SUSWE SU650

Contents

SUSWE SU650 Series Vector Frequency Converter

User Instruction Manual

Model: SU650 Series (0.75KW - 5.5KW)

Brand: SUSWE

1. Introduction

The SUSWE SU650 series Vector Frequency Converter is a high-performance device designed for precise speed and torque control of industrial motors. This converter is suitable for a wide range of industrial applications, providing efficient drive and robust protection for your machinery. It features a three-phase 380V input and output, with various power options to meet diverse operational requirements.

SUSWE VFD connected to a 3-phase motor
Figure 1: SUSWE VFD connected to a three-phase motor, demonstrating 3-phase input and output connections.

2. Safety Information

WARNING: Electrical shock hazard. Only qualified personnel should perform installation and maintenance.

  • Ensure the power supply is disconnected before any wiring or maintenance.
  • Verify correct voltage and phase connections (Three-phase 380V input).
  • Do not connect AC power to the output terminals (U, V, W) of the VFD.
  • Allow at least 5 seconds for the VFD to discharge after power-off before touching any components.
  • Ensure proper grounding of the VFD and motor.
  • Install the VFD in a well-ventilated area, free from dust, moisture, and corrosive gases.

3. Product Overview

The SU650 series VFD features a compact design with a user-friendly interface, including a detachable control panel for flexible installation.

Front, side, and rear views of the SUSWE VFD
Figure 2: Multiple views of the SUSWE VFD unit.
Detachable control panel of SUSWE VFD
Figure 3: The detachable control panel allows for flexible installation and easy operation.

Control Panel Components:

SUSWE VFD control panel with labeled buttons and display
Figure 4: Front view of the VFD with control panel details.
  1. Display: Digital readout for frequency, voltage, current, and parameter settings.
  2. Rotary Knob: Used for adjusting frequency or parameter values.
  3. RUN Button: Starts motor operation.
  4. L/R (Forward/Reverse) Button: Changes motor rotation direction.
  5. PRG (Program) Button: Enters/exits parameter programming mode.
  6. UP Arrow Button: Increases parameter values or navigates menus.
  7. DOWN Arrow Button: Decreases parameter values or navigates menus.
  8. ENT/M.FK (Enter/Multi-function Key) Button: Confirms selections or performs multi-function tasks.
  9. RUN/STOP Button: Stops motor operation.

4. Specifications

The SUSWE SU650 series offers various power ratings. Please refer to the specific model for detailed parameters.

Detailed specifications and dimensions for 0.75KW SUSWE VFD model SU650-0R75-G3
Figure 5: Example specifications for the 0.75KW model (SU650-0R75-G3).
General Specifications (SU650 Series)
Parameter Value
Input Voltage Three-phase 380V
Output Voltage Three-phase 380V
Output Frequency 0-400Hz
Output Current 2.1A - 13A (depending on model)
Power Range 0.75KW, 1.5KW, 2.2KW, 4KW, 5.5KW
Output Type Triple
Weight 656g - 1057g (depending on model)
Certifications CE, FCC, RoHS

For a comprehensive list of compliant materials and test results, please refer to the official test report PDF: User manual (PDF).

CE and RoHS Certificates of Conformity for SUSWE VFD
Figure 6: CE and RoHS Certifications.

5. Installation and Setup

5.1 Mounting

  • Mount the VFD vertically on a flat, stable surface.
  • Ensure adequate clearance around the unit for proper ventilation, especially for the cooling fan.
  • The detachable panel allows for remote mounting of the control interface if needed.
Multiple SUSWE VFD units installed in an electrical control cabinet
Figure 7: Example installation of VFDs within an electrical control cabinet.

5.2 Wiring

All wiring must be performed by a qualified electrician. Ensure power is OFF before wiring.

  1. Power Input (AC POWER): Connect your three-phase 380V power supply to the input terminals (R, S, T). It is crucial to use a three-phase supply as specified.
  2. Motor Output (MOTOR): Connect the three-phase motor to the output terminals (U, V, W).
  3. Grounding: Connect the ground terminal of the VFD to a reliable earth ground.
  4. Control Wiring (Optional): For external control signals (e.g., start/stop, speed reference), refer to the detailed wiring diagrams in the full user manual PDF.
Wiring diagram showing 3-phase input and output connections for SUSWE VFD
Figure 8: Basic wiring connections for the VFD and motor.

