1. Product Overview
This manual provides essential information for the safe and efficient use of your Erilles POE Power Injector. It is designed for power supply and data transmission to POE-compliant devices such as IP cameras, wireless APs, and IP phones in indoor environments.
Compliance: IEEE 802.3af/at, FCC Part 15B, CE EN 55032/55035
1.1 Key Features
- Auto-detects POE-compliant devices; prevents power supply to non-POE equipment to avoid damage.
- Integrated power & data transmission; a single cable simplifies wiring.
- Multiple protections: overcurrent, overvoltage, short circuit, overheating, reverse polarity.
- LED indicators for real-time monitoring of power and port status.
- Wide voltage input (AC 100-240V) adapts to global power grids; high conversion efficiency.
- System reliability: MTBF > 100,000 hours.
- Anti-thunder design, bearing positive and passive 5KB, 8/20uS electric shockwave up to 5 times per minute.
- Failure alert function and FUSE.
2. Specifications
| Item | Specification |
|---|---|
| Input Voltage | AC 100-240V 50/60Hz (Wide Voltage) |
| Input Current | 100V-240V AC, 47-63Hz |
| Max Input Power | 12-24W |
| POE Output Voltage | DC 48V ±0.5V (PoE Standard) / DC 24V ±0.5V (PoE Standard) |
| Single Port POE Power | 24W (802.3af) / 24W (802.3at) |
| Total POE Output Power | 24W |
| POE Ports | 2 × RJ45 (10/100/1000Mbps Auto-Negotiation) |
| Transmission Distance | ≤100m (Cat5e/Cat6 UTP Cable, 8-Core Full Connection) |
| Operating Temperature | 0°C ~ 45°C |
| Operating Humidity | 10% ~ 90% RH (Non-condensing) |
| Protection Grade | IP20 (Indoor Only) |
| Input Stabilivolt Accuracy | -24V DC±2% |
| Load Adjustment Rate | -24V DC±2% |
| DC Output Broadband Noise Voltage | 3.4kHz-150kHz≤50m |
2.1 POE Power Protection
- Output Overvoltage Protection: -52V ~ -50V DC
- Overcurrent Protection (single circuit): 500mA ~ 1000mA
- Input Overvoltage Protection: Input Voltage > 290V-310V AC (Recovery Point: > 240V AC)
- Input Undervoltage Protection: Input Voltage < 140V-155V AC (Recovery Point: < 100V AC)
- Temperature Protection: >100℃
3. Installation and Setup
3.1 Pre-Installation Preparation
- Inspect the product for any cracks, loose parts, or damage. Confirm all accessories (power cord, mounting screws) are complete.
- Ensure terminal devices comply with IEEE 802.3af/at standards, and their rated power does not exceed the single-port POE power capacity of this injector.
- Prepare Cat5e/Cat6 8-core UTP cables (T568A/T568B standard) with firmly crimped crystal heads.
- Use a grounded AC socket to ensure electrical safety.
3.2 Installation Steps
- Fix the device using the mounting holes (suitable for wall or rack mounting). Ensure at least 10cm of space is reserved around the device for proper heat dissipation.
- Connect one end of an Ethernet cable to the POE port of the power supply. Insert the other end into the network port of your terminal device until it clicks securely.
- Plug the power cord into the power input port of the injector and then into a grounded AC socket.
- Turn on the power switch. Verify that the LED indicators illuminate to confirm normal operation.
4. Operation
4.1 Power On/Off
- Power On: Turn on the switch. The green PWR LED will light up, indicating normal power input.
- Power Off: Turn off the switch first, then unplug the power cord and network cables. Avoid hot-plugging to prevent damage.
4.2 LED Indicator Guide
| Indicator | Status | Description |
|---|---|---|
| PWR (Green) | On | Power input is normal. |
| PWR (Green) | Off | No power or power supply fault. |
| PoE Port (Green) | On | POE power supply and data transmission normal. |
| PoE Port (Green) | Flashing | Data transmission only; no POE power supply. |
| PoE Port (Green) | Off | No power, or connected to non-POE device. |
| Indicator Light | Off | Short circuit or overload protection, consumer power too high, consumer breakdown, or cable short circuit. |
5. Safety Precautions
Warning: Failure to follow these precautions may cause fire, electric shock, or device damage.
- Use only AC 100-240V power supply. Do not use DC power or mismatched voltage.
- For indoor use only. Keep away from humidity, dust, corrosive gas, and water splashes.
- Always use a grounded socket to prevent electric shock. Do not remove the ground pin from the power plug.
- Do not disassemble, modify, or splice the device. Internal high-voltage components pose serious risks.
- Do not overload ports. The total power consumption of connected devices must be less than the total POE output power.
- Keep heat dissipation vents unobstructed. Avoid placing the device near high-temperature objects or fire sources.
- Unplug the power cord during thunderstorms to avoid lightning-induced damage.
- Keep out of reach of children. Small parts may cause choking hazards.
- Stop use immediately if smoke, odor, or abnormal heat occurs. Cut off power and contact after-sales support.
6. Maintenance & Troubleshooting
6.1 Daily Maintenance
- Clean the device only when it is powered off. Wipe the surface with a dry, lint-free cloth. Do not use liquid cleaners or corrosive solvents.
- Regularly check power cords, network cables, and crystal heads for damage. Replace faulty parts promptly.
- Store the device in a dry, cool, well-ventilated place when not in use. Disconnect all connections.
6.2 Troubleshooting
| Fault Phenomenon | Possible Cause | Solution |
|---|---|---|
| PWR LED off | Power cord loose; socket no power; switch faulty. | Replug the power cord; test the socket; contact after-sales for switch repair. |
| PoE port LED off; terminal no power | Non-POE device; faulty cable; crystal head loose. | Replace with POE device; use Cat5e/Cat6 cable; re-crimp crystal head. |
| Data transmission failure | Cable over 100m; IP conflict; cable interference. | Shorten cable length; adjust device IP; keep cable away from high-voltage lines. |
| Device overheats; ports power off | Vents blocked; overload; ambient temp too high. | Clear obstacles; reduce connected devices; move to cooler environment. |
7. User Tips
- Power Cable: While some product images may show a power cable, always verify the package contents upon arrival. If a power cable is not included, ensure you have a compatible AC power cord for the injector's input.
- Cable Quality: For optimal performance and to avoid data transmission issues, use high-quality Cat5e or Cat6 Ethernet cables, especially for runs approaching the 100m limit.
- Environmental Considerations: Place the injector in a location with good airflow to prevent overheating, which can lead to performance degradation or device shutdown.
8. Warranty & Support
Warranty Period: [XX] years from the date of purchase (please retain your invoice as proof of purchase).
Warranty Scope: Free repair/replacement for manufacturing defects. This warranty excludes damage resulting from misuse, unauthorized disassembly, or natural disasters.
After-Sales Contact:
- Telephone: [XX]
- Email: [XX]
- Website: [XX]
Compliance Statement: This product complies with the essential requirements of Directive 2014/30/EU (EMC) and Directive 2011/65/EU (RoHS). The full declaration of conformity is available on the official website.
*The company reserves the right to modify specifications without prior notice. For the latest version, refer to the official website.
(Note: Some parts of this document may have been generated by AI.)
For a downloadable PDF version of this user manual, please refer to the official product page documentation.