1. Introduction

The CERTEON R2100E Industrial Paperless Recorder is a panel-mounted data logging instrument designed for real-time monitoring and recording of industrial process parameters. It supports up to four universal input channels and provides data storage, relay alarm output, and RS485 Modbus RTU communication. This device is suitable for applications requiring continuous process monitoring and historical data analysis.

Note: The display interface is available in Chinese only. No English language option is provided for the device's display.

Front view of the R2100E Paperless Recorder showing a digital display with 'Flow 18.12 Kg/h'.
Figure 1: CERTEON R2100E Industrial Paperless Recorder

2. Specifications

The R2100E Paperless Recorder offers robust features for industrial data acquisition:

Detailed product specifications for the R2100E, including display, housing, processor, storage, input channels, and communication ports.
Figure 2: R2100E Product Specifications

General Specifications

Parameter Specification
Power Supply AC 220V (50Hz) or 24VDC (18-36VDC), optional 12VDC (9-18VDC)
Input Channels 1-4 selectable universal inputs (Voltage, Current, Resistance, RTD, Thermocouple)
Output (Standard) RS485 (Modbus RTU) + 2 Relay Outputs
Custom Output Options 4-20mA analog output and up to 4 relay outputs
Display 3-inch Monochrome LCD (128x64 Dot Matrix)
Storage Capacity 128 MB internal memory (NAND FLASH for historical data, Serial FRAM for configuration)
Dimensions 160 × 80 mm
USB Interface Supported (for data export, USB 1.1-2.0, 1G-32G U disk compatible)
Power Feed Output 1 × 24V DC feed output
Alarm Interval Adjustable from 1 to 240 seconds (11 levels available)
Protection Rating IP65 (front panel)
Processor High-performance 32-bit ARM Cortex-M3 RISC core
Operating Temperature 0 – 50 °C (Avoid direct sunlight)
Humidity 0 – 85% R.H. (No Condensation)
Altitude <2000m (unless otherwise specified)
Net Weight ≤ 1.0kg

Key Features

  • Flexible Multi-Channel Input: Supports 1 to 4 input channels for a wide range of monitoring needs.
  • High-Speed RISC Processor: Ensures stable and real-time data processing performance.
  • Multiple Display Modes: View data in curves, digital values, or bar charts—switch modes as needed.
  • USB Data Transfer: Easily export data via USB and print curve reports or data logs.
  • Relay Output + 24V Power Feed: Comes with 2 relay outputs and 1× 24V power feed by default; 4 relay channels optional.
  • IP65-Rated Terminal Protection: Isolated terminals and dustproof plugs ensure safety against moisture, dust, fire, and static.
  • Compact Design with Clear LCD: 3-inch LCD screen delivers crisp visuals in a space-saving form factor.
Icons representing key features: 4-Channel Alarm, High Cost Performance, Recording Interval Setting, Multiple Data Display, RISC Core Processor, Linear Transformer.
Figure 3: Key Features Overview

3. Setup and Installation

Ensure installation is performed by qualified personnel.

Panel Installation

  1. Install the recorder into a compatible panel opening of 152.00 (+1, -0) mm by 76.00 (+1, -0) mm. The overall dimensions of the unit are 160 × 80 mm.
Diagram showing product dimensions and panel cutout sizes for single and grouped units. Single unit panel cutout size is 152.00 (+1, -0) mm by 76.00 (+1, -0) mm.
Figure 4: Product Dimensions and Panel Cutout

Wiring Instructions

WARNING! Risk of electric shock. Internal circuits operate at hazardous voltage levels. Disconnect power supply before installation, maintenance, or wiring.

  1. Ensure the supply voltage is AC 220 V and properly grounded. Confirm that the power supply matches AC 220 V before connection.
  2. Connect input signals to the designated terminals according to wiring requirements.
  3. Connect RS485 communication lines if remote monitoring is required.
  4. Verify relay wiring before energizing the system.
  5. Ensure correct polarity and terminal assignment to prevent damage.
  6. Do not insert or remove wiring while the device is powered.
  7. Use only properly rated cables and connectors.
  8. If using the 24 V feed output, ensure the connected load does not exceed the rated capacity.
Wiring diagram showing connections for Thermocouple Input (2-Wire System), RTD Input (2-Wire / 3-Wire System), Voltage Wiring, and Current Wiring. Notes on compensating wires, equal resistance for RTD, and support for 2, 3, and 4-wire configurations for voltage/current signals are included.
Figure 5: Input Wiring Diagrams
Rear view of the R2100E recorder with labels for Serial Port, RJ45 Port, Power Wiring, Side Ventilation Holes, and Wiring Terminals.
Figure 6: Rear Panel and Wiring Terminals

