series Specifications
Parameter TA603A TA603B TA603C TA603D TA603E
Temperature Range -32~1080℃ (-26~1976℉) -32~1380℃ (-26~2516℉) -32~1680℃ (-26~3056℉) -32~1880℃ (-26~3416℉) -32~2200℃ (-26~3992℉)
Accuracy -32~100℃ (±2℃), -26~212℉ (±4℉)
100~800℃ (±2%), 212~1472℉ (±2%)
Above 800℃ (±3%), Above 1472℉ (±3%)
Repeat Accuracy ±1% or ±1℃ (2℉)
Display Resolution -32~100℃ (±2℃) -26~212℉ (±4℉)
Response Time & Wavelength <500ms 8–14μm
Emissivity Adjustable 0.1–1.00 (Step 0.01)
Distance to Spot Ratio 50:1 80:1
Laser Targeting <1mW 650nm, Laser Class II
°C/°F Switch √
Screen Type VA Color Display
Backlight Display √
Overrange Alert “HI” or “LO”
Data Storage 255 sets
Power Supply 9V 6F22
Operating Temp. / Humidity 0℃~50℃ / 10~85%RH Non-condensing
Storage Temp. -20℃~60℃ (excluding battery)
Product Dimensions 213 × 140 × 60mm
Net Weight Approx. 180g
Product Specifications table for TA603A, TA603B, TA603C, TA603D, TA603E
Detailed specifications for TA603 series models.

6.3. Emissivity Table for Common Materials

Material Emissivity Material Emissivity
Aluminum0.3Iron0.7
Rock Wool0.95Zinc0.5
Limestone0.95Marble0.98
Basalt0.7Oil0.94
Brass0.5Paint0.93
Brick0.9Paper0.95
Carbon0.85Plastic0.95
Ceramic0.95Rubber0.95
Concrete0.95Sand0.9
Copper0.95Leather0.75
Oil Sludge0.94Snow0.98
Frozen Food0.9Steel0.8
Hot Food0.93Fabric0.94
Glass (Flat)0.85Water0.93
Ice0.98Wood0.94
Table of emissivity values for various materials
Reference table for adjusting emissivity based on material type.

7. User Tips

  • Industrial Use: This thermometer is excellent for equipment inspection, providing fast and accurate temperature readings without direct contact, which is ideal for industrial environments.
  • Reflective Surfaces: When measuring highly reflective surfaces like polished metals, consider applying a piece of black tape to the surface and measuring the temperature of the tape, or measure through an opening to get a more accurate reading.
  • TA602D Advanced Features: If you have the TA602D model, utilize its voice broadcast, ambient temperature, dew point, and wet bulb measurement capabilities for more comprehensive environmental monitoring.
  • Optimal Measurement Angle: For liquids, maintain a measuring angle of approximately 45° to 60° to avoid interference from steam or smoke.

8. Safety Warnings

8.1. Laser Safety

WARNING!

  • This product contains a Class II laser.
  • Do not look directly into the laser beam or point it at eyes or reflective surfaces.

8.2. Environmental and Usage Restrictions

  • Do not use the instrument in explosive atmospheres or near flammable gases.
  • Do not expose the device to strong electromagnetic fields or extreme humidity.
  • Avoid sudden temperature changes which may cause condensation inside the device.

8.3. Medical Use Disclaimer

This device is not a medical instrument and must not be used for measuring human body temperature.

8.4. Child Safety

Keep out of reach of children.

8.5. Product Disposal

Dispose of this product in accordance with the Waste Electrical and Electronic Equipment Directive WEEE 2012/19/EU. Do not dispose of with household waste.

Note: The above warning information is for reference only. Final warning language must comply with the official language requirements of the destination EU country.

9. Compliance Disclaimer

This document is provided for product instruction purposes only. It does not constitute legal advice.

The seller is responsible for ensuring compliance with destination market regulations including CE marking, RoHS compliance, and applicable low voltage and electromagnetic compatibility directives.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.