1. Safety Information
This manual contains important safety instructions that must be followed during the operation of KUAIQU DC regulated power supplies. To ensure your personal safety and that this product works in the best environment, please read this manual carefully before using.
1.1. General Safety Brief
- Non-professional charging equipment should be used under human supervision.
- Use under professional guidance. Non-professionals are not allowed to use it alone.
- Minors are not allowed to use this device.
- Please make sure the input voltage is correct to avoid accidents.
1.2. Pre-Use Checks
When you receive a new power supply, perform the following checks to ensure proper functionality:
- Check for any damages caused during transportation.
- Verify that all accessories are complete.
- Check if the output voltage and current are normal after turning on the device.
If any problems are found, please contact the merchant immediately.
1.3. Safety Symbols
The following safety symbols may appear in this manual or on the DC power supply:
- ⚠ Attention: Indicates important information or a warning.
- ⚡ High Voltage: Indicates the presence of dangerous voltage levels.
- ⏚ Grounding: Indicates a grounding point.
2. Product Overview
The KUAIQU 5-Digit High Precision DC Lab Power Supply is a professional-grade, industrial-level programmable DC power supply designed for demanding users. It offers precise voltage and current control, advanced protection features, and versatile connectivity.
2.1. Key Features
- 5-Digit High Precision Display: Ultra-precise voltage and current control with 0.001V / 0.001A resolution.
- Dual Curve Display: Visual real-time output voltage and current graphs for better understanding of circuit changes.
- Complete Protection: Includes OCP (Over Current Protection), OVP (Over Voltage Protection), Temperature Control Protection, Overload Protection, and Short Circuit Protection.
- 4 Groups Programmable Memory: Store and recall frequently used settings for quick setup.
- Multi-interfaces: RS485, RS232, and USB for versatile communication and control.
- Dual Fast Charging Ports: USB-A (5V/2A) and USB-C (5V/2A) for convenient device charging.
- Automatic Milliamp Conversion: Current values below 0.1A automatically switch to 0.01mA display.
- Low Ripple Noise: ≤5mV ≤5mA for stable output.
- Encoder Adjustment: Precise digital signal adjustment for voltage and current.
- Output Lock: Locks parameters to prevent accidental changes during operation.
- Output Switch: Dedicated button to enable/disable output.
- Short-Circuit Alarm Prompts: Audible alerts for short-circuit conditions.
- Automatic Constant Voltage & Constant Current: Automatically switches between CV and CC modes based on load.
2.2. Product Video Demonstration
Video: A demonstration of the KUAIQU SPPS-K power supply's hyperbolic function display, showing how to connect a multimeter, adjust voltage and current, and observe real-time power consumption fluctuations on the curve display.
2.3. Core Advantages Over Standard Models
| Feature | Our Premium Power Supply | Standard Market Models |
|---|---|---|
| Display | 5-digit high precision (0.001V/0.001A resolution) | 4-digit basic display (0.01V/0.01A resolution) |
| Protection | Complete OCP/OVP overvoltage/overcurrent protection | Basic or no protection |
| Programmability | 4 groups of programmable memory | No programmable function |
| Interfaces | RS485 + RS232 + USB + USB-C | Only USB or no communication interface |
| Display Function | Voltage/current dual curve real-time display | Only numerical display |
| Grade | Professional laboratory/industrial grade | Consumer-grade for basic use |
Image: A table comparing the features of the Premium Power Supply with standard market models, highlighting superior precision, protection, programmability, interfaces, display functions, and grade.
3. Panel Instruction
Familiarize yourself with the front panel controls and indicators:

Image: Detailed diagram of the product's front panel, labeling the voltage value, current value, power, OVP voltage protection, OCP current protection, Surface Map Button, Smart Storage Button (Memory), Power Switch, USB port, Positive output port, Negative output port, Ground wire, Voltage encoder knob, Lock Button, Output Button, Current encoder knob, and Type-C port.
3.1. Power Button Introduction

Image: Visual guide to the Power Button functions, including how to use the OUTPUT button to start output, the LOCK button to enable lockout and prevent misuse, and the Mute key to turn the buzzer sound on or off by pressing for 5 seconds.
4. Specifications
| Parameter | Value |
|---|---|
| Input Voltage | 110V±10% 60Hz / 220V±10% 50Hz |
| Working Temperature | 0 ℃-40℃; Relative Humidity: <80%RH |
| Storage Temperature | -10 ℃-70℃; Relative Humidity: <70%RH |
| Constant Voltage State | Voltage stability≤0.1%+3mV, Low Voltage:0.2~0.3%+3mV, Load stability≤0.5%+3mV, Ripple noise≤30mVrms |
| Constant Current State | Current stability≤0.2%+3mA, Load stability≤0.2%+3mV, Ripple noise≤20mArms |
| Display Accuracy | 0.5%+2digits |
| Display Resolution | Voltage: 0.001V / Current: 0.001A |
| Product Dimension | 3.3 x 9.4 x 5.9 Inches (Length: 29cm, Width: 21cm, Height: 13cm) |
| Product Weight | 2.6 lb (1.7 kg) |
| Fuse Standard | 5A (AC 110V Input) |
Note: Specific models like SPPS-1306 and SPPS-400 may have varying output ranges (e.g., 0-30V, 0-5A or 0-60V, 0-5A).
4.1. Display Features

Image: A close-up view of the power supply's 5-digit display, emphasizing its high precision with minimum resolutions of 0.001V and 0.01mA.