4. Operation

Basic Operation

  1. Power on the device after confirming all wiring connections are secure.
  2. Select the required input channel configuration within the system settings.
  3. Configure alarm thresholds, relay outputs, and communication parameters as needed.
  4. Insert a compatible USB storage device to enable data export when required.
Front view of the R2100E recorder with labels pointing to the USB Port, Navigation Keys, Silicone Buttons, Confirm Key, Exit Key, Menu Key, and the 128x64 Dot Matrix Monochrome LCD Display.
Figure 7: Instrument Appearance and Controls

Data Reading and Display Modes

Process values can be viewed in various display modes:

  • Curve Mode: Displays data trends over time.
  • Digital Display Mode: Shows real-time numerical values.
  • Bar Graph Mode: Provides a visual representation of data levels.

Historical data can be exported via the USB interface for report generation and analysis. Relay outputs will activate automatically according to configured alarm conditions.

Screenshots of the R2100E display showing different modes: curve, numeric, and bar graph interfaces with customizable layouts.
Figure 8: Multiple Display Modes

Product Demonstration Video

Video 1: A short demonstration of the R2100E Paperless Recorder's display and basic functionality.

5. Storage and Maintenance

  1. Disconnect power before cleaning.
  2. Clean the front panel using a soft, dry cloth. Do not use solvents or abrasive cleaners.
  3. Store the device in a dry and dust-free environment when not in use.
  4. Periodically inspect terminal connections for looseness or corrosion.
  5. Back up stored data regularly to prevent accidental loss.

6. Troubleshooting

This section provides guidance for common issues. For complex problems, please contact technical support.

  • No Power: Ensure the AC 220V power supply is connected correctly and the device is properly grounded. Check all power connections.
  • No Data Display: Verify input signals are connected to the correct terminals and that sensors are functioning. Check input channel configuration in system settings.
  • Incorrect Readings: Confirm sensor calibration and input type settings. Ensure correct polarity and terminal assignment for all connections.
  • USB Data Transfer Issues: Ensure a compatible USB storage device (1G-32G U disk recommended) is inserted correctly.
  • Relay Alarms Not Activating: Check configured alarm thresholds and relay output settings. Verify relay wiring.

7. User Tips

  • Stable Data Recording: For optimal performance and clear, stable data recording, ensure the unit is securely installed in your control panel and all wiring is firm.
  • Customization: If your application requires more than the standard 2 relay outputs, remember that a 4-channel relay output option is available upon request.
  • Data Management: Utilize the USB port for easy data transfer and report printing. Regularly export historical data to prevent loss and facilitate analysis.
  • Power Compatibility: The device operates on AC220V and provides a 24V feed output. Always confirm your power source matches these specifications before connection.

8. Safety Precautions

WARNING! Risk of electric shock. Internal circuits operate at hazardous voltage levels. Disconnect power supply before installation, maintenance, or wiring.

  • Ensure installation is performed by qualified personnel.
  • Confirm that the power supply matches AC 220 V before connection.
  • Do not operate the device in environments exceeding its specified temperature or humidity limits.
  • Avoid exposure to corrosive gases or conductive dust.
  • Ensure correct polarity and terminal assignment to prevent damage.
  • Do not insert or remove wiring while the device is powered.
  • Use only properly rated cables and connectors.
  • If using the 24 V feed output, ensure the connected load does not exceed the rated capacity.
  • Do not use the device in explosive atmospheres unless certified for such use.
  • Keep out of reach of children.
  • Proper disposal: Follow WEEE Directive requirements for electronic waste disposal.

Note: The above warning information is for reference only. Final warning language must comply with the official language requirements of the destination EU country.

9. Warranty and Support

For technical assistance, inquiries, or support regarding your CERTEON R2100E Industrial Paperless Recorder, please contact the seller directly.

A detailed user manual in PDF format is available for download. Please refer to the product page for the link: R2100E User Manual (PDF)

Contact Information:

Contact information for CERTEON, including WhatsApp number: +86-19542723588 and Email: celiachen008@gmail.com, along with a QR code.
Figure 9: Seller Contact Details

WhatsApp: +86-19542723588

Email: celiachen008@gmail.com

This document is provided for product instruction purposes only. It does not constitute legal advice. The seller is responsible for ensuring compliance with destination market regulations, including CE marking, EMC Directive, and Low Voltage Directive where applicable.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.