Important Note: The VFD requires a three-phase 380V input. Using a single-phase input will result in improper operation or damage.

5.3 Initial Power-Up

  1. After completing all wiring, double-check all connections for security and correctness.
  2. Apply power to the VFD. The display should light up.
  3. The VFD may require initial parameter configuration depending on your motor and application. Refer to the programming section in the full user manual for details.

6. Operation

The VFD allows for precise control over motor speed and direction.

Diagram illustrating efficient drive performance and stable speed regulation for industrial motors with SUSWE VFD
Figure 9: The VFD provides stable speed regulation for industrial motors.

6.1 Basic Control Panel Operation

  • Starting the Motor: Press the RUN button.
  • Stopping the Motor: Press the RUN/STOP button.
  • Adjusting Speed: Rotate the Rotary Knob to change the output frequency, thereby adjusting motor speed. Alternatively, use the UP and DOWN arrow buttons.
  • Changing Direction: Press the L/R button to toggle between forward and reverse rotation.
  • Parameter Programming: Press the PRG button to enter parameter setting mode. Use the arrow keys to navigate and the ENT/M.FK button to confirm.

6.2 Motor Protection Features

The VFD includes comprehensive motor protection:

  • Over-current protection
  • Over-voltage protection
  • Under-voltage protection
  • Over-temperature protection
  • Short-circuit protection
SUSWE VFD features including 380V 3-phase input, power range, full motor protection, and CE & RoHS compliance
Figure 10: Key features of the SUSWE VFD, including full motor protection.

7. Maintenance

Regular maintenance ensures optimal performance and extends the lifespan of your VFD.

  • Cleaning: Periodically clean the VFD's exterior and cooling fan to prevent dust accumulation, which can hinder heat dissipation. Use a soft, dry cloth.
  • Cooling Fan: The VFD is equipped with a strong cooling fan for efficient heat dissipation. Ensure the fan is free from obstructions and operating correctly.
Close-up view of the SUSWE VFD's strong cooling fan
Figure 11: The strong cooling fan ensures efficient heat dissipation and silent operation.
  • Terminal Inspection: Regularly check all wiring terminals for tightness and signs of corrosion.
  • Environmental Check: Ensure the operating environment remains within specified temperature and humidity ranges.

8. Troubleshooting

This section provides solutions for common issues. For complex problems, consult the full user manual or contact technical support.

Common Troubleshooting Guide
Problem Possible Cause Solution
VFD does not power on No power supply; incorrect wiring; internal fault. Check power connections; verify input voltage; contact support if fault persists.
Motor does not run VFD not in RUN mode; motor wiring incorrect; parameter settings wrong; overload. Press RUN; check motor wiring (U,V,W); verify parameter settings (e.g., frequency reference); check for motor overload.
Motor speed is unstable Interference; incorrect PID settings; motor load fluctuations. Check for electromagnetic interference; adjust PID parameters; ensure stable motor load.
Over-current/Over-voltage fault Sudden load change; incorrect acceleration/deceleration time; power supply fluctuation. Adjust acceleration/deceleration times; check power supply stability; reduce load.

9. User Tips

  • Size Consideration: Users have noted the compact size of the VFD, making it suitable for installations where space is a concern, even for higher power ratings like 5.5KW.
  • Motor Speed Control: This frequency converter is effective for stepping down the RPM of electro motors, particularly 380V 50Hz motors, providing precise speed adjustments for various applications.
  • Input Power Verification: Always confirm that your power source is a true three-phase 380V supply. Misinterpreting wiring diagrams or using an incorrect power input (e.g., single-phase) can lead to damage.

10. Warranty and Support

For warranty information, technical support, or service inquiries, please refer to the contact details provided by your vendor or the official SUSWE website. Keep your purchase records for warranty claims.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.