Image: The power supply's screen displaying real-time voltage and current curves, providing a visual representation of output changes over time. The 'CURVE' button is highlighted for activating this feature.
5. Work Environment
- Working Temperature: 0℃ - 40℃
- Relative Humidity: <80%RH
- Storage Temperature: -10℃ - 70℃
- Relative Humidity: <70%RH
The cooling fan is located at the rear of the device and should have enough space for proper ventilation and cooling. Do not use in an environment where the ambient temperature exceeds 40 degrees Celsius.
6. Setup and Connection
6.1. Connecting the Load
- Rotate the terminal knob by turning it counter-clockwise.
- Insert the load terminal.
- Turn the terminal knob clockwise to secure the connection.
- Banana plugs can be directly inserted into the terminal holes.
⚠ Attention: Improper connection may result in damage to the power supply and the connected load. When connecting a battery load, do not reverse the polarity of the terminals, as this may damage the power supply.
6.2. Power Cord and Plug Types
The power supply supports various plug types. Ensure you use the correct power cord for your region.

Image: Illustrations of common power plug types: EU Plug, UK Plug, AU Plug, and US Plug, indicating the power supply's compatibility.
7. Operating Instructions
7.1. Power On/Off
Press the 'POWER' button to turn on the power supply. The screen will display the status voltage and current. Press the 'POWER' button again to turn it off.
7.2. Voltage Setting
- Press the 'VOLTAGE' encoding switch. The currently set digit will flash as a prompt.
- Rotate the knob clockwise to increase the value, counter-clockwise to decrease the value.
- Press the encoding switch to move the cursor position.
- After 5 seconds of completing the voltage setting operation, the flashing stops.
7.3. Current Setting
- Press the 'CURRENT' encoding switch. The currently set digit will flash as a prompt.
- Rotate the knob clockwise to increase the value, counter-clockwise to decrease the value.
- Press the encoding switch to move the cursor position.
- After 5 seconds of completing the current setting operation, the flashing stops.

Image: A visual guide demonstrating the use of the encoder knob for precise voltage and current adjustments, showing how to click the knob to toggle digit position and rotate to change values.
7.4. Output Switch
After presetting the voltage and current values, press the 'OUTPUT' button to start the output. The output button light will turn on. Press the output button again to turn off the output and the light.
7.5. Constant Voltage / Constant Current Characteristics
This power supply automatically converts between constant voltage (CV) and constant current (CC) states based on load changes. The intersection between these modes is the conversion point. The CV indicator light is on during constant voltage operation, and the CC indicator is on during constant current operation.
⚠ Attention: In actual CV operation, if the load resistance decreases and the output current increases to the set current value, the power supply will automatically switch to CC mode. When the load resistance increases, the current will remain stable, and the voltage will increase proportionally. If the load resistance continues to increase, the output voltage will reach the set value, and the power supply will switch back to CV mode.
7.6. Curve Display Function
Press the 'CURVE' button to enter the real-time voltage and current adjustment curve interface. The curves will only be displayed when the 'OUTPUT' button is turned on. The output power time will be displayed at the top of the screen, and the voltage and current on this screen will be updated to maintain the curve chart for more than 10 seconds. Press the 'CURVE' button again to exit.
7.7. Front Panel Locking
Press the 'LOCK' button to turn on the button light and lock all button and knob operations on the screen. To unlock, press the 'LOCK' button again; the button light will turn off.
7.8. Mute Key Usage
Press and hold the 'LOCK' key for about 5 seconds to turn on or off the buzzer sound. This is useful in noisy industrial environments or lab settings that require quiet operation.
8. Memory Function
The power supply has four sets of internal storage for voltage and current settings: M1, M2, M3, and M4. There is also a temporary storage (M0) for values not saved in the four groups.

Image: The power supply's display showing the intelligent four-group storage function, with preset voltage and current values for different applications like circuit board repair, battery charging, LED light testing, and laboratory/teaching.
8.1. Storing Settings
- Press the 'Memory' button to enter the intelligent storage interface.
- Rotate the 'VOLTAGE' or 'CURRENT' knob to select one of the storage items (M1, M2, M3, or M4) where the gray light bar appears.
- Press and hold the 'VOLTAGE' or 'CURRENT' switch to enter the desired voltage and current values.
- After adjusting, long press the 'VOLTAGE' or 'CURRENT' knob again to save the settings. The stored values will be saved, and the M symbol of the previously called storage will be displayed in the upper left corner of the screen.
8.2. Recalling Settings
This power supply can directly call any of the four sets of internal storage. If using voltage and current settings other than the four stored values, they will automatically display as temporary storage (M0). The M symbol displayed in the upper left corner of the screen represents the storage and current group being called.
- Press the 'Memory' key to enter the intelligent storage interface.
- Rotate the 'VOLTAGE' or 'CURRENT' knob to select a set (M1, M2, M3, or M4) where the gray light bar appears.
- Press the 'VOLTAGE' or 'CURRENT' switch again to recall the stored values. The M symbol for this group will appear in the upper left corner of the screen.
9. Protection Features
The KUAIQU power supply is equipped with comprehensive protection mechanisms to ensure safety and prevent damage to both the device and connected loads.

Image: A visual explanation of the power supply's full protection features, including OCP (Current Limit), OVP (Voltage Limit), Temperature Control, Overload, and Short Circuit Protection, along with their respective warning displays.
9.1. OCP (Over Current Protection)
Click the 'OCP' button to enable or disable the OCP function. Long press the 'OCP' button to enter the OCP setting state. Adjust the current value using the current knob (rotate clockwise or counter-clockwise, press to move the cursor) to set the OCP current value. If you long press the current adjustment knob, the OCP value will be saved. If you short press the OCP button, the current OCP value will not be saved.
When OCP is enabled and an overcurrent condition occurs, an alarm will be triggered, and the machine will stop outputting, effectively protecting the external load. To clear the alarm, short press the 'OUTPUT' button.
9.2. OVP (Over Voltage Protection)
Click the 'OVP' button to enable or disable the OVP function. Long press the 'OVP' button to enter the OVP setting state. Adjust the voltage value using the voltage adjustment knob (rotate to adjust, press to move the cursor) to set the OVP voltage value. If you long press the voltage adjustment knob, the OVP voltage will be saved. If you short press the OVP button, the OVP voltage value will not be saved.
When OVP is enabled and the load voltage exceeds the set voltage, the machine will stop outputting and issue an alarm, effectively protecting the external load. To clear the alarm, short press the 'OUTPUT' button.
9.3. Load Short-Circuit Protection
When the machine detects a short circuit, it will stop output and give an alarm to effectively protect the external load.
10. Dual Fast Charging Ports
The power supply comes with dual USB output ports (USB-A 5V/2A and USB-C 5V/2A). These ports are not affected by voltage and current regulation and can be used for charging devices independently. When used separately, they support fast charging.

Image: The power supply demonstrating its dual interface multifunctional charging capability, with a laptop connected to the USB-A port and a smartphone to the USB-C port.
11. Product Maintenance
- Disconnect the power when the product is not in use.
- Unplug the power supply before cleaning.
- Do not use hydrocarbons, chlorides, or similar solvents, or abrasive cleaners.
12. Fuse Replacement
If the fuse blows, the power supply will stop working. To find and correct the cause of the blown fuse, then replace it with a fuse of the same specification.
⚠ For effective safety protection, it is only necessary to replace the fuse of a specific specification. Before replacing the fuse, the power must be turned off and the power cord must be unplugged from the power outlet.
13. User Tips
No specific user tips were provided in the available reviews or Q&A content.
14. Warranty and Support
14.1. Product Warranty
This product is offered free maintenance service within one year from the date of purchase. Exceptions to this warranty include:
- Lack of this product warranty card.
- Failures caused by improper use, such as improper handling, repair, modification, or adjustment of the device.
- Consumable materials are not covered by the warranty.
- Damage due to naturally irresistible disasters such as floods, fires, earthquakes, etc.
Maintenance costs are charged for repairs that exceed the warranty period, and the costs incurred for maintenance are the responsibility of the user.
14.2. Contact Information
Company: Shenzhen Kuaiqu Electronic Co. LtdAddress: West 4th Floor, Block 5, Jewel Innovation Industry Base, No. 53 Pingxin North Road, Pinghu, Longgang District, Shenzhen, China
Website: www.nice-power.com.cn
Email: szkuaiqu@gmail.com
Phone: +8610925402565, +8675525876505
Whatsapp: +8619025402565
Wechat: +8819925402588
15. Packing List
The following items are included in your product package:
- 1x KUAIQU DC Power Supply
- 1x Power Cord
- 1x Output Load Cord (Selection based on model)
- 1x USB Cable (Selection based on model)
- 1x User's Manual
- 1x Warranty Card

Image: A visual representation of the product accessory list, featuring the power supply unit, power cord, output load cables, and a user manual, for a 0-30V 0-5A model with RS232/485/USB port